381 Results
R&S®ScopeSuite Compliance testing of a USB 2.0 device with the R&S®RTO. Test automation with the R&S®RTO-K21 option (R&S®ScopeSuite) Compliance testing of a USB 2.0 device with the R&S®RTO. Test automation with the R&S®RTO-K21 option (R&S®ScopeSuite) USB, Compliance testing, compliance measurements USB 2.0 compliance testing - R&S®ScopeSuite
Minimizing noise was a key goal when designing the R&S®RTO. The result: precise measurements even at the smallest vertical resolutions. Minimizing noise was a key goal when designing the R&S®RTO. The result: precise measurements even at the smallest vertical resolutions Low noise, RTO2000, precise measurements Minimizing noise was a key goal when designing the R&S®RTO.
Oscilloscope bus debugging, RTO2000, bus debugging, RS232 Watch this in depth analysis of RS232 interfaces frame by frame using the R&S®RTO decode table and zoom window.
Discover how to decode SENT, including enhanced serial messages, displayed on an R&S®RTO. Discover how to decode SENT, including enhanced serial messages, displayed on an R&S®RTO. RTO2000, triggering, decoding, fast channel, slow channel, SENT bus, automotive Discover how to decode SENT, including enhanced serial messages, displayed on an R&S®RTO.
RTO2000, decoding, CAN-FD Bus, flexible data, automotive Discover how to decode CAN-FD using a R&S®RTO, as well as looking at transmission errors and electric signal quality.
RTO2000, decoding, CAN Bus, automotive Discover how to decode a CAN Bus with an R&S®RTO, as well as looking at transmission errors and electric signal quality.
A sinus signal with i.e. 10 V peak-peak, frequency 1 MHz is applied. If I choose a vertical scale which is too small the peaks of the waveform are not displayed as they are out of range. Now I activate the digital filter in the “Vertical” menu à “Channel”. The frequency of the filter is also set to 1 MHz. Now even at very small vertical scales (i.e. 50 mV/div) the waveform is displayed completely, see screenshot. But the amplitude can not be correct. What goes wrong here?
The R&S®RTO oscilloscopes’ zone trigger lets you graphically separate events. The R&S®RTO oscilloscopes’ zone trigger lets you graphically separate events. Define up to eight zones of any shape and logically combine them over multiple channels or by using math functions. Zone trigger, time and frequency domain, RTO2000 The R&S®RTO oscilloscopes’ zone trigger lets you graphically separate events.
Expert Talk Oscilloscope: I²C bus decoding Discover how to easily decode I²C with the right setup, as shown on an R&S®RTO. Discover how to easily decode I²C with the right setup, as shown on an R&S®RTO. Oscilloscope bus decoding, RTO2000, bus decoding, I2C Discover how to easily decode I²C with the right setup, as shown on an R&S®RTO.
RTO2000, arbitrary waveform generator Every R&S®RTO can be enhanced to include a 100 MHz arbitrary waveform generator. They offer a fully integrated two-channel 100 MHz function generator, arbitrary waveform generator and eight-channel pattern generator.
Rohde & Schwarz presented the R&S®RTO oscilloscopes at the European Microwave Week 2011. The R&S®RTO combines excellent signal fidelity, high acquisition rate and the world's first realtime digital trigger system with a compact device format. A new standard in user friendliness is offered by the R&S®RTO's remarkably simple touchscreen operation.
This additional option makes the R&S RTO and RTP oscilloscope to powerful multi-functional debug tools. Video, TDR/TDT, oscilloscopes, RTO, RTP Evaluate impedance and transmission loss of your signal traces with the RTO or RTP oscilloscope's TDR/TDT Analysis option.
RTO2000, deep memory, CAN Bus data, decoding, automotive Discover how Rohde and Schwarz oscilloscpes with deep memory can record over a minute of CAN bus data, as displayed on an R&S®RTO.
