R&S®NRP-Z8x wideband power sensors

R&S®NRP-Z8x wideband power sensors
라이트박스 열기
R&S®NRP-Z8x wideband power sensors
라이트박스 열기
R&S®NRP-Z8x wideband power sensors
라이트박스 열기
R&S®NRP-Z8x wideband power sensors R&S®NRP-Z8x wideband power sensors R&S®NRP-Z8x wideband power sensors

Key facts

  • Outstanding dynamic range and accuracy
  • High resolution mode
  • Highest measurement speed
  • Automatic pulse analysis
  • Statistical analysis
  • 3 year warranty

Ideal power sensor for radar applications

The R&S®NRP-Z81 wideband power sensors are ideal for radar applications. In development or during installation and maintenance, pulse characteristics as well as output power have to be measured. Similar measurements are required in the production of radar systems and radar components. Thanks to a maximum video bandwidth of 30 MHz and a rise/fall time of < 13 ns, the sensors can measure pulses with a pulse width as small as 50 ns. Key pulse parameters are determined automatically to simplify the measurement and prevent operating errors. By increasing the sampling rate, the high-resolution mode for repetitive signals permits the display of strongly magnified signal sections.

기능 및 장점

High resolution mode

Achieve a time resolution of up to 100 ps

Some applications require the display of strongly magnified signal sections such as the rising edge of a pulse. To improve the graphical display in the trace mode, which has a resolution of 12.5 ns, a high density of samples is required. Equivalent time sampling with repetitive signals can achieve a time resolution of up to 100 ps.

R&amp;S®NRP-Z8x wideband power sensors
라이트박스 열기

Test setup with NRP-Z8x and NRX

Automatic pulse analysis

Ideal with R&S®NRX

Automatic pulse analysis supports users in measuring important pulse parameters, eliminating the need for complex measurements using markers. Changes in the pulse shape are immediately taken into account in the measurement results.

  • Time parameters: rise/fall time, start/stop time, pulse width, duty cycle, pulse period, pulse-off time
  • Level parameters: pulse top, pulse base, peak, average, minimum, overshoot (positive and negative)
R&amp;S®NRP-Z8x wideband power sensors
라이트박스 열기

Time parameters

Ideal for radar applications

Analyze pulsed and modulated signals

The R&S®NRP-Z8x wideband power sensors are perfect for analyzing pulsed and/or modulated signals. Due to their high sampling rate of 80 Msample/s, the power envelope of radar pulses can be reconstructed with a time resolution of 12.5 ns. The sensors’ automatic pulse analysis function makes it possible to measure 15 important pulse parameters automatically, which significantly simplifies and speeds up testing.

R&amp;S®NRP-Z8x wideband power sensors
라이트박스 열기

Radar application measurement with NRP-Z81

Statistical analysis

Statistical analysis of the amplitude distribution

The R&S®NRP-Z8x wideband power sensors permit statistical analysis of the amplitude distribution of noise-like signals to determine key parameters such as peak envelope power, average power and peak-to-average power ratio. A measurement of the CCDF, CDF or PDF using one million samples can be performed by the R&S®NRP-Z8x wideband power sensors in less than 25 ms at full video bandwidth.

Trigger master mode

with base unit or R&S®NRP-Z5

Combined with the R&S®NRX base unit or the R&S®NRP-Z5 sensor hub, an R&S®NRP-Z8x wideband power sensor can be used as a trigger source. In the trigger master mode, a trigger signal is derived from the measured signal inside the power sensor and forwarded to the base unit or sensor hub for further use. All other connected sensors can be externally triggered using this trigger signal.

R&amp;S®NRP-Z8x wideband power sensors
라이트박스 열기

Operation with R&S®NRP-Z5

Available models
Product name
Frequency range
Level range
Connector type
R&S®NRPZ81

Order number 1137.9009.02

Frequency range
50 MHz - 18 GHz
Level range
-60 dBm - +20 dBm
Connector type
N (m)
R&S®NRPZ85

Order number 1411.7501.02

Frequency range
50 MHz - 40 GHz
Level range
-60 dBm - +20 dBm
Connector type
2.92 mm (m)
R&S®NRPZ86

Order number 1417.0109.40

Frequency range
50 MHz - 40 GHz
Level range
-60 dBm - +20 dBm
Connector type
2.4 mm (m)
R&S®NRP-Z86 model .44

Order number 1417.0109.44

Frequency range
50 MHz - 44 GHz
Level range
-60 dBm - +20 dBm
Connector type
2.4 mm (m)

사용 가능한 옵션

Cables and adapters
산물
설명
R&S®NRP-Z2

주문 번호 1146.6750.03 / 1146.6750.05 / 1146.6750.10 / 1146.6750.15

설명
Sensor Extension Cable
R&S®NRP-Z4

주문 번호 1146.8001.02 / 1146.8001.04 / 1146.8001.06 / 1146.8001.11

설명
USB Adapter (passive)
For all R&S®NRP-Z sensors. The R&S®NRPZ4 passive USB adapter provides all basic functions, as it handles the transmission of settings and measurement data as well as the power supply of the sensor via the USB bus. Available cable lengths: Available cable lengths: 2.0m, 0.5m and 0.15m Available cable length for panel-mount: 1m
Interface accessories
산물
설명
NRP-Z5_Sensor_Hub_front.jpg
R&S®NRP-Z5

주문 번호 1146.7740.02

설명
USB sensor hub
R&S®NRP-Z5 can host up to 4 R&S®NRPxxS(N), R&S®NRPxxT(N), R&S®NRPxxA(N) or R&S®NRP-Z sensors. A professional trigger solution allows simultaneous internal and external triggering of all connected sensors.
Documentation
산물
설명
R&S®DCV-1

주문 번호 0240.2187.06

설명
Documentation of calibration values
R&S®DCV-ZP

주문 번호 1173.6506.02

설명
Printout of DCV

정보 요청

질문이 있거나 추가 정보가 필요하십니까? 이 양식에 맞춰 내용을 입력해 주시면 회신 드리겠습니다.

로데슈바르즈에서 다음과 같은 방법으로 정보를 수신하겠습니다

마케팅 동의

이것이 의미하는 바는 무엇입니까?

Rohde & Schwarz GmbH & Co. KG 및 본 웹사이트에서 명기하는 Rohde & Schwarz 법인 혹은 지사에서
테스트 및 계측, 보안 통신, 모니터링 및 네트워크 테스트, 방송 및 미디어, 사이버 보안 분야의 제품, 솔루션과 관련된 마케팅 및 광고 목적(예: 특별 행사 및 할인 프로모션에 대한 정보)을 위해 선택한 채널(이메일 또는 우편)을 통해 연락하는 데 동의합니다.

이용자의 권리

이 동의 선언은 news@rohde-schwarz.com에 "Unsubscribe"라는 제목으로 이메일을 보내 언제든지 취소할 수 있습니다. 또한 전송되는 각 이메일에 향후 이메일 광고에 대한 구독 취소 링크가 포함되어 있습니다. 개인 데이터 사용 및 해지 절차에 대한 자세한 내용은 "개인정보 보호정책"에 명시되어 있습니다.

신청하신 내용이 제출되었습니다. 빠른 시일 내 회신 받으실 것입니다.
An error is occurred, please try it again later.
일반 정보 및 법정 정보

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.