R&S®NGP800 Power supply series

A performance power supply from R&S Essentials

R&S®NGP800 Power supply series
Abrir Lightbox
R&S®NGP800 Power supply series
Abrir Lightbox
R&S®NGP800 Power supply series
Abrir Lightbox
R&S®NGP800 Power supply series
Abrir Lightbox
R&S®NGP800 Power supply series
Abrir Lightbox
R&S®NGP800 Power supply series
Abrir Lightbox
R&S®NGP800 Power supply series
Abrir Lightbox
R&S®NGP800 Power supply series
Abrir Lightbox
R&S®NGP800 power supply series, front view R&S®NGP800 power supply series, front low R&S®NGP800 power supply series, 3D R&S®NGP800 power supply series, back view R&S®NGP800 power supply series, 3D R&S®NGP800 power supply series, front view R&S®NGP800 power supply series, front view R&S®NGP800 power supply series, front view

Key Facts

  • Max. output power: 800 W
  • Max. voltage per channel: 32 V or 64 V
  • Max. current per channel: 10 A or 20 A
  • Up to 250 V or 80 A in series or parallel operation
  • Intuitive, price-transparent online product configurator

Boost your efficiency with quadcore power

The R&S®NGP800 DC power supply series, comprising of five models with 400 W or 800 W, provides maximum power at a variety of operating points. The two or four 200 W outputs can each supply up to 64 V or up to 20 A. Electrically equivalent and galvanically isolated outputs can be wired in series or parallel for up to 250 V or 80 A. The R&S®NGP800 DC power supply series is ideal for a variety of T&M scenarios: automotive, R&D, manufacturing and general purpose use. 
Configure your R&S®NGP800 with our online configurator tool for: 
- full price transparency
- ease of configuration
- fast processing of your request and purchase from authorized distributor of your choice
Click "configure and quote" and start your configuration now.
 

Features & benefits

Touch display

High-resolution touch display for easy operation

The large high-resolution touch display makes operation easy. Quickly navigate through the menus to access all functions and settings. Enter values much faster with the virtual keyboard instead of a knob. The home screen gives you a clear overview of all your channels. Each channel can be selected for a more detailed view with a wide variety of additional information, such as statistics and icons indicating the status of set protection or special functions.

The home screen gives a clear overview of all channels
Abrir Lightbox

The home screen gives a clear overview of all channels

FlexPower

Get the maximum power at various operating points

Unlike with single range power supplies, you can generate variable voltage and current combinations within the overall power limit of 200 W per channel. This technology makes your power supply a lot more versatile, covering a wider range of applications.

V/I-curves for 32 V output and 64 V output
Abrir Lightbox

V/I-curves for 32 V output and 64 V output

Parallel & serial operation

Up to 250 V or 80 A

If your application requires more voltage or current, connect the outputs in series or parallel and get up to 250 V (R&S®NGP824) or 80 A ( R&S®NGP804) - for the flexibility you always wanted. Using the tracking function, voltage and current are adjusted on all selected channels simultaneously.

Parallel & serial operation
Abrir Lightbox

Parallel & serial operation

Built-in measurements

Integrated statistics

The built-in measurements reduce the need for an external multimeter and simplify the setup. The separate voltage and current meters on each output have a resolution of 1 mV and 0.5 mA over the full output range of 64 V and 20 A. Integrated statistics show the min, avg and max values for power, voltage and current as well as the energy count.

One-channel-view with details and integrated statistics
Abrir Lightbox

One-channel-view with details and integrated statistics

Data Logging

Key to long-term monitoring

Logging data is key to long-term monitoring, reviewing test setups and repeating test conditions when analyzing power behavior or optimizing power consumption. The R&S®NGP800 power supplies simultaneously log voltage and current measurements over time on all outputs. You can easily export the timestamped data as a .CSV file for reports and documentation.

Logging setup dialog
Abrir Lightbox

Logging setup dialog

Arbitrary function

QuickArb

Emulate the normal behavior of your power subsystem early in the design process and simulate power problems for DUT design verification. The QuickArb function lets you generate voltages that vary over time and current sequences of output changes with dwell times down to 1 ms. Load up to eight subgroup files into one sequence to create complex patterns.

Fast programming of sequences with the Arb Editor
Abrir Lightbox

Fast programming of sequences with the Arb Editor

Graphical View

Display of measured data

The Graphical View function allows fast and convenient analysis, especially of changing processes, such as charging and discharging or switching between different operating states of a DUT. Integrating all measurements in one box not only reduces the complexity of the test setup, but also ensures the integrity and correlation of all measurements by design.

