Key Facts

  • Outstanding efficiency ensuring minimum operating costs
  • Multistandard platform for analog, digital and mobile TV

Brief Description

The R&S®NV8600 high-power transmitter family broadcasts TV signals in UHF bands IV/V. High power density, excellent transmission quality and superb reliability are the reasons behind the family's successful use in analog, digital and mobile TV networks all over the world.

Features

  • Future-ready and adaptable
  • Energy-efficient with small footprint

Specifications

Number of R&S®VH8600A1 amplifiers Output power (RMS) for COFDM standards
2 1.3 kW

Key Facts

  • Outstanding efficiency ensuring minimum operating costs
  • Multistandard platform for analog, digital and mobile TV
  • DVB-T2 capability
  • Simple switchover from analog to digital TV
  • Compact, efficient and flexible liquid-cooling system

Brief Description

The R&S®NV8600 high-power transmitter family broadcasts TV signals in UHF bands IV/V. High power density, excellent transmission quality and superb reliability are the reasons behind the family's successful use in analog, digital and mobile TV networks all over the world. Owing to its outstanding energy efficiency and small footprint, the transmitter family decisively contributes to the reduction of operating costs in modern transmitter networks.

Features & Benefits

  • Future-ready and adaptable
    • Multistandard platform for use worldwide
    • Modular design
    • Configurable for different AC supply voltages
  • Energy-efficient with small footprint
    • UHF broadcast transmitters with excellent efficiency
    • Constant efficiency even at reduced output powers
    • Compact design for low infrastructure costs
  • Always on the air
    • All components from a single source for highest quality standards
    • Reliable system design
    • Dependable and low-energy liquid cooling
    • Standby systems for all requirements

Specifications

Digital TV
Number of R&S®VH8600A1
amplifiers
2 3 4 5 6 8 10 12 16 20
Output power (RMS)
for COFDM standards 1) 2) 3)
1.3 kW 1.9 kW 2.6 kW 3.1 kW 3.7 kW 5.0 kW 6.1 kW 7.2 kW 9.7 kW 11.8 kW
RF output for COFDM standards EIA 1 5/8" EIA 3 1/8"
Output power (RMS)
for ATSC/ATSC Mobile DTV 1) 2) 4)
1.8 kW 2.7 kW 3.6 kW 4.4 kW 5.2 kW 7.0 kW 8.5 kW 10.1 kW 13.6 kW 16.5 kW
RF output for ATSC/ATSC Mobile DTV EIA 1 5/8" EIA 3 1/8" EIA 4  1/2"
Dimensions
(H × W × D)
2000 mm × 600 mm × 1100 mm
(78.7 in × 23.6 in × 43.3 in)
2000 mm × 1200 mm ×  1100  mm
(78.7 in × 47.2 in × 43.3 in)

1) Before bandpass filter.

2) With AC power supply of 3 × 400 V AC.

3) Average output power; at < 510 MHz, power reduced by approx. 10 %; at > 662 MHz, power increased by approx. 5 %.

4) Average output power; at < 510 MHz, power reduced by approx. 5 %; at > 662 MHz, power increased by approx. 6 %.

 

Specifications
Digital TV
TV standards   DVB-T, DVB-T2, DVB-H, ISDB-T, ISDB-TB, DTMB, MediaFLO, ATSC, ATSC Mobile DTV,
Inputs   4 × BNC, 75 Ω
  DVB-T2 2 × BNC, 75 Ω and 2 × RJ-45
General data
Frequency range UHF bands IV/V 470 MHz to 862 MHz
Power supply with three-phase amplifiers (standard) 3 × 400 V ± 15 % 1),
47 Hz to 63 Hz
  with single-phase amplifiers (optional, for R&S®NV8602 to R&S®NV8610) 3 × 208 V – 10 %/+ 15 % 1) or
240 V – 15 %/+ 10 % 2)
47 Hz to 63 Hz
Max. installation altitude   2000 m above sea level
(> 2000  m on request)
Operating temperature range   +1 °C to +45 °C
Relative humidity (max.)   95 %, non-condensing
Immunity 3) to fast transients and burst in line with IEC  61000-4-4 < 4 kV (AC supply),
< 1 kV (signal inputs)
  to surges in line with
IEC  61000-4-5
balanced < 2 kV (e.g. L1-L2)
unbalanced < 4 kV (e.g. L1-N)
Synchronization
Reference frequency   10 MHz, 0.1 V to 5 V (Vpp) or TTL, BNC
Reference pulse   1 Hz, TTL, BNC
Operation
Display, keypad and status LEDs   local operation and display
Ethernet interface, RJ-45   convenient operation, local or remote, via standard web browser
  optional network management interface via SNMP
Parallel remote-control interface optional floating contacts for messages and commands

