Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
735 Results
Applications requiring higher voltages or currents, or a stack of voltage sources with taps in-between, demand the combination of several DC power supply channels in series or in parallel.All channels of DC power supplies R&S®NGL200 and R&S®NGM200 are isolated against the grounding equipment conductor and against the digital ground of the instrument. Therefore, channels can be connected in parallel for increasing the current capability, or in series for achieving higher voltages or dual-voltage supplies.When a large number of power supply channels is used, it is desirable to have a tool for configuring all instruments and channels from one user interface, and for keeping an overview over the states and measurement values from all channels.The application program of this application note provides such a tool. The document contains background information and user manual for the software.
27-Aug-2020 | AN-No. 1GP127
Power converter and inverter designs for higher power levels are usually based on hard switching half bridge configurations. In such setups, users must pay particular attention to proper switching operations to prevent shoot-through events. Setting up complex real-time trigger conditions using the R&S®RTE and R&S®RTO oscilloscopes increases the test coverage and robustness of converter and inverter systems.
10-Aug-2020
This application note describes how to detect even small fails in dynamic turn indicators with R&S®AdVISE.
30-Jul-2020 | AN-No. 1S006
Vector Network Analyzers of t ZNA and ZNB family are able to measure magnitude and phase of complex S-parameters of a device under test (DUT) in the frequency domain. By means of the inverse Fourier transform the measurement results can be transformed to the time domain. Thus, the impulse or step response of the DUT is obtained, which gives an especially clear form of representation of its characteristics. For instance, faults in cables can thus be directly localized. Moreover, special time domain filters, so-called gates, are used to suppress unwanted signal components such as multireflections. The measured data "gated" in the time domain are then transformed back to the frequency domain and an Sparameter representation without the unwanted signal components is obtained as a function of frequency. As usual, other complex or scalar parameters such as impedance or attenuation can then be calculated and displayed.
30-Jul-2020 | AN-No. 1EP83
This application note shows how to configure the R&S®AdVISE visual inspection software to automate the immunity testing in line with EN 55020 and CISPR 35 on TV sets and monitors.
30-Jul-2020 | AN-No. 1S007
The R&S®ELEKTRA EMC test software is a solution that controls complete EMC systems and automates measurements on equipment under test that is being tested for emissions and immunity compliance. It can be used to remotely control R&S®AdVISE, which is a visual inspection software to monitor up to 32 different Regions of Interest in one video for visible and audible changeThis Application Note describes how to set up R&S®ELEKTRA and R&S®AdVISE for remote testing.
23-Jul-2020 | AN-No. 1S005
The R&S®SMW-K546 software option aids the optimum design of multiple path amplifiers, including Doherty Amplifiers.This application note provides guidance on the use of the software option, both for direct control and programming via the touchscreen, and for remote control using SCPI.The software and associated techniques may similarly be used to develop other quasi-linear, multi-path amplifiers; including Balanced, Anti-Phase (so-called Push-Pull), Distributed, Spatially Combined, Load Modulated Balanced and many more.
13-Jul-2020 | AN-No. GFM345
radiated conformance testing according to TS 38.141-2, Rel. 16
3GPP defines the Radio Frequency (RF) conformance test methods and requirements for 5G NR Base Stations (BS) in the technical specifications TS 38.141. This application note describes all mandatory RF receiver tests (TS 38.141-2, chapter 7), according to Release 16.Furthermore, this document provides a brief introduction about the different R&S OTA antenna test solutions and how they are applicable for base station conformance testing. Rohde & Schwarz offers suitable solutions for any test case that is mentioned in this application note.
30-Jun-2020 | AN-No. GFM325
5G New Radio (NR) FR1 MIMO or beamforming downlink signal analysis especially the phase measurement of each MIMO layer and the determination of the phase difference between the MIMO layers are essential for the 5G base station product design.In this application note, it describes two test solutions from R&S® to cope with the 5G FR1 downlink MIMO signal analysis challenges either using R&S®RTP/RTO oscilloscope or R&S®NRQ6 frequency selective power sensor as RF frontend to capture the signal and together with R&S®VSE as post-processing tool for the IQ analysis.The aim of this application note is to walk the user through the necessary steps on both test solutions to enable the 5G FR1 downlink MIMO signal analysis.It is assumed that the reader has certain pre-knowledge of 5G NR physical layer. In case a refreshment is needed, please refer to the for further reading.
26-Jun-2020 | AN-No. GFM343
Measurements of very high noise figure components are performed for a number of reasons. For instance, in a wide range of applications, devices under test (DUT) are characterized within a complex test setup that includes high losses before or after the low noise DUT. In case of high frequencies, the switch matrix with complex signal routing and cables might have a very high loss. In other cases, the device might be embedded in a test setup where direct access is physically impossible, on-wafer probing is one example for this case. Using conventional measurement equipment, the noise figure measurement of such a device is very unstable if not impossible at all.