The Graphical View function interface on an R&S®NGP800 power supply
Abrir Lightbox

The Graphical View function interface on an R&S®NGP800 power supply

Remote control via VNC client

Control your instrument from anywhere

Via VNC connection the R&S®NGP800 power supplies can be controlled and operated from any location. All functions that can be reached by manual operation can also be accessed via remote control by VNC. The connection between power supply and PC can be established via LAN in the same network.

Remote control of R&S®NGP800 power supply via VNC
Abrir Lightbox

Remote control of R&S®NGP800 power supply via VNC

Easy to use, price transparent configurator

We strive to give customers the right T&M instrument quickly, easily, and with full price transparency. The R&S®NGP800 and other instruments from the R&S Essentials portfolio can now be configured online, providing you with the following benefits:
- User-friendly and easy to navigate configurator
- Full cost transparency at every step of configuration
- Fast order processing through authorized distribution partners 
- Next-day delivery from selected partners

Abrir Lightbox

Available models

Available models
Modelos
Number of output channels
Max. output power
Output voltage per channel
Output current per channel
A partir de

R&S®NGP802

Order Number 5601.4007.05

Number of output channels
2
Max. output power
400 W
Output voltage per channel
0 V to 32 V
Output current per channel
0 A to 20 A
A partir de
Consultar precio

R&S®NGP804

Order Number 5601.4007.02

Number of output channels
4
Max. output power
800 W
Output voltage per channel
0 V to 32 V
Output current per channel
0 A to 20 A
A partir de
Consultar precio

R&S®NGP814

Order Number 5601.4007.04

Number of output channels
4
Max. output power
800 W
Output voltage per channel
Ch 1, Ch 2: 0 V to 32 V
Ch 3, Ch 4: 0 V to 64 V
Output current per channel
Ch 1, Ch 2: 0 A to 20 A
Ch 3, Ch 4: 0 A to 10 A
A partir de
Consultar precio

R&S®NGP822

Order Number 5601.4007.06

Number of output channels
2
Max. output power
400 W
Output voltage per channel
0 V to 64 V
Output current per channel
0 A to 10 A
A partir de
Consultar precio

R&S®NGP824

Order Number 5601.4007.03

Number of output channels
4
Max. output power
800 W
Output voltage per channel
0 V to 64 V
Output current per channel
0 A to 10 A
A partir de
Consultar precio
Specifications
Electrical specifications
Number of output channels 2 or 4
Total output power max. 400 W/800 W
Maximum output power per channel 200 W
Output voltage per channel 0 V to 32 V (32 V channels)
0 V to 64 V (64 V channels)
Maximum output current per channel 20 A (32 V channels)
10 A (64 V channels)
Voltage ripple and noise (20 Hz to 20 MHz) < 3 mV (RMS)
< 30 mV (Vpp) (meas.)
Current ripple and noise (20 Hz to 20 MHz) < 3.5 mA (RMS) (meas.)
Load recovery time (10 % to 90 % load change within a band of ± 20 mV of set voltage) < 400 μs (meas.)
Programming resolution voltage 1 mV
Programming resolution current 0.5 mA
Output measurements
Readback resolution voltage 1 mV
Readback resolution current 0.5 mA
Readback accuracy voltage ±(% of output + offset) < 0.05 % + 5 mV (32 V channels)
< 0.05 % + 10 mV (64 V channels)
Readback accuracy current ±(% of output + offset) < 0.1 % + 20 mA (32 V channels)
< 0.1 % + 10 mA (64 V channels)
Special functions
Measurement functions voltage, current, power, energy
Protection functions OVP, OCP, OPP, OTP
FuseLink function
Fuse delay at output-on
Sense function
Sink mode
Output sequencing
Trigger input/output
Arbitrary function ● (QuickArb)
Analog/modulation interface
Data logging ● (standard mode)
Display and interfaces
Display TFT 5" 800 pixel × 480 pixel WVGA touch
Rear panel connections 8-pin connector block per 2 channels
Remote control interfaces: standard USB, LAN
Remote control interfaces: optional IEEE-488 (GPIB)
General data
Dimensions (W × H × D) 362 mm × 100 mm × 451 mm
Weight 7.5 kg/8.0 kg
Rack installation R&S®ZZA-GE23 option

Available options

General
Product
Descripción
R&S®NG-B105

Order Number 5601.6000.02

Descripción

IEEE-488 (GPIB) interface

General analysis
Product
Descripción
R&S®NGP-K103

Order Number 5601.6300.03

Descripción

Digital trigger I/O

R&S®NGP-K107

Order Number 5601.6200.03

Descripción

Analog input

General accessories
Product
Descripción
R&S®ZZA-GE23

Order Number 5601.4059.02

Descripción

19" rack adapter, 2 HU

Related videos

Webpage, VNC & FTP on R&S®DC Power Supplies

Learn how easy it is to control and operate our instrument from any location via ethernet-based remote services

Aumente su eficiencia con la potencia de cuatro canales

Con cuatro salidas independientes, cada una de hasta 64 V o 20 A, las nuevas fuentes de alimentación R&S®NGP800 aumentarán la eficiencia en cualquier laboratorio.

feb 13, 2020

DC Supplies promotion

DC Supplies and Component analysis promotion

Maximize your bench performance and benefit from more than 19% of of fully equipped DC power supplies.

