R&S®SMB100A Microwave Signal Generator
Versatile, compact, up to 40 GHz; 170 GHz with upconverter
- Overview
- Models
- Options
- Features & Benefits
-
Microwave Signal Generator
Versatile, compact, up to 40 GHz; 170 GHz with upconverter
-
R&S®SMB-B112 Order No. 1407.2109.02RF Path 100 kHz to 12.75 GHz with electronic step attenuator
-
R&S®SMB-B112L Order No. 1407.2150.02RF Path 100 kHz to 12.75 GHz without step attenuator
-
R&S®SMB-B120 Order No. 1407.2209.02RF Path 100 kHz to 20 GHz, with mechanical step attenuator
-
R&S®SMB-B120L Order No. 1407.2250.02RF Path 100 kHz to 20 GHz, without step attenuator
-
R&S®SMB-B131 Order No. 1407.2280.02RF Path 100 kHz to 31.8 GHz, with mechanical step attenuator
-
R&S®SMB-B140 Order No. 1407.2309.02RF Path 100 kHz to 40 GHz, with mechanical step attenuator
-
R&S®SMB-B140L Order No. 1407.2350.02RF Path 100 kHz to 40 GHz, without step attenuator
-
R&S®SMB-B140N Order No. 1407.2380.02RF Path 100 kHz to 40 GHz, with mechanical step attenuator, minimum pulse width limited
-
R&S®SMB-B1 Order No. 1407.3005.02OCXO Reference Oscillator
Only one of the R&S®SMB-B1 or R&S®SMB-B1H options can be installed.
-
R&S®SMB-B1H Order No. 1407.3070.02OCXO Reference Oscillator, high performance
Only one of the R&S®SMB-B1 or R&S®SMB-B1H options can be installed.
-
R&S®SMB-B25 Order No. 1407.1660.02Harmonic Filter Option
150 MHz to 20 GHz
(only available with R&S®SMB-B120, R&S®SMB-B120L) -
R&S®SMB-B26 Order No. 1407.1760.02Harmonic Filter Option
150 MHz to 40 GHz
(only available with R&S®SMB-B131/-B140/-B140N/-B140L) -
R&S®SMB-B30 Order No. 1407.1160.02Reverse Power Protection, 100 kHz to 12.75 GHz
Only available with an R&S®SMB-B112 or R&S®SMB-112L frequency option.
-
R&S®SMB-B31 Order No. 1407.1260.02High Power Option, 50 MHz to 20 GHz
(only available with R&S®SMB-B120/-B120L)
-
R&S®SMB-B32 Order No. 1407.1360.02High Power Option, 50 MHz to 40 GHz
(only available with R&S®SMB-B131/-B140/-B140N/-B140L)
-
R&S®SMB-K21 Order No. 1407.3811.02Pulse Modulator
for R&S®SMB--B112/-B112L/-B120/-B120L/-B141/-B140/-B140N/-B140L
-
R&S®SMB-K23 Order No. 1407.3786.02Pulse Generator
-
R&S®SMB-K27 Order No. 1407.3828.02Pulse Train
Requires an R&S®SMB-K23 option, only available for instruments with serial number > 102400.