CAN, trigger, decode, automotive ethernet, RTM, RTO A comparisson between CAN decoding on the R&S®RTM oscilloscope with automotive Ethernet decoding using the K57 option on the R&S®RTO oscilloscope.
Every R&S®RTO can be enhanced to include a mixed signal option. Every R&S®RTO can be enhanced to include a mixed signal option. This enables more signal details thanks to high time resolution over the entire memory depth, as well as precise triggering on signal events. RTO2000, MSO, mixed signal option Every R&S®RTO can be enhanced to include a mixed signal option.
The R&S®RTO can save instrument setups for repetitive measurements. The R&S®RTO can save instrument setups for repetitive measurements. Each instrument setup is saved along with a screenshot of the most recent oscilloscope display. To later select a desired instrument setup, simply scroll through the screenshots to find the right configuration.
The R&S®RTO oscilloscope is the perfect solution for measurement applications that require further remote processing.
15-Feb-2018
Testing LTE MIMO Signals using a R&S RTO Oscilloscope
24-Apr-2013 | AN-No. 1EF86
R&S RTO2000: Documentation at the press of a button R&S®RTO oscilloscopes help you document measurements, including printing and saving screenshots of the screen content, easy to read signal characteristics thanks to clear grid annotations and color-coded labels to highlight anomalies in the diagram.
RTO2000, debugging, AD converter The R&S®RTO-B1 option offers numerous triggers for debugging and analysis, such as edge, width, pattern and serial pattern. The digital channel resolution of 200 ps makes this channel a precise trigger source.
R&S®RTO oscilloscopes offer over 90 measurement functions. R&S®RTO oscilloscopes offer over 90 measurement functions. The functions are organized by type into amplitude and time measurements, jitter, eye, histogram and spectral measurements. Statistics, histograms, and trend and track functions facilitate detailed analysis of the measurement results.
Video, RTO2000, Oscilloscope, Capturing of intermittent RF signals with the Zone Trigger This video demonstrates this unique capability of the R&S®RTO on the example of a frequency hopping signal.
Learn more about wireless IoT technologies, associated test challenges and practical test solutions. video, solution, oscilloscope, RTO The video discusses LoRaWAN, one of the most promising LPWAN technologies. Find out how it works and how to analyze LoRa signals using the R&S®RTO oscilloscope.
RTO2000, SPI, bus decoding, serial protocols R&S®RTO oscilloscopes offer a variety of tools for serial interface analysis. The configuration for any given protocol is accomplished in just a few steps starting from the app cockpit. Just select the bus you want to decode, configure the bus settings and set the reference levels to 50 %.
17-Sep-2020
Rohde & Schwarz offers bandwidth upgrades for selected oscilloscopes at no extra chargeBandwidth is the most important aspect of an oscilloscope. To support design engineers in current and future design challenges, Rohde & Schwarz is introducing an attractive promotion for selected oscilloscope models: when purchasing an R&S RTO2000 or R&S RTP, now customers can upgrade the bandwidth with no extra costs.
The R&S®RTO oscilloscope is a valuable tool for analyzing EMI problems in electronic designs.
27-Jun-2018
A guide to carrying out a 1000BASE-T1 compliance tests with test mode 6 (maximum output droop test) on an R&S®RTO. The video gives an overview of how to configure the setup and generate test reports for further analysis A guide to carrying out a 1000BASE-T1 compliance tests with test mode 6 (maximum output droop test) on an R&S®RTO.
RTO2000 - Error message "Update FPC failed" after firmware update to V5.xx RTO2000 - Error message "Update FPC failed" after firmware update to V5.xx Related Products
In order to clearly visualize and make repeatable measurements on signals with amplitudes of less than 1/100 of a division, and stabilize signals captured over very long periods, the R&S RTO oscilloscope’s powerful combination of measurement and math channel capabilities allows corrective offset adjustments on individual acquisitions more than one hundred times per second.
10-Sep-2015
The R&S®RTO/RTP is perfect for precise measurements in many accelerator physics lab applications, such as in synchrotrons or free electron lasers.
17-Dec-2013