202 Results
12-Nov-2020
R&S RTP oscilloscope from Rohde & Schwarz wins prestigious LEAP AwardThe R&S RTP high-performance oscilloscope was granted this year’s LEAP Award (Leadership in Engineering Achievement Program) in silver in the test and measurement category. The award is given annually to most innovative and forward-thinking products serving the design engineering space, and was selected by 14 judges from various engineering and ICT institutions.
A sinus signal with i.e. 10 V peak-peak, frequency 1 MHz is applied. If I choose a vertical scale which is too small the peaks of the waveform are not displayed as they are out of range. Now I activate the digital filter in the “Vertical” menu à “Channel”. The frequency of the filter is also set to 1 MHz. Now even at very small vertical scales (i.e. 50 mV/div) the waveform is displayed completely, see screenshot. But the amplitude can not be correct. What goes wrong here?
RTP oscilloscopes can trigger on signals as small as 1/1000th of a vertical division thanks to digital triggering and adjustable hysteresis. 3 12 RTP, oscilloscope, scope, MSO, update rate, trigger, digital trigger RTP- see the difference. Trigger with highest sensitivity at full bandwidth.
This additional option makes the R&S RTO and RTP oscilloscope to powerful multi-functional debug tools. Video, TDR/TDT, oscilloscopes, RTO, RTP Evaluate impedance and transmission loss of your signal traces with the RTO or RTP oscilloscope's TDR/TDT Analysis option.
17-Sep-2020
Rohde & Schwarz offers bandwidth upgrades for selected oscilloscopes at no extra chargeBandwidth is the most important aspect of an oscilloscope. To support design engineers in current and future design challenges, Rohde & Schwarz is introducing an attractive promotion for selected oscilloscope models: when purchasing an R&S RTO2000 or R&S RTP, now customers can upgrade the bandwidth with no extra costs.
26-Mar-2024
embedded world 2024: Rohde & Schwarz presents its cutting-edge test solutions for embedded systemsRohde & Schwarz offers comprehensive test and measurement solutions for embedded design challenges for today’s requirements for efficiency, safety, reliability and interoperability. The highlights will be showcased at the embedded world Exhibition & Conference 2024 in Nuremberg, Germany.
Models: R&S®RTP-K91, R&S®RTO-K91, R&S®RTO6-K91, R&S®RTP-K93
Models: R&S®RTO-K21, R&S®RTO6-K21, R&S®RTP-K21, R&S®RTP-K102
Models: R&S®RTP-K81, R&S®RTO-K81, R&S®RTO6-K81, R&S®RTP-K83
08-Feb-2021
Rohde & Schwarz introduces the first trigger and decode solution for 1000BASE-T1 automotive EthernetRohde & Schwarz introduces the first trigger and decode solution for 1000BASE-T1 automotive Ethernet.
Volume Adjustment of the "BEEP"
FAQ - Decoding of SENT protocoll shows CRC errors
R&S Scope Suite - eMMC compliance test fails
Connection of DUT and Link partner with test fixture RT-ZF2
Oscilloscope, RTP High-performance oscilloscope, Energy measurement, Pulsed signal, math function Learn how to measure the energy of a pulsed sine wave signal with built-in advanced math functions of the R&S®RTP.
05-Nov-2020
Eurofins partners with Rohde & Schwarz to bring Advanced Testing Kit to High Speed Interface Compliance Test ProgramsEurofins Digital Testing, a global leader in end-to-end quality assurance and testing services, and Rohde & Schwarz, a leading test and measurement expert, are working closely together to give customers access to the latest High-Speed Signal Analysis and Compliance Testing tools using the R&S RTP164 high performance oscilloscope. These will give Eurofins a competitive edge in testing high-speed interoperability. They will further provide certification services for high-speed communications technologies including USB.
When I do RMS measurements and an offset is applied, the result changes. I could not see that effect on other scopes. What is wrong here?
Oscilloscope, RTP High-performance oscilloscope, RF signal analyis, IQ data, RTP-K11, IQ mode Use the IQ mode to downconert and downsample the aquired waveform to IQ data within the oscilloscope for further analysis.
Rohde & Schwarz Manual for Ethernet Compliance Test Fixture R&S®RT-ZF2. Describes the fixture boards and measurement preparations.
Rohde & Schwarz Manual for frequency converter R&S®RT-ZF3.
Rohde & Schwarz Manual for USB 2.0 Compliance Test Fixture Set R&S®RT-ZF1. Describes the fixture boards and measurement preparations.
Programming examples for oscilloscopes.
Video, jitter, oscilloscopes Learn about the novel R&S approach to decomposite the individual jitter components with R&S®RTO or R&S®RTP oscilloscopes in order to gain more inside into your design.
The Rohde & Schwarz manual describes the 1 MOhm high-impedance buffer amplifier for oscilloscopes with 50 ohm input impedance.
Rohde & Schwarz Manual for Ethernet probing fixture R&S®RT-ZF4.
I have exported the waveform into a csv file. When I open the file in Excel, the values are completely wrong. How can I get correct values?
I have compared passive and active probes. It seems that the noise with active probes is higher. What is the reason and what can I do to reduce the noise?
Which test fixture for MDI mode conversion measurement at 100Base T1 Compliance Test?
Learn how to verify the performance of IDT’s RF sampling clock generator / jitter attenuator with low noise signal generator R&S SMA100B and high-performance oscilloscope R&S RTP.
For some tests a vector network analyzer is required. The Scope Suite software just supports VNAs from R&S to be connected via LAN for automated measurements. Can I use also other VNAs and do the measurement manually?