R&S®R-Line Compact Test Chamber

Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

本製品の製造は終了しています
詳細をご希望の方はこちらまでお問い合わせください。
  • 概要

Key Facts

  • Wide frequency range from 800 MHz to 18 GHz
  • Measurement of radiated spurious emissions (RSE), e.g. according to 3GPP TS 51.010 and ETSI 301 908-1 with R&S®EMC32 software

Brief Description

The R&S®R-LINE Compact Test Chamber compact test chamber assists in eliminating emission problems and optimizing the RF performance of wireless terminals already in the initial phases of development.

Features Collapsed

  • Reduced time to market through early verification of radiated emissions
  • Efficient operation through measurements in the lab
  • Optimum utilization of resources through comprehensive, automated test sequences

Specifications

Environmental conditions
Operating temperature range +0°C to +35°C
Storage temperature range –10°C to +45°C

Supported Technologies

  • Cellular Standards
  • Wireless Standards
  • Satellite Navigation

Key Facts

  • Wide frequency range from 800 MHz to 18 GHz
  • Measurement of radiated spurious emissions (RSE), e.g. according to 3GPP TS 51.010 and ETSI 301 908-1 with R&S®EMC32 software
  • Measurement of the over-the-air (OTA) performance with R&S®AMS32 software
  • Measurement accuracy as high as in an anechoic chamber at significantly reduced investments in equipment and infrastructure
  • Compact size suitable for any R&D lab environment
  • Efficient through measurements with automated 3D positioner

Brief Description

The R&S®R-LINE Compact Test Chamber compact test chamber assists in eliminating emission problems and optimizing the RF performance of wireless terminals already in the initial phases of development. This helps to avoid costly and time-consuming modifications to a large number of prototypes at a later stage, thus optimizing time to market and return on investment.

The R&S®R-Line compact RF chamber performs accurate radiated measurements with a high correlation compared to larger anechoic chambers.

Features & Benefits

  • Reduced time to market through early verification of radiated emissions
    • Measurement accuracy as high as in an anechoic chamber
    • Meets site VSWR (SVSWR) in line with CISPR 16-1-4:2007
    • Frequency range 800 MHz to 18 GHz
  • Efficient operation through measurements in the lab
    • Compact and versatile
    • Readily available verification tool
    • Significantly lower investment than for anechoic chamber
  • Optimum utilization of resources through comprehensive, automated test sequences

    Automated measurements using turnkey solutions that combine the R&S®R-Line with Rohde & Schwarz test systems

    • R&S®TS8991 Over The Air Performance (OTA) Test System
    • R&S®TS8996 Radiated Spurious Emissions (RSE) Test System

Specifications

General data
Environmental conditions
Operating temperature range +0°C to +35°C
Storage temperature range –10°C to +45°C
Relative humidity without condensation 90 % at +40 °C, non-condensing
Power supply 208 V to 230 V/50 Hz to 60 Hz max. 350 VA
Environmental test
Electromagnetic compatibility EU – EMC Directive 2004/108/EC in line with EN 61326-1, EN 55011 (class B),
EN 61000-3-2, EN 61000-3-3
Electrical safety EU – Low Voltage Directive 2006/95/EC in line with EN 61010-1
Mechanical data
Dimensions (W × H × D) including four movable and lockable castors 1700 mm × 2250 mm × 1640 mm
(66.93 in × 88.58 in × 64.57 in)
Weight 562 kg (1239 lb)
Door size (W × H) 500 mm × 1000 mm
19.68 in × 39.37 in
Size of EUT (∅ × H) max. 330 mm × 240 mm
max. 12.99 in × 9.45 in
Weight of EUT max. 1 kg (max. 2.2 lb)
Positioning speed of turntable azimuth: 0.5 rpm to 10 rpm
elevation: 0.2 rpm to 10 rpm
Distance between test antenna and center of EUT 1.03 m (40.55 in)
Interfaces Data
IEC/IEEE bus, RS-232-C alternatively for control of positioner in line with IEC 625-2 (IEEE 488.2)
Test antenna 2 × SMA (female)
Communications antenna 1 × N (female)
RF feedthroughs for calibration or connecting the EUT 2 × N (female)
2 × SMA (female)
RF specifications
Measurement range
Frequency range 800 MHz to 18 GHz
Polarization horizontal and vertical, through ¸R&S®HL024A1 cross-polarized antenna
RF power max. 3 W
Communications antenna 800 MHz to 6 GHz, circularly polarized
Field uniformity site VSWR, typ. 2 dB in line with CISPR 16-1-4:2007
Shielding effectiveness > 95 dB 800 MHz to 6 GHz
> 70 dB 6 GHz to 18 GHz

Supported Technologies

  • Cellular Standards
    • WCDMA/HSPA/HSPA+
    • WCDMA-3GPP FDD
    • WCDMA-3GPP TDD
    • LTE
    • GSM/GPRS/EDGE/EDGE Evolution
    • CDMA2000® 1xEV-DO
    • CDMA2000® 1xRTT
    • TD-SCDMA
    • GSM-R
    • cdmaONE
    • IS-136
  • Wireless Standards
    • WiMAX IEEE 802.16e-2005 and IEEE 802.16-2004
    • WLAN IEEE 802.11 a/b/g
  • Satellite Navigation
    • Bluetooth® (Basic Rate)
    • GPS
ありがとうございます。

