Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
1106 Results
Sequencer Software Tool
20-Feb-2015
This application note describes Methods of Implementation (MOI) for precise, fast, and error-free compliance testing of USB 3.2 Legacy Cable Testing for USB Type A, Type B, and Micro family connector types. Based on 5 Gbps and 10 Gbps signaling per lane with vector network analyzers from Rohde & Schwarz.
09-Nov-2023 | AN-No. 1SL408
Describtion and explanation of the MPEG and DVB-Standards and TV T&M
10-Dec-2011 | AN-No. 7BM_ADD01
Embedded power supplies combine traditional power supply components with multiple sensors, processing and control logic as well as digital communications interfaces. Test equipment for debugging requires isolated input channels for measurements of hazardous voltages. Additional digital channels support the analysis of digital signals, while trigger and decode capabilities are essential for time-correlated monitoring of serial protocol-based communications interfaces.
26-Apr-2016
Short test times in conjunction with accurate and repeatable measurement results are essential when testing and calibrating mobile phones at board level. The R&S FSP Spectrum Analyzer offers wide dynamic range, stable and accurate results within shortest sweep time, making it the ideal choice for high-volume production testing. The utilisation of both the list mode feature and the marker list function for the Spectrum Analyzer R&S FSP, with its unsurpassed measurement speed via remote control are demonstrated in this application note.
29-Aug-2003 | AN-No. 1MA65
To quantify uncertainties for network analyzer measurements, the influence of the entire system (network analyzer plus test setup and DUT) has to be taken into account. Usually, the overall uncertainty of the complete measurement setup is determined with the aid of a verification kit, containing highly accurate verification standards. Of course, the verification standards need to have the same connector type as the DUT. If such verification standards are not available, the overall error has to be estimated.
28-Jul-1998 | AN-No. 1EZ29
Voice over IP for air traffic control
15-Oct-2012
A programmable data generator such as the combination of SME with option SME-B11 is a novelty with signal generators. To make it easy for the user to get acquainted with the option and to ensure efficient operation, possible applications are described below. The data generator is used for producing binary data as well as control signals for level switching whenever digitally modulated signals are used. For a start we should like to deal in brief with the various settings available for digital modulation. Taking GSM as an example, the programming of data lists will be described next. The description for GSM can be easily applied to other digital networks as well. Next the generation of level bursts and the extension of data generator memory with option SME-B12 are described. The last section deals with special subjects such as FSK using data rates below 400 bits/s and pulse-amplitude modulation. A basic knowledge on digital modulation and TDMA will be sufficient to follow the topics.
01-Jul-1999 | AN-No. 1GPAN08
The numerous supply voltages of FPGAs, CPUs and DSPs need to be powered-up in a specific order to ensure reliable operation. It is crucial to verify this power sequencing during circuit design and product development.
08-Oct-2018
DC power supplies from Rohde & Schwarz can be connected and configured for synchronized on/off switching of all channels across multiple power supplies in intricate and complex systems.
28-Apr-2023
Many measurements in audio applications have to be monitored for compliance with specified limit values. Therefore, sometimes a whole series of measurements have to be compared with a fixed limit value, in other case it might be necessary to define different tolerances for example for different frequency ranges. Both can be done using Audio Analyzer UPD or UPL. This application note covers the different possibilities of limit checking, it demonstrates how to edit limit files and presents a program to easily generate files for checking the limits of frequency response measurements. Furthermore the display modes for different kinds of references are explained.
04-Jun-1998 | AN-No. 1GA33
In the T&M world, instrument remote control over SNMP (simple network management protocol) lives in the shadow of IEEE/GPIB (general purpose interface bus) based remote control, and only a handful of the T&M equipment available worldwide supports the protocol. It is therefore no surprise that for most T&M engineers familiar with text-based commands over IEEE/GPIB (and lately LAN), the SNMP protocol seems a bit odd and to some even complex at first. The SNMP Toolkit for LabVIEW™ from Viodia™ Inc. can save a considerable amount of development time and furthermore helps programmers to overcome the initial complexities of SNMP programming.
18-Oct-2007 | AN-No. 7BM70
The R&S®FSW signal and spectrum analyzer is a high-performance instrument capable of measuring many key system and component parameters. Using the bit error rate (BER) functionality of the R&S®FSW-K70P option, the raw data error performance of a component or system can be accurately determined.
26-Sep-2018
This R&S®CMU200 1xEV-DO Release B non-signaling testing application provides the means to allow users to perform RF measurements on a 1xEV-DO Rel. B access terminal in a mode that does not require any signaling. This allows the calibration and final tests of a Rel. B AT, according to the minimum performance standards with the R&S®CMU200.
29-Jun-2009 | AN-No. 1CM74
Broadband amplifiers are necessary for generating the field strengths required for most EMC radiated immunity tests. This Educational Note provides a brief overview of the role of amplifiers in EMC testing as well as a discussion of the parameters and characteristics which have the greatest influence on amplifier performance.Register now to download the Educational Note.
