This application note describes how to measure balanced reflection mixed mode S-Parameters with a 2-port Network Analyzer like R&S® ZVL. The application note directly transfers S-Parameter Trace Data from R&S® Network Analyzers to Microsoft™ Excel™ using a direct connection like GPIB or LAN and does the mode conversion to Mixed Mode inside Excel™ with a VBA Macro.
14-Feb-2008 | AN-No. RSI05
This document describes how a Windows®-based R&S® T&M instrument is remotely operated by an Apple iPad as if working on it locally. Step-by-step procedures are provided for setting up and configuring the T&M instrument and the iPad. On the iPad, a special App implements the Windows® 'Remote Desktop' functionality. T&M instrument and iPad are connected via WLAN (also denoted as Wi-Fi network).
28-Mar-2013 | AN-No. 1MA216
The combination of an SMIQ Signal Generator and an FSE / FSIQ Analyzer enables the most important transmitter and receiver tests on ICO user terminals in quality management and development. This application note presents a series of quick tests in unsynchronized, non-signalling mode. To facilitate integration of SMIQ and FSE / FSIQ into existing test systems, complex instrument settings are supplied as sets of IEC/IEEE-bus commands. Sample files with burst data for uplink and downlink signals allow the configuration, execution and optimization of the tests described, even without a DUT.
08-May-2000 | AN-No. 1MA23
Unattended observation of spectrum occupancy for finding spurious emissions or seldom-occuring interferers is a common task for spectrum analyzers. Sometimes spectrum data has to be monitored over quite a long period of time. TraceRecorder, a small, free-of-charge software tool for storing measurement data from Rohde & Schwarz spectrum analyzers helps you to perform this measurement task. Running on a PC, it connects to the spectrum analyzer via a LAN interface. For stand alone operation, it is possible to run it directly on a spectrum analyzer, eliminating the need for an additonal computer during data acquisition.
08-Dec-2010 | AN-No. 1MA105
Interferences on audio transmissions, which happens only from time to time, are very difficult to be measured. This application note describes a method, used by the audio analyzers UPL and UPD, to monitor test tones without any interruption and detecting even the shortest clicks.
04-Jun-1998 | AN-No. 1GA31
The R&S®RTB2000 digital oscilloscope lets you share your scope’s display with any computer/projector via LAN or Internet. The oscilloscope comes with an RJ-45 Ethernet jack and a built-in web server (as standard). The screen is displayed via a direct connection to a PC, via LAN or over the Internet.
21-Mar-2017
Spectrum and network analyzers equipped with network interface cards can be integrated in Local Area Networks (LAN). This Application Note describes how to remote control these instruments over a LAN and use VXIpnp instrument drivers over a LAN.
25-Jun-2003 | AN-No. 1EF47
This application note provides information how to perform spectral emissionmeasurements on pulsed signals with spectrum analyzers using RBW filters with verywide bandwidth, and explains the capabilities and the limiting factors of the Rohde &Schwarz FSW signal and spectrum analyzer to perform this measurement.
06-Jun-2019 | AN-No. 1EF106
This application note addresses the diverse possibilities of interoperability between Rohde & Schwarz power sensors and Rohde & Schwarz signal generators. All current and many legacy Rohde & Schwarz signal generators offer the capability of directly connecting power sensors. This enables power measurements without the need of a base unit or separate PC to display the readings. Furthermore, sensors can be used for special tasks like filling a user correction table or continuously controlling levels at crucial points in the measurement configuration.
31-Aug-2023 | AN-No. 1GP141
DIRECTV®, a digital TV broadcast system, makes use of transport packets with a length of 130 bytes rather than the more common 188 bytes used in MPEG TS streams. The inputs on the R&S® SFU do not accept transport streams in the DIRECTV® format. This Application Note introduces R&S® DIRECTV tool and explains how it can be used to convert existing 130-byte-based DIRECTV® transport stream content to 188-byte-based ISO 13818-1 streams that are compatible with the R&S® SFU SPI input or the internal R&S® SFU TRP player. This tool is intended for Rohde & Schwarz customers who are licensed to operate an R&S® SFU-K9 DIRECTV coder or R&S® SFU-K108 AMC coder.
05-Oct-2007 | AN-No. 7BM69
The R&S®BTC broadcast test center generates DVB-C2 signals for receiver tests with a variety of simulated interference types. The selection tests stipulated by the DVB Project require a cable TV network with full channel load. Combining the R&S®BTC broadcast test center and the R&S®CLG cable load generator makes it quick and easy to create a flexible cable TV network with full channel load and to simulate all types of realistic interference, permitting tests in accordance with DVB.
