Excellent technical specifications have been a distinguishing mark of Rohde & Schwarz EMI test receivers right from the beginning. Each R&S®ESIB model continues this tradition with the following characteristics:
Frequency range | |
Input 1 | 20 Hz to 7 GHz / 26.5 GHz / 40 GHz depending on model |
Input 2 | 20 Hz to 1 GHz |
Preselection | 9 or 10 preselection filters depending on model can be switched off in analyzer mode |
Resolution bandwidths (receiver and analyzer mode) | |
6 dB bandwidths EMI bandwidths |
10 Hz to 10 MHz, in decimal steps 200 Hz, 9 kHz, 120 kHz, 1 MHz acc. to CISPR 16 tolerance |
Resolution bandwidths (analyzer mode) | |
3 dB bandwidths | 1 Hz to 10 MHz, in steps 1/2/3/5 |
Displayed average noise level | ||
Receiver mode; 0 dB RF attn.; preamp. 20 dB |
R&S ESIB7 | R&S ESIB26 / 40 |
9 kHz to 150 kHz (RBW 200 Hz) | –10 to –24 dBμV | –10 to –24 dBμV |
0.15 MHz to 30 MHz (RBW 9 kHz) | –7 to –17 dBμV | –7 to –17 dBμV |
30 MHz to 1000 MHz (RBW 120 kHz) | <–6 dBµV | <–3 dBµV |
1 GHz to 7 GHz (RBW 1 MHz) | <6 to 9 dBμV | <9 to 12 dBμV |
7 GHz to 26.5 GHz (RBW 1 MHz) |
–
|
<4 to 6 dBμV/6 to 9 dBμV |
26.5 GHz to 40 GHz (RBW 1 MHz) |
–
|
– /20 to 26 dBμV |
Max. dynamic range (BW 1 Hz) | ||
1 dB compr. point/displayed noise floor | 162 dB | 160 dB |
Total level uncertainty (preamp. off) | ||
Analyzer mode | ≤ 1 GHz 1 GHz to 7 GHz |
≤ 0.5 dB ≤ 1.0 dB |
Receiver mode | 150 kHz to 1 GHz 1 GHz to 4.5 GHz 4.5 GHz to 7 GHz |
≤ 1.0 dB ≤ 2.0 dB ≤ 2.5 dB |
Measurement speed | |
Sweep (analyzer mode) | 1 µs to 2.500 s (zero span) 5 ms to 1.000 s (span ≥ 10 Hz) |
Scan (receiver mode) | 100 μs to 1.000 s |
Max. input level | |
RF attn. ≥ 10 dB; sinewave AC voltage | 137 dBμV (= 1 W) |
Max. input pulse voltage (10 µs) | |
Input 2 (≤1 GHz); RF attn. ≥ 10 dB | 1.500 V for the R&S ESIB7 250 V for the R&S ESIB26/40 |