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Permiso de marketing

Se ha enviado su solicitud. Nos pondremos en contacto con usted en breve.
An error is occurred, please try it again later.
Información general y jurídica

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Términos y condiciones:

La convocatoria es válida del 5 de Abril al 20 de junio de 2021. Participan transmisores de radio FM y TV de cualquier marca que se encuentren aún en operación. Se tomarán válidos para participar los datos registrados solo durante ese periodo de tiempo, solo se puede llenar el formulario 1 vez por persona. El acceso a ingresar datos en el formulario se restringirá el día 21 de Junio a las 00:00hrs. El 30 de Junio de 2021 anunciaremos a un ganador de cada categoría en este mismo web, por correo electrónico y a través de nuestras redes sociales. Más informacion. Anamaria@rohde-schwarz.com

Términos y condiciones del sorteo de premios con motivo del 10° aniversario de los osciloscopios de Rohde & Schwarz

1. El sorteo «10 años de osciloscopios de Rohde & Schwarz» (en adelante el «sorteo») está organizado por Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Múnich, Alemania, tel. +49 89 41 29 0 (en adelante «R&S»).

2. Todos los participantes pueden inscribirse en el sorteo entre el 1 de enero de 2020 y el 31 de diciembre de 2020 indicando su nombre, el nombre de su compañía y el correo electrónico empresarial.

3. La participación es gratuita y no está vinculada a la compra de bienes o servicios.

4. El sorteo está destinado únicamente a personas jurídicas, y solamente éstas tienen facultad para recibir los premios. No está permitida la participación de una persona individual por nombre y cuenta propia, sino que deberá hacerlo como representante de una persona jurídica llenando el formulario de participación en nombre y por cuenta de dicha persona jurídica.

5. Los participantes pueden ganar uno de los 10 R&S®RTB2000 sorteados entre el 1 de enero de 2020 y el 31 de diciembre de 2020:

Premio: 1 osciloscopio digital R&S®RTB2000

6. El sorteo tendrá lugar en la sede de R&S, Muehldorstrasse 15, 81671 Múnich (Alemania). Los ganadores de los premios serán informados por correo electrónico en un plazo de cinco (5) días laborables.

7. El representante autorizado de la persona jurídica deberá notificar a R&S que acepta el premio. En caso de no aceptación o de no obtenerse respuesta en un plazo de dos (2) semanas, se sorteará un nuevo ganador. Si no puede determinarse un ganador en un espacio de cuatro (4) semanas, el sorteo se dará por finalizado y el premio se dará por perdido.

8. Los empleados de R&S, sus familiares, así como cualquier persona que esté implicada en el proceso del sorteo y sus familiares quedan excluidos de llenar el formulario de participación.

9. No está permitido abonar el equivalente en metálico ni intercambiar los premios. Los premios son intransferibles. Todos los impuestos, gravámenes, tasas de aduana, cuotas y otros pagos exigidos en el país del participante correrán por cuenta del participante.

10. Los datos personales se procesarán exclusivamente para los fines de este sorteo de premios y se eliminarán cuatro (4) semanas después de finalizar el mismo, salvo otro acuerdo.

11. R&S se reserva el derecho de descalificar del concurso a cualquier participante que no cumpla los presentes términos y condiciones. En estos casos, los premios también podrán retirarse con efecto retroactivo. En caso de retirarse un premio con efecto retroactivo como consecuencia del incumplimiento de los presentes términos y condiciones, el respectivo participante deberá devolverlo, corriendo con los gastos correspondientes, a la dirección de R&S indicada en el punto 1, y se sorteará un nuevo ganador.

12. Los participantes no tienen derecho a reclamar los premios de este sorteo, ni está previsto ningún recurso legal a este respecto.

13. El sorteo, y cualquier relación contractual que se derive del mismo entre R&S y el respectivo participante, se regirán e interpretarán según la legislación de Alemania, excluyendo todo recurso por conflictos de leyes. Los tribunales de Múnich, Alemania, tendrán la competencia exclusiva en caso de cualquier litigio relacionado directa o indirectamente con la participación en este concurso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.