-
19" Rack Adapter
For mounting a 3/4 19" housing 2 RU high in a standard 19" rack
-
R&S®NRP-Z4 Order No. 1146.8001.02 / 1146.8001.04 / 1146.8001.06 / 1146.8001.11USB Adapter (passive)
For all R&S®NRP-Z sensors. The R&S®NRP-Z4 passive USB adapter provides all basic functions, as it handles the transmission of settings and measurement data as well as the power supply of the sensor via the USB bus. Available cable lengths: Available cable lengths: 2.0m, 0.5m and 0.15m Available cable length for panel-mount: 1m
For all R&S®NRP-Z sensors. The R&S®NRPZ4 passive USB adapter provides all basic functions, as it handles the transmission of settings and measurement data as well as the power supply of the sensor via the USB bus. Available cable lengths: Available cable lengths: 2.0m, 0.5m and 0.15m Available cable length for panel-mount: 1m
-
R&S®TS-USB1 Order No. 6124.2531.00USB Serial Adapter for RS-232 remote control
-
Test Port Adapter Order No. 1021.0512.00Test port adapter, PC 3.5 mm female
Adapter for instruments with an
R&S®SMB-B112/-B112L/-B120 or R&S®SMB-B120L frequency option -
Test Port Adapter Order No. 1021.0529.00Test port adapter, PC 3.5 mm male
Adapter for instruments with an
R&S®SMB-B112/-B112L/-B120 or R&S®SMB-B120L frequency option -
Test Port Adapter Order No. 1021.0535.00Test port adapter, N female
Adapter for instruments with an
R&S®SMB-B112/-B112L/-B120 or R&S®SMB-B120L frequency option -
Test Port Adapter Order No. 1021.0541.00Test port adapter, N male
Adapter for instruments with an
R&S®SMB-B112/-B112L/-B120 or R&S®SMB-B120L frequency option -
Test Port Adapter Order No. 1088.1627.02Test port adapter, 2.4 mm female
Adapters for instruments with an R&S®SMB-B131/-B140/-B140N/-B140L frequency option
-
Test Port Adapter Order No. 1036.4790.00Test port adapter, 2.92 mm female
Adapters for instruments with an R&S®SMB-B131/-B140/-B140N/-B140L frequency option
-
Test Port Adapter Order No. 1036.4802.00Test port adapter, 2.92 male
Adapters for instruments with an R&S®SMB-B131/-B140/-B140N/-B140L frequency option
-
Test Port Adapter Order No. 1036.4777.00Test port adapter, N female
Adapters for instruments with an R&S®SMB-B131/-B140/-B140N/-B140L frequency option
-
Test Port Adapter Order No. 1036.4783.00Test port adapter, N male
Adapters for instruments with an R&S®SMB-B131/-B140/-B140N/-B140L frequency option
-
R&S®SMZ75 Order No. 1417.4004.02Frequency Multiplier, 50 GHz to 75 GHz
-
R&S®SMZ90 Order No. 1417.4504.02Frequency Multiplier, 60 GHz to 90 GHz
-
R&S®SMZ110 Order No. 1417.5000.02Frequency Multiplier, 75 GHz to 110 GHz
-
R&S®SMZ170 Order No. 1417.5500.02Frequency Multiplier, 110 GHz to 170 GHz
-
R&S®SMZ-B75M Order No. 1417.6007.02Mechanically Controlled Attenuator for the R&S®SMZ75
-
R&S®SMZ-B75E Order No. 1417.6107.02Electronically Controlled Attenuator for the R&S®SMZ75
-
R&S®SMZ-B90M Order No. 1417.6507.02Mechanically Controlled Attenuator for the R&S®SMZ90
-
R&S®SMZ-B90E Order No. 1417.6607.02Electronically Controlled Attenuator for the R&S®SMZ90
-
R&S®SMZ-B110M Order No. 1417.7003.02Mechanically Controlled Attenuator for the R&S®SMZ110
-
R&S®SMZ-B110E Order No. 1417.7103.02Electronically Controlled Attenuator for the R&S®SMZ110
-
R&S®DCV-2 Order No. 0240.2193.09Documentation of calibration values
-
R&S®SMB100A Order No. 3596.9508.03Accredited Calibration
-
R&S®WE1SMB100AExtended Warranty, one year
-
R&S®WE2SMB100AExtended Warranty, two years
-
R&S®WE3SMB100AExtended Warranty, three years
-
R&S®WE4SMB100AExtended Warranty, four years
-
R&S®CW1SMB100AExtended Warranty with Calibration Coverage, one year
-
R&S®CW2SMB100AExtended Warranty with Calibration Coverage, two years
-
R&S®CW3SMB100AExtended Warranty with Calibration Coverage, three years
-
R&S®CW4SMB100AExtended Warranty with Calibration Coverage, four years