01-Aug-2022
For automated test applications, measurement time is often as important as the quality of the measurement. As with many situations, time is money. In practice, phase noise measurements are generally not considered fast, but test engineers still desire to save as much test time as possible. The Rohde & Schwarz®FSWP (FSWP) is a modern, digital signal processing based, phase-noise test set that performs many tasks in parallel in an effort to improve measurements speed. However, several measurement settings drastically affect measurement speed. This paper will discuss these settings and provide suggestions on improving overall measurement speed.The three key instrument parameters that affect FSWP measurement speed are:1. Number of cross correlations2. Resolution bandwidth (RBW)3. Offset frequency span
08-Oct-2020 | AN-No. GFM354
This Application Note describes measurements on RFID readers and chipcards according to ISO/IEC 14443 and similar standards, using a signal generator and a spectrum analyzer. Using a modern spectrum analyzer like the R&S®FSL not only increases accuracy and measurement speed, but also simplifies operation. Interoperability tests, in particular, are simplified by generating reader test signals with a signal generator. With software option R&S®SMx/AMU/AFQ-K6 chipcards can be tested without a reader
25-Jan-2010 | AN-No. 1MA113
Software tools allow to make the control of T&M instruments more convenient. The adoption of the following tools for Windows®-based T&M instruments is described: ● Synergy:One mouse and one keyboard control a group of T&M instruments ● CamStudio:Video clips of the display of a T&M instrumentare recorded during operation
13-Jun-2013 | AN-No. 1MA218
Stable operation in all circumstances is essential for power converters. Different working conditions, such as load steps, startup/shutdown sequences and input voltage variation, apply to most converter types. In addition to the standard feedback control loop, integrated pulse width modulation (PWM) controllers provide extended functions, such as line feed-forward loop control and soft-start control. These extended control functions improve regulation for specific conditions. Such complex regulation systems require smart methods to ensure proper operation of the converter in all modes. For this task, extensive expertise and the right measurement tools are essential for identifying and locating unexpected events in the system.
11-Oct-2023
The R&S®EB500 offers level measurement of signals with 20 MHz bandwidth.
09-Oct-2012
Load pull is a powerful method for characterizing RF power amplifiers through impedance variation. Load pull enables model extraction and validation as well as performance, ruggedness and efficiency testing.
02-Sep-2020
This application note highlights various aeronautical radio navigation signals such as VHF omnidirectional radio range (VOR), instrument landing system (ILS) for glide slope (GS) and localizer (LLZ), as well as marker beacon (MB). Rohde & Schwarz test and measurement solutions for avionics navigation equipment are introduced based on application scenarios, including calibration, research and development, field tests, and transceiver testing.
01-Feb-2012 | AN-No. 1MA193
The R&S MATLAB® Toolkit for Signal Generators provides routines for remote controlling these instruments. Additional MATLAB® scripts turn I/Q vectors into the Rohde & Schwarz waveform file format for use with an ARB. This application note describes the installation and use of the R&S MATLAB® Toolkit on Microsoft Widows and Linux based systems.
26-Apr-2013 | AN-No. 1GP60
Since the video signal - composite or component - is a most complex one regarding the spectral density or even the group delay in the baseband, you need special procedures to measure the signal parameters with an objective and absolute accuracy of less than one percent over the whole frequency range up to 6 MHz. The following describes a method allowing the precise measurement of a baseband signal, which then may be taken for the calibration of video analyzers such as the well-known R&S units UAF or UVF and future products.
20-Jul-2001 | AN-No. 7BM22
This application note describes how to generate cdma2000® signals for wide ranging receiver tests under fading conditions for cdma2000® 450/Cellular/PCS/IMT-2000 mobile and base station equipment. The test setup requires an Rohde & Schwarz Universal Radio Communication Tester CMU with IQ-IF interface option CMU-B17 and a baseband fading simulator ABFS. The cdma2kFadLevCor program included with this application note performs a semi automatic level correction of the power fed to the Device Under Test (DUT).
21-Jan-2005 | AN-No. 1MA64
Starting from June 2017, almost all radio transmitters and receivers sold or put into operation in the European Union have to be tested for immunity against interferers in adjacent frequency bands. ETSI standard EN 303 340 defines the tests to be performed on digital television receivers and requirements to be passed.This application note describes the test procedures and provides save-recall files and interferer signals for the Broadcast Test Center R&S®BTC.
11-Jul-2017 | AN-No. 1GP116
The R&S®EVSG1000 and R&S®EVSF1000 are signal level and modulation analyzers that reliably analyze GBAS systems during ground and flight inspection when used together with the R&S®EVSG-K4 option.
27-Jun-2019
This application note shows how to configure the R&S®AdVISE visual inspection software to automate the immunity testing in line with EN 55020 and CISPR 35 on TV sets and monitors.
30-Jul-2020 | AN-No. 1S007
Noise-Power-Ratio (NPR) measurements are a common procedure and a simple but useful tool to characterize the performance of power amplifiers for satellites or other multi-channel communication systems. The main advantage is the use of wideband signals like noise, multi-carrier CW tones or I/Q modulated signals, which leads to a better simulation of the real environment. This application note provides information how to generate these signals with a vector signal generator and perform NPR measurements with spectrum analyzers. With the R&S®SMW200A vector signal generator any desired test signal can be created. The R&S®FSW spectrum and signal analyzer offers an automated function for NPR measurements. The limiting factors of both a vector signal generator and a spectrum analyzer are explained. Measurement examples show the practical results of NPR measurements.
24-Jun-2019 | AN-No. 1EF108