1) To be connected to an AC supply network with Y, 3w + N + PE.
2) To be connected to an AC supply network with 120/240 V, 2w + N + PE.
3) With integrated AC supply overvoltage protection; more stringent requirements must be covered by additional on-site measures.

To comply with the applicable standards and limit values for the suppression of out-of-band emissions (and in the case of digital standards, also for maintaining the required shoulder distance), the transmitter may only be operated with suitable filters at the RF output.

Gracias.

La solicitud se ha enviado correctamente.

En breve nos pondremos en contacto con usted.

Su equipo de servicio Rohde & Schwarz

Solicitar presupuesto

Introduzca su consulta.
Introduzca su nombre.
Introduzca el nombre.
Introduzca una dirección de correo electrónico válida.
Introduzca el nombre de la empresa.
Introduzca el nombre de la ciudad.
Introduzca el código postal.
Introduzca el número de teléfono.

Introduzca el país.
Permiso de marketing

Deseo recibir información de Rohde & Schwarz por


¿Qué significa esto exactamente?

Estoy de acuerdo con que ROHDE & SCHWARZ GmbH & Co. KG y la entidad o subsidiaria ROHDE & SCHWARZ que figure en la Declaración de confidencialidad del sitio web se ponga en contacto conmigo a través del canal elegido (correo electrónico o correo postal) para fines de marketing y publicitarios (p. ej., información sobre ofertas especiales y promociones de descuentos) en relación con, pero sin limitarse a, productos y soluciones para prueba y medición, comunicaciones seguras, monitoreo y pruebas de redes, broadcast y media así como ciberseguridad.

Sus derechos

Esta declaración de consentimiento se puede retirar en cualquier momento enviando un correo electrónico a news@rohde-schwarz.com con el asunto «Cancelar mi suscripción». Además, en cada correo electrónico enviado se incluye un enlace para cancelar por correo electrónico la suscripción a futuros anuncios. En la Declaración de privacidad encontrará información adicional sobre el uso de los datos personales y el procedimiento de retirada.

Introduzca los caracteres que se muestran en la imagen
show captcha
Datos incorrectos.
Do not enter data in this field
Gracias.

La solicitud se ha enviado correctamente.

En breve nos pondremos en contacto con usted.

Su equipo de servicio Rohde & Schwarz

Solicitar información

Introduzca su consulta.
Introduzca su nombre.
Introduzca el nombre.
Introduzca una dirección de correo electrónico válida.
Introduzca el nombre de la empresa.
Introduzca el nombre de la ciudad.
Introduzca el código postal.

Introduzca el país.
Permiso de marketing

Deseo recibir información de Rohde & Schwarz por


¿Qué significa esto exactamente?

Estoy de acuerdo con que ROHDE & SCHWARZ GmbH & Co. KG y la entidad o subsidiaria ROHDE & SCHWARZ que figure en la Declaración de confidencialidad del sitio web se ponga en contacto conmigo a través del canal elegido (correo electrónico o correo postal) para fines de marketing y publicitarios (p. ej., información sobre ofertas especiales y promociones de descuentos) en relación con, pero sin limitarse a, productos y soluciones para prueba y medición, comunicaciones seguras, monitoreo y pruebas de redes, broadcast y media así como ciberseguridad.

Sus derechos

Esta declaración de consentimiento se puede retirar en cualquier momento enviando un correo electrónico a news@rohde-schwarz.com con el asunto «Cancelar mi suscripción». Además, en cada correo electrónico enviado se incluye un enlace para cancelar por correo electrónico la suscripción a futuros anuncios. En la Declaración de privacidad encontrará información adicional sobre el uso de los datos personales y el procedimiento de retirada.

Introduzca los caracteres que se muestran en la imagen
show captcha
Datos incorrectos.
Do not enter data in this field
International Website