30-Jul-2013 | AN-No. 7BM88
Autonomous and semi-autonomous vehicles rely on a complex hardware and software architecture to gather and exploit information from numerous radar sensors. To generate reliable data, the sensors require an unobstructed view of the surroundings. The bumpers or radomes mounted in front of the sensors must not impair radar functionality. This requires extensive testing of the deployed plastic parts and their underlying polymer structure. The R&S®QAR50 is the ideal tool to characterize the material properties of polymers and their influence on the quality of the radar signal at an early design stage and in quality control of material development.
24-Jun-2022
This application note describes the use of the R&S FSUP26/50 with frequency dividers to extend cross correlation range to higher frequencies.
10-Apr-2007 | AN-No. 1EF56
This operation guide describes how to measure HSUPA test cases according to 3GPP TS 34.121 V8.0 with R&S®CMU200. Setting files according to the test requirements are attached.
08-Oct-2009 | AN-No. RCS0712-0053
IQWizard is a tool for loading IQ signal files in various formats and measuring IQ signals with a FSx spectrum analyzer or ESx Receiver. The obtained IQ data in memory can be stored in various formats or be transmitted to an R&S® vector signal generator with WinIQSIM™ or WinIQSIM2™.
26-Apr-2013 | AN-No. 1MA028
Next generation technologies in radar and satellite communication with high data rates call for innovative testing solutions to develop and manufacture RF components like voltage controlled oscillators (VCO). The R&S®FSPN phase noise analyzer increases efficiency and reproducibility of VCO characterization and phase noise measurements from lab to production.Voltage controlled oscillators are oscillators whose output frequency is controlled by means of an external tuning voltage, and they are used in a wide variety of electronic and RF applications like function generators, phase-locked loops including frequency synthesizers used in communication equipment. Different VCO design approaches yield different parameters and performance, and therefore it is important to measure or characterize VCOs under different conditions. This application note provides a short technical introduction to voltage controlled oscillators and explains the most common and the most important measurements made during the VCO characterization process.
17-May-2023 | AN-No. 1SL386
Rare faults and intermittent signals are difficult to capture. The R&S®RTO Oscilloscope supports the acquisition and the detailed signal analysis of these signals by using the history mode. The history mode allows the user to look back to previous acquisitions and apply the wide set of analysis functions of the RTO. Furthermore it stores the accurate recoding time of the waveforms for subsequent analysis.
03-Jun-2013 | AN-No. 1TD02
The DVB-H standard is a specification for bringing television broadcast services to handheld receivers. In order to save battery power, data for a specific service is transmitted in short bursts. This type of transmission utilizes special techniques within the transport stream. The R&S DVM offers a wide range of functions to analyze the characteristics of the DVB-H transport stream. This document describes the characteristics of the DVB-H transport stream and shows how the R&S DVM can be used for efficient analysis in research and development, production, and broadcasting.
04-Jul-2006 | AN-No. 7BM59
Using R&S®ELEKTRA Migration Tool
The R&S®ELEKTRA EMC test software is the successor of the R&S®EMC32 EMC measurement software. Like the R&S®EMC32 EMC measurement software, the R&S®ELEKTRA offers a solution that controls complete EMC systems and automates measurements on equipment under test (EUT) that is being tested for emissions (EMI) and immunity (EMS) compliance. It has more features and test types compared to R&S®EMC32.As both software platforms use different file formats, R&S®EMC32 users who upgrade their existing software to the R&S®ELEKTRA platform need to perform a file conversion before migrating their data to the R&S®ELEKTRA platform. This is done by using the R&S®ELEKTRA Migration Tool, which is installed automatically with each R&S®ELEKTRA installation.This Application Note describes how to use the R&S®ELEKTRA Migration Tool (version 4.4 onwards) for converting the backup data into the XML format that can be interpreted by the R&S®ELEKTRA software. It also provides recommended conversion steps (Chapter 5) and troubleshooting tips (Chapter 6). For instructions on migrating the data using R&S®ELEKTRA Migration Tool below version 4.4, refer to the R&S®ELEKTRA user manual. For better user experience, we recommend using the latest software version for migration.This Application Note does not describe the steps to backup data using the R&S®EMC32 or R&S®ES-SCAN software. For procedures on how to do so, refer to their respective manuals.