24-Jun-2020 | AN-No. 1EF110
This application note describes how to use the generic interface in R&S®AdVISE for remote operation.
19-Jun-2020 | AN-No. 1S002
All channels of DC power supplies R&S®NGL200 and R&S®NGM200 are isolated against the grounding equipment conductor and against the digital ground of the instrument. Therefore, channels can be connected in parallel for increasing the current capability, or in series for achieving higher voltages or dual-voltage supplies. In the case of parallel and serial connections it is usually desired to switch all channels simultaneously on and off for protecting the supplied circuitry and for avoiding overcurrent on other power supply channels.This application note describes how to connect and configure DC power supplies R&S®NGL200 and R&S®NGM200 for synchronized on and off switching of all channels across multiple power supplies.
15-Jun-2020 | AN-No. 1GP126
This application note describes different measurement techniques and methods for an automotive lighting module based on a hybrid controller design. Of course, a lighting module in such an environment has to fulfil requirements according to the automotive standard, which is typically a relatively high-level standard compare to the industry standard. The oscilloscope is a perfect tool for this application to verify the set of requirements because time domain signals (analog and digital) are present in the whole design. Furthermore, measurements in the frequency domain have to be performed, which a modern oscilloscope can fulfil. In addition to the oscilloscope, a programmable power supply supports the measurement in several measurements. The set of requirements are the main reason why a hybrid controller from Microchip is a great choice for this design because it provides tremendous analogue and digital capabilities. The hybrid controller provides beside the analogue functions like an operational amplifier digital functions like analog-to-digital converter and interface functions like UART, CAN or LIN to interact with other systems. The programmable software part is hosted in the digital part. The digital part of the controller implements the communication interface and provides status information to the outer system controller. The light source itself has to avoid any flicker and shall be capable to dim to different lighting levels. Wide input voltage variations and efficiency have to be taken into account during the design of a converter dedicated for automotive applications. Nevertheless, the measurement considerations presented with the design are valid and applicable in other professional lighting industries as well.Thanks to Mr. Andreas Reiter and Mr. Milan Marjanovic from Microchip who provided us with hardware and software and their great expertise to create this application note.
08-Jun-2020 | AN-No. GFM339
Joint solutions of R&S® and COMPRION®
The GSMA specified a global standard for remote provisioning and management of the embedded Universal Integrated Circuit Card (eUICC) in the machine-to-machine (M2M) environment as well as the consumer devices via Over the Air (OTA) methodology.This application note describes GSMA compliant remote eUICC provisioning test solution based on R&S® CMW500/CMW290/CMX500 and COMPRION® eUICC Profile Manager software tool. Moreover, an eUICC provisioning method for GSMA Security Accreditation Scheme (SAS) compliant consumer devices by adopting COMPRION® eSIM Test Profile Service is introduced which is essential for RF, protocol testing on R&S®CMW500/CMW290/CMX500 for eSIM capable consumer devices.
03-Jun-2020 | AN-No. GFM342
Since June 2017 almost all radio transmitters and receivers sold or put into operation in the European Union have to be tested for immunity against interferers in adjacent frequency bands. ETSI standard EN 303 345 defines the tests to be performed on broadcast sound receivers, and the requirements to be passed.This application note describes the test procedures and provides script files and interferer signals for the Broadcast Test Center R&S®BTC.
29-May-2020 | AN-No. 1GP117
R&S®VISA is a standardized software library that allows fast communications over diverse interfaces with a wide variety of T&M instruments that are detected on the network from PC applications. R&S®VISA also includes a trace tool that simultaneously monitors communications between multiple applications and T&M instruments, and permits targeted analysis with the aid of efficient filters.
26-May-2020 | AN-No. 1DC02
The R&S® IQ File Cutter can load IQ data from supported IQ file formats and export part of the signal to another file. This is helpful when dealing with long measurement recordings, of which only parts are of interest and should be extracted for further analysis.
11-May-2020 | AN-No. GFM338
Thanks to their multichannel capability, oscilloscopes are ideal for multichannel applications such as the analysis of MIMO signals (e.g. 5G NR, WLAN), multi-antenna radar signals and differential high-speed digital signals (e.g. USB 3.x). These applications require the oscilloscope channels to be tightly aligned. This means the channel-to-channel residual skew has to be measured accurately so that it can be compensated. The channel-to-channel phase mismatch is reduced to a minimum, which plays a crucial role in achieving reliable measurement results.
06-May-2020
The vector signal generators and GNSS simulators R&S®SMW200A and R&S®SMBV100B are remote-controllable in realtime and can therefore be implemented into a dynamic HIL environment. The HIL simulator can dictate position coordinates, kinetic parameters, and vehicle attitude information based upon which the R&S® GNSS simulator updates the simulated receiver movement in realtime. This application note presents background information and details about operating a R&S® GNSS simulator in HIL applications.
