I am using the burst function of the function generator. But I can not find the remote command to set the burst to "manual".
I want to configure the arbitrary function of the waveform generator using CSV files. But I can not find any information about the file format.
Programming examples for oscilloscopes.
Saving a screenshot to an USB stick with remote commands
R&S®RTM3000 Digital Oscilloscope - Fact Sheet Brochures and Data Sheets
R&S®RTM3000 Oscilloscope - Specifications Brochures and Data Sheets Specifications
R&S®RTM3000 versus Tektronix MDO3000 - Comparison Sheet Brochures and Data Sheets
R&S®RTM3000 versus LeCroy WS3000 - Comparison Sheet Brochures and Data Sheets
R&S®RTM3000 versus Keysight InfiniiVision 3000T - Comparison Sheet Brochures and Data Sheets
R&S®RTM3000 versus Tektronix 3 Series MDO - Comparison Sheet Brochures and Data Sheets
R&S RTM Digital Oscilloscope - Product brochure Digital oscilloscopes for fast signal analysis, finding signal faults quickly and effectively, triggering and decoding of serial protocols.
RTB/RTM/RTA - reduce Stop Frequency at FFT
RTM/RTA: Measurement on several pulses of a train.
RTB, RTM, RTA: Acquire Mode "High Resolution" looses details?
I want to install the RTB / RTM / RTA into a rack and I use the rackmount kit "ZZA-RTB2K". Is the ground of the oscilloscope then connected to the frame of the rack?
TM/RTA - Edge A/B Trigger - Remote commands for the trigger level
With active FFT it seems that the timebase setting can not be changed. Is there a way to do that?
I have saved some important screenshots in /INT/SCREEN path. Now I want to save/copy these data on a USB key or my PC.
What is the calculation base for the sample rate on my R&S RTA / RTM series scope when using FFT?
I do RMS measurement on a signal after switching the channels. Even with *OPC? or *WAI the result is implausible: 9.91e+37 . How can I get a correct result?
I want to use the "Remote Display" function of the Instrument View software. Instead of the screen I just see a "white" area. My PC is connected via USB. How can I use it?
When I query the waveform with "CHANx:DATA?" the resolution is just that what is displayed on the screen. But I have manually changed the record length to achieve a high resolution. How do I get the data of the waveform with full resolution?
RTB/RTM/RTA: Other units than V or A at channels? RTB, TRM, RTA, RTB/RTM/RTA: Other units than V or A at channels? RTB, TRM, RTA, Related Products
Cursors that follow the waveform
No synchronisation in Auto Trigger Mode
Delta Time Accuracy Calculation for my Oscilloscope
How can I find out that the measurement has been finished?
Configuring the Probe Adapter RT-Z2T with remote commands
How can I query the waveform data of the serveral segments?