R&S®HX002A1 Antenna

150 W HF Dipole

This is a discontinued product
Please note the following successor product(s):
  • Overview

Key Facts

The HF Dipole R&S®HX002A1 is highly suitable for setting up radio links over any distance range. The antenna design ensures high transmission reliability over short and medium distances.

Features

  • Omnidirectional coverage with high-angle radiation (NVIS)
  • No skip zone
  • Automatic adaptive operation

Specifications

Model Frequency range
R&S®HX002A1 Antenna 1.5 MHz to 30 MHz

Key Facts

  • 1.5 MHz to 30 MHz
  • HF dipole with integrated antenna tuning unit for all distance ranges

    The HF Dipole R&S®HX002A1 is highly suitable for setting up radio links over any distance range. The antenna design ensures high transmission reliability over short and medium distances. The antenna can easily be integrated in existing systems since no control lines are required. All control signals and the power for the ATU are fed via the coaxial cable. The HF Dipole R&S®HX002A1 can be directly connected to the HF Transceiver R&S®XK2100.

    The automatic adaptive behaviour of the integrated antenna tuning unit allows antennas to be set up close to neighboring antenna systems and on difficult terrain (e.g. built-on roofs).

  • Recommended extras
    • 5-m tiltable mast for roof mounting R&S®KM002A1
    • 15m Lattice Mast R&S®KM451B2
    • Mast Adapter for 15m Mast

Features & Benefits

  • Omnidirectional coverage with high-angle radiation (NVIS)
  • No skip zone
  • Automatic adaptive operation
  • Silent tuning
  • No control line required
  • Can be set up close to neighboring antennas

Specifications

R&S®HX002A1
Frequency range 1.5 MHz to 30 MHz
Polarization linear/horizontal
Input impedance 50 Ω
VSWR <1.5 (typ. <1.3)
Max. input power 100 W CW/150 W PEP
Tuning time
Without retuning typ. 200 ms
Initial tuning <=6 s (typ. 3 s)
Silent tuning <30 ms
Tuning power
With transmitters from Rohde & Schwarz 30 W to 100 W
Efficiency approx. 25 % to 98 %
Gain (6 m above perfectly conducting ground) –12 dBi to 8 dBi (typ.)
ATU supply (provided by Transceiver) 21 V to 31 V DC (typ. 1 A at 24 V DC)
Connector N female
MTBF >8000 h
Operating temperature range –25 °C to +55 °C
Max. wind speed
Without ice deposit 250 km/h
With 20 mm radial ice deposit 130 km/h
Dimensions
Length × width (dipole) approx. 10.7 m × 4.4 m
Height of ATU approx. 0.42 m
Weight approx. 37.5 kg
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Get a Demo

Please enter your inquiry.
Please enter your first name.
Please enter your name.
Please enter a valid email address.
Please enter your company name.
Please enter your city name.
Please enter your postal code.

Please enter your location.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

Please enter the characters shown in the image
show captcha
The input was not correct.
Do not enter data in this field
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Get a Quote

Please enter your inquiry.
Please enter your first name.
Please enter your name.
Please enter a valid email address.
Please enter your company name.
Please enter your city name.
Please enter your postal code.
Please enter your phone number.

Please enter your location.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

Please enter the characters shown in the image
show captcha
The input was not correct.
Do not enter data in this field
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Request information

Please enter your inquiry.
Please enter your first name.
Please enter your name.
Please enter a valid email address.
Please enter your company name.
Please enter your city name.
Please enter your postal code.

Please enter your location.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

Please enter the characters shown in the image
show captcha
The input was not correct.
Do not enter data in this field
International Website