14-Apr-2020 | AN-No. 1GP102
Signal Generation and Analysis
This Application Note supplements the video series, describing signal generation and signal analysis for Dynamic Spectrum Sharing (DSS) for LTE and 5G NR. The video series is located below this paragraph.In this illustration, a four frame (40 subframes) long LTE sequence will be created, and exemplary MBSFN slots inserted, carrying 5G payloads. That signal sequence will be compiled and played by the SMW signal generator. The FSW signal analyzer LTE and 5G NR personalities are then used to analyze and verify the content of each subframe/slot.Three methods are presented, (1) Manual Entry using the GUI, (2) SCPI command sequence/remote control and (3) configuration file. The latter variants require the download of various files, available at the bottom.The configuration file approach offers the fastest time to initially setup. The SCPI command sequences provides some insight of the functionality and settings at each step, and the supplied MATLAB® script (only core license required) provides a prototype to illustrate the programming of successive slots or subframes. The Manual Entry approach, using the instrument's front panel GUI, provides a step-by-step set-up instruction, which can itself be augmented with SCPI recording, for easy modification and programming.MATLAB® is a registered trademark of The Mathworks, Inc.
30-Mar-2020 | AN-No. GFM337
This application note proposes a digital level shifter for connecting the I2S interfaces R&S®UPP-B2 and R&S®UPV-B41 to devices under test with a logic voltage different from 3.3 V.
27-Mar-2020 | AN-No. 1GA71
Vector Network Analyzers (VNA) are gaining popularity in the Signal Integrity community as time domain measurement and analysis tools. VNAs with 8 ports or more can provide significant decreases in test time by migrating from a 4-port measurement system to an 8-port measurement system. For tight tolerance DUTs that are barely within the test limit lines, small increases in accuracy can be realized by testing all of the test parameters at once, because the entire test setup is at the same temperature. This application note discusses the thermal advantages of testing an 8-port DUT with the R&S ZNBT VNA. The use of the ZNBT to assess and debug two differential pairs in a 20-inch backplane is presented.
18-Mar-2020 | AN-No. 1EZ83_0E
Well-matched RF ports are a crucial aspect to any RF system. Matched ports, for example, protect amplifier output ports from reflected power overload. This undesired reflected power could destroy the whole amplifier. Matched ports also maximize power transmission, effectively extending the battery life of wireless products such as those made for the internet of things (IoT).
05-Mar-2020
Gated spectrum method with the R&S®PR200
03-Feb-2020
radiated conformance testing according to TS 38.141-2, Rel. 16
3GPP defines the Radio Frequency (RF) conformance test methods and requirements for 5G NR Base Stations (BS) in the technical specifications TS 38.141. This application note describes all mandatory radiated RF transmitter tests (TS 38.141-2, chapter 6), according to Release 16.Furthermore, this document provides a brief introduction about the different R&S OTA antenna test solutions and how they are applicable for base station conformance testing. Rohde & Schwarz offers solutions for any test case that is mentioned in this application note.
20-Dec-2019 | AN-No. GFM324
The R&S®SMA100B signal generator offers a remote emulation feature that makes it possible to control the instrument by commands other than the built-in native SCPI commands. This feature allows the user to replace signal generators, e.g. from other manufacturers, with the R&S®SMA100B without having to change the remote control code.This application note describes how to use the remote emulation feature in general. Furthermore, it describes in detail the remote emulation for each supported instrument, limitations of the individual emulations and the remaining differences between the emulated and the original commands.
11-Dec-2019 | AN-No. 1GP120
This application note explains step by step all necessary settings for transmitting parameters of the disturbance signal from an EMS test to a dAV Camera System via serial port or LAN interface. The dAV Camera System overlays these parameters onto the camera signal.
10-Dec-2019
This application note is step by step guide on 5G New Radio (5G NR) signal generation and analysis capabilities using the R&S®SMW200A Vector Signal Generator equipped with software option SMW-K144 (5G NR option), in combination with the R&S®FSW Signal and Spectrum Analyzer and the software options FSW-K144 & FSW-K145 (5G NR Downlink & Uplink Signal Analysis). The R&S®VSE Vector signal explorer has also been used for analysis purpose in parallel to the FSW-K144 & FSW-K145 software options.It is assumed that the reader already has a deep understanding of the 5G New Radio standard as well as the testing aspects. If not, then please refer to the 5G eBook more a detailed overview on the fundamentals, procedures, testing aspects of the 5G NR technology.
22-Nov-2019 | AN-No. GFM322
This application program supports the logging and fast logging functionality of the power supplies R&S® NGM200, NGU201 and NGU401. Standard logging is also supported with power supply R&S® NGL200 and NGP800. Power supplies R&S® NGA100 and NGE100 are supported in the data collection mode. Charting functionality is available for logged voltage, current and power values.
14-Nov-2019 | AN-No. 1GP122