リクエストは正常に送信されました。

当社より追ってご連絡いたします。

ローデ・シュワルツ・チーム

デモを取得する

質問を入力してください。
お名前(ファースト・ネーム)を入力してください。
質問を入力してください。
有効な電子メール・アドレスを入力してください。
会社名を入力してください。
市区町村名を入力してください。
郵便番号を入力してください。

国名を入力してください。
マーケティング・パーミッション

次の手段によってローデ・シュワルツから情報を受信することを希望します。


詳細について

私は、このウェブサイトの出版物に記載されているRohde & Schwarz GmbH & Co. KGおよびRohde & Schwarzの法人および子会社が、
ここで選択した手段 (電子メールまたは郵便メール) を通じて、マーケティングおよび広告目的 (特別キャンペーンや値引きに関する情報など) で、私に連絡することに同意します。その内容は、電子計測、セキュリティ通信、モニタリングおよびネットワークテスト、放送およびメディア、そしてサイバーセキュリティ分野の製品やソリューションを含みますが、上記に限定されるものではありません。

お客様の権利

この同意表明は、件名が"Unsubscribe"の電子メールをnews@rohde-schwarz.com宛に送信することにより、いつでも取り消すことができます。これに加えて、今後の電子メール広告の購読を停止するためのリンクが、送信されるすべての電子メールに記載されています。個人データの使用と取り消し手順の詳細は、「プライバシーステートメント」に記載されています。

画像に表示されている文字を入力してください。
show captcha
入力内容が正しくありません。
Do not enter data in this field
ありがとうございます。

リクエストは正常に送信されました。

当社より追ってご連絡いたします。

ローデ・シュワルツ・チーム

見積りを取得する

質問を入力してください。
お名前(ファースト・ネーム)を入力してください。
質問を入力してください。
有効な電子メール・アドレスを入力してください。
会社名を入力してください。
市区町村名を入力してください。
郵便番号を入力してください。
電話番号を入力してください。

国名を入力してください。
マーケティング・パーミッション

次の手段によってローデ・シュワルツから情報を受信することを希望します。


詳細について

私は、このウェブサイトの出版物に記載されているRohde & Schwarz GmbH & Co. KGおよびRohde & Schwarzの法人および子会社が、
ここで選択した手段 (電子メールまたは郵便メール) を通じて、マーケティングおよび広告目的 (特別キャンペーンや値引きに関する情報など) で、私に連絡することに同意します。その内容は、電子計測、セキュリティ通信、モニタリングおよびネットワークテスト、放送およびメディア、そしてサイバーセキュリティ分野の製品やソリューションを含みますが、上記に限定されるものではありません。

お客様の権利

この同意表明は、件名が"Unsubscribe"の電子メールをnews@rohde-schwarz.com宛に送信することにより、いつでも取り消すことができます。これに加えて、今後の電子メール広告の購読を停止するためのリンクが、送信されるすべての電子メールに記載されています。個人データの使用と取り消し手順の詳細は、「プライバシーステートメント」に記載されています。

画像に表示されている文字を入力してください。
show captcha
入力内容が正しくありません。
Do not enter data in this field
ありがとうございます。

リクエストは正常に送信されました。

当社より追ってご連絡いたします。

ローデ・シュワルツ・チーム

お問い合わせ

質問を入力してください。
お名前(ファースト・ネーム)を入力してください。
質問を入力してください。
有効な電子メール・アドレスを入力してください。
会社名を入力してください。
市区町村名を入力してください。
郵便番号を入力してください。

国名を入力してください。
マーケティング・パーミッション

次の手段によってローデ・シュワルツから情報を受信することを希望します。


詳細について

私は、このウェブサイトの出版物に記載されているRohde & Schwarz GmbH & Co. KGおよびRohde & Schwarzの法人および子会社が、
ここで選択した手段 (電子メールまたは郵便メール) を通じて、マーケティングおよび広告目的 (特別キャンペーンや値引きに関する情報など) で、私に連絡することに同意します。その内容は、電子計測、セキュリティ通信、モニタリングおよびネットワークテスト、放送およびメディア、そしてサイバーセキュリティ分野の製品やソリューションを含みますが、上記に限定されるものではありません。

お客様の権利

この同意表明は、件名が"Unsubscribe"の電子メールをnews@rohde-schwarz.com宛に送信することにより、いつでも取り消すことができます。これに加えて、今後の電子メール広告の購読を停止するためのリンクが、送信されるすべての電子メールに記載されています。個人データの使用と取り消し手順の詳細は、「プライバシーステートメント」に記載されています。

画像に表示されている文字を入力してください。
show captcha
入力内容が正しくありません。
Do not enter data in this field
International Website