04-May-2023 | AN-No. 1SL396
This application note provides information about measurements on DVB-S2 transmitters, including Amplitude Phase Shift Keying (APSK) signals. Specifically, this note will discuss how to import APSK mapping files in order to make modulation quality measurements.
09-Feb-2010 | AN-No. 1MA172
This application note explains how to convert different Rohde & Schwarz I/Q file formats among each other using the supplied software tool.
23-Sep-2015 | AN-No. 1EF85
The following application note describes the function and operation of user menus for FSE Spectrum Analyzers including option Vector Signal Analysis (FSE-B7). For measurements according to the GSM standard user menus are provided, which perform settings on FSE for Base Station testing required in the standard. The menu and the accompanying setups are stored on a floppy disk. For operation of the menus firmware version 1.40 or higher is required. Option Vector Signal Analysis FSE-B7 has to be installed for the use of the application menu.
16-Jan-2002 | AN-No. 1EF23
The Electromagnetic Disturbance (EMD) emitted by Proximity-Integrated-Circuit-Cards (PICC) is a unwanted form of load modulation. This Application Note describes a method for measuring EMD during data transmission using vector signal analysis
19-Oct-2007 | AN-No. 1MA120
This application note explains the measurements on 3GPP Base Station Transmitter signals according to TS 25.141, using the Signal Analyzer FSIQ with the Code Domain Power application firmware FSIQ-K72.
17-Aug-2001 | AN-No. 1EF44
This application note describes how to measure the control loop stability of switch-mode power supplies to get the best performance and confidence of the design. It will explain the main measurement concept and will guide the user during the measurements and mention the main topics in a practical manner. Wherever possible, a hint is given where the user should pay attention to it to avoid weak measurements. The Rohde and Schwarz buck converter reference board was designed in collaboration with Texas Instruments and is used to illustrate the closed loop measurement in a practical manner.
01-Jul-2019 | AN-No. GFM321
The R&S®ELEKTRA EMC test software is a solution that controls complete EMC systems and automates measurements on equipment under test that is being tested for emissions and immunity compliance. It can be used to remotely control R&S®AdVISE, which is a visual inspection software to monitor up to 32 different Regions of Interest in one video for visible and audible changeThis Application Note describes how to set up R&S®ELEKTRA and R&S®AdVISE for remote testing.
23-Jul-2020 | AN-No. 1S005
This application note explains how to create screenshots of Rohde & Schwarz instruments using instrument drivers. The presented examples are written in C (LabWindows/CVI), C# programming language and LabVIEW. The examples are available at the instrument driver download site.
11-Dec-2009 | AN-No. 1MA160
All types of information transmission, including the 'one-way' transmission used in broadcasting, involve feeding a radio frequency (RF) signal to an antenna. This is the essence of the most basic type of transmitter used to emit electromagnetic waves. In the real world, however, a transmitter used for broadcast applications, for example, is much more complex in terms of its functions and design. The different transmitter components must be carefully coordinated. There are many quality parameters that are critical in ensuring that a proper output signal is delivered. Rohde & Schwarz designed the R&S® ETL TV analyzer especially for broadcasting applications. The analyzer allows the measurement of the quality parameters that are relevant in analog and digital broadcasting. This Application Note describes the typical quality measurements performed during compliance testing of TV transmitters. The approach discussed here is based on the example of Rohde & Schwarz terrestrial transmitters for analog TV and DVB-T/H.
19-Sep-2007 | AN-No. 7BM67
Noise sources used for noise figure and gain measurements are typically controlled by the spectrum analyzer or noise figure meter instruments and are calibrated with their ENR value (Excess noise ratio). While this external control and the use of ENR values is common in noise figure test, it may be difficult in system applications where the noise source control is not available, and the use of ENR values is replaced with the values for the noise output power of the noise source. The calculation of the output power for the noise source requires to know the P_hot value (hot power) which is not a common specification for noise sources used in test and measurement applications.This application note describes a technique to perform a calibrated noise power measurement (P_hot) with spectrum analyzers and noise sources. The next sections will give further details.
31-May-2022 | AN-No. 1EF113
The vector signal generators and GNSS simulators R&S®SMW200A and R&S®SMBV100B are remote-controllable in realtime and can therefore be implemented into a dynamic HIL environment. The HIL simulator can dictate position coordinates, kinetic parameters, and vehicle attitude information based upon which the R&S® GNSS simulator updates the simulated receiver movement in realtime. This application note presents background information and details about operating a R&S® GNSS simulator in HIL applications.