Promo: What's next? Taking industry leadership or watching from the sidelines?

What's next? Taking industry leadership or watching from the sidelines?

Take the lead with up to 60% off our devices!

R&S®NRT2 power reflection meter

Forward and reflection power measurements

R&S®NRT2 power reflection meter
Open Lightbox
R&S®NRT2 power reflection meter
Open Lightbox
R&S®NRT2 power reflection meter
Open Lightbox
R&S®NRT2 power reflection meter
Open Lightbox
R&S®NRT2 power reflection meter
Open Lightbox
R&S®NRT2 power reflection meter
Open Lightbox
R&S®NRT2 power reflection meter, Application Image R&S®NRT2 power reflection meter, front view R&S®NRT2 power reflection meter, front high R&S®NRT2 power reflection meter, side view R&S®NRT2 power reflection meter, back view R&S®NRT2 power reflection meter, hero view

Key facts

  • Simple touchscreen operation
  • Simultaneous display of forward and reverse power
  • Analog bargraph and autoscale
  • Visual limit monitoring
  • 100 % code compatibility with predecessor model

Directional power meter measures forward and reflection power between source and load

Directional power sensors measure forward and reverse power under operating conditions. These measurements are required when installing, servicing and monitoring transmitters, antennas and RF generators. The R&S®NRT family consists of the R&S®NRT2 power reflection meter and various R&S®NRT-Zxx directional power sensors. Thanks to their wide range of measurement functions and high accuracy, they can be used in research, development and production.

Features & benefits

Simple touchscreen operation

Thanks to intelligent menus, the compact R&S®NRT2 base unit with a state-of-the-art 5" touchscreen is extremely easy to operate. On the top menu level, users can switch between the most important measurements. Additional parameters can be set in clearly structured submenus.
Important functions such as setting frequencies, zeroing and taking screenshots can be done at the push of button.

R&S®NRT2 base unit with a 5 inch touchscreen
Open Lightbox

R&S®NRT2 base unit with a 5 inch touchscreen

Simultaneous display of forward and reverse power

The R&S®NRT-Zxx directional power sensors simultaneously measure forward and reverse power and calculate additional parameters such as load matching. The R&S®NRT2;
power reflection meter then displays one forward and one reverse parameter at the same time. Calculated results, such as the amplitude distribution (CCDF) for modulated signals, can also be displayed.

R&S®NRT2 forward measurement functions
Open Lightbox

R&S®NRT2 forward measurement functions

R&S®NRT family

Various sensor models

Directional power sensors measure forward and reverse power under operating conditions. These measurements are required when installing, servicing and monitoring transmitters, antennas and RF generators. The R&S®NRT family consists of the R&S®NRT2 power reflection meter and various R&S®NRT-Zxx directional power sensors.

R&S®NRT2 with a R&S®NRT directional power sensor
Open Lightbox

R&S®NRT2 with a R&S®NRT directional power sensor

Analog bargraph and autoscale

Visual limit monitoring

Measurements can be shown as numeric values or in an analog bargraph. To define the analog measuring range, the autoscale function can be started at the press of a button. The scale of the analog bargraph is optimally adjusted to the measured signal. Each measurement can be visually monitored. Values outside the defined limits are highlighted in red. The analog bargraph also graphically displays the defined limits in red.

Analog bargraph with configurable limits
Open Lightbox

Analog bargraph with configurable limits

100 % code compatibility with predecessor model

The R&S®NRT2 remote commands are 100 % code compatible with the command set of the previous R&S®NRT model. This simplifies device replacement and integration into existing systems (no additional programming required). The R&S®NRT2 power reflection meter can be remote controlled via USB or LAN. The R&S®NRT2-B8 option adds remote control via GPIB (IEEE 488).

100 % code compatibility to the R&S®NRT
Open Lightbox

100 % code compatibility to the R&S®NRT

 R&S®NRT is a phase-out product, replaced by  R&S®NRT2.;

Available options

Base unit
Product
Description
R&S®NRT2-B8

Order number 1430.1505.02

Description

GPIB/IEEE488 interface

Directional power sensors
Product
Description
R&S®NRT-Z14

Order number 1444.0006.02

Description

Directional power sensor

Measurement range AVG:6 mW to 120 W; measurement range PEP:0.4 to 300 W; frequency range:25 MHz to 1 GHz

R&S®NRT-Z44

Order number 1444.0012.02

Description

Directional power sensor

Measurement range AVG:3 mW to 120 W; measurement range PEP:0.4 to 300 W; frequency range:200 MHz to 4 GHz

Recommended extras
Product
Description
R&S®NRT-Z2

Order number 1081.2505.10

Description

Extension cable

10 m extension cable for NRT-Z power sensors

R&S®NRT-Z2

Order number 1081.2505.30

Description

Extension cable

30 m extension cable for NRT-Z power sensors

R&S®NRT-Z5

Order number 1400.6909.02

Description

Interface adapter

USB interface adapter for NRT-Z power sensors

R&S®ZZA-KNA22

Order number 1177.8184.00

Description

19" Adapter BW2010-ADV, 2HU 1/2 + Spare

R&S®ZZA-KNA24

Order number 1177.8149.00

Description

19" Adapter BW2010 Advanced, Cabinet 2HU 1/2 + ½

Documentation
Product
Description
R&S®DCV-1

Order number 0240.2187.06

Description

Documentation of calibration values

R&S®DCV-ZP

Order number 1173.6506.02

Description

Printout of DCV

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.