Frequency range |
|
9 kHz to 225 MHz instantaneously |
Nominal output load |
|
50 Ω |
Nominal power |
|
3000 W (64.8 dBm), 5000 W (67 dBm), 10000 W (70 dBm) |
Modulation capability |
|
AM, FM, φM, PM |
Nominal power gain |
3000 W model |
68.2 dB |
|
5000 W model |
70.4 dB |
|
10 000 W model |
73.4 dB |
Gain flatness |
|
±3.0 dB |
Gain adjustment range |
|
> 15 dB |
Harmonics |
3000 W model 9 kHz to 110 MHz at 3000 W 110 MHz to 225 MHz at 2800 W |
< –20 dBc |
|
5000 W model 9 kHz to 110 MHz at 5000 W 110 MHz to 225 MHz at 3500 W |
< –20 dBc |
|
10000 W model 9 kHz to 110 MHz at 10000 W 110 MHz to 225 MHz at 8000 W |
< –20 dBc |
Spurious |
carrier offset > 100 kHz, starting at 1 MHz |
–80 dBc (nom.), max. –70 dBc |
Noise figure |
at maximum gain |
|
|
5 kHz to 50 MHz |
< 16.0 dB (nom.) |
|
50 MHz to 225 MHz |
< 9.0 dB (nom.) |
Nominal input impedance |
|
50 Ω |
Input level for nominal output power |
|
–3.4 dBm |
Input VSWR |
into 50 Ω |
max. 2:1 |
Maximum input level |
RF |
+5 dBm |
|
DC |
0 V |
Nominal output impedance |
|
50 Ω |
Nominal forward output power |
at VSWR < 6:1 |
continuous, without foldback |
|
at VSWR > 6:1 |
continuous, with gradual foldback to approx. 50% of output power, depending on load impedance |
Output mismatch protection, VSWR |
|
100%, without damage |
RF sample and detected RF sample signals
|
RF sample signal coupling factor |
RF forward and reflected sample ports, optional |
ca. 70 dB (see test report for details) |
Detected sample signal level |
detected forward and reflected sample ports, optional |
to 3.0 V DC (see test report for details) |
Mechanical specifications of amplifier system
|
Dimensions |
rack setup, W × H × D, incl. handles, stands and crane lugs |
|
3000 W model |
600 mm × 1570 mm × 1100 mm (23.62 in × 61.81 in × 43.31 in) |
|
5000 W model |
600 mm × 2050 mm × 1100 mm (23.62 in × 80.71 in × 43.31 in) |
|
10 000 W model |
1200 mm × 2050 mm × 1100 mm (47.24 in × 80.71 in × 43.31 in) |
Mechanical specifications of heat exchanger
|
Dimensions |
W × H × D, incl. handles and stands |
|
|
3000 W model |
1241 mm × 558 mm × 400 mm (48.86 in × 21.97 in × 15.75 in) |
|
5000 W model |
1125 mm × 925 mm × 600 mm (44.29 in × 36.42 in × 23.62 in) |
|
10 000 W model |
2400 mm × 1150 mm × 600 mm (94.49 in × 45.27 in × 23.62 in) |
Connectors
|
Connecting plate at rack top cover or at bottom of rear pane |
RF input port |
N female |
|
sample ports, for RF or detected RF |
N female |
|
Ethernet |
RJ-45 |
|
interlock |
WAGO X-COM®, 7‑pin, female |
|
amplifier state |
WAGO X-COM®, 7‑pin, female |
|
transparent I/O, optional |
2 × WAGO X-COM®, 7‑pin, female |
RF output port |
rear panel, bottom |
1 5/8" EIA female |
Mains power |
rear panel, bottom |
|
3000 W model |
5 × 4 mm2 power cord |
|
5000 W model |
5 × 10 mm2 power cord |
|
10000 W model |
5 × 16 mm2 power cord |
Coolant supply |
|
rack top cover, rear panel or rack shelf |
Electrical specifications of amplifier system
|
Nominal operating voltage ranges |
3000 W model, 5000 W model, 10 000 W model |
380 V to 415 V AC ± 10%, three-phase with N, 50 Hz to 60 Hz ± 6 % |
|
3000 W model, 5000 W model |
208 V to 240 V AC ± 10%, three-phase, 50 Hz to 60 Hz ± 6% |
Nominal current |
3000 W model, at 230 V, per phase |
< 20.5 A |
|
5000 W model, at 230 V, per phase |
< 35 A |
|
10 000 W model, at 230 V, per phase |
< 72 A |
Nominal power |
3000 W model, RFcw = 3000 W (RMS), VSWR = 1 |
< 14.2 kVA |
|
5000 W model, RFcw = 5000 W (RMS), VSWR = 1 |
< 24 kVA |
|
10 000 W model, RFcw = 10 000 W (RMS), VSWR = 1 |
< 50 kVA |
Electrical specifications of heat exchanger
|
Nominal operating voltage range |
|
230 V AC ± 10 %, single-phase, 50 Hz bis 60 Hz ± 6 % |
Current at 230 V |
3000 W model |
< 1.5 A |
|
5000 W model |
< 3.5 A |
|
10 000 W model |
< 13 A |
Power consumption |
3000 W model |
< 350 VA |
|
5000 W model |
< 810 VA |
|
10 000 W model |
< 3000 VA |
Cooling specifications
|
Cooling circuit |
|
closed cooling system, automatic pressure balancing |
Coolant |
|
39 % v/v Antifrogen® N (based on monoethylene glycol, water and anticorrosion additives) |
Heat exchanger |
capacity |
|
3000 W model |
max. 9.5 kW |
|
5000 W model |
max. 15.7 kW |
|
10 000 W model |
max. 41 kW |
|
air volume flow |
|
3000 W model |
6200 m3/h |
|
5000 W model |
5145 m3/h |
|
10 000 W model |
20100 m3/h |
|
mounting type |
indoor or outdoor, floor installation |
Recommended distance between amplifier system and heat exchanger |
pipe length |
max. 2 × 20 m |
|
difference in altitude |
max. 20 m |
Cooling hose |
outside diameter |
|
3000 W model, 5000 W model |
2 × 40 mm (2 × 1.57 in) |
|
10000 W model |
2 × 51 mm (2 × 2.0 in) |
|
bending radius |
280 mm (11 in) |
Graphical user interface
|
Local display |
|
200 × 48 pixel, monochrom |
Web-GUI |
via Ethernet |
RJ-45, 10/100 Mbit/s, autonegotiation, half/full duplex |
Remote control
|
Ethernet |
|
RJ-45, 10/100 Mbit/s, autonegotiation, half/full duplex |
Environmental conditions
|
Temperature loading |
operating temperature range |
0 °C bis +40 °C |
|
storage temperature range |
–20 °C bis +70 °C |
Damp heat |
|
max. +40 °C at 95 % rel. humidity, without condensation |
Altitude |
operating altitude |
up to 2000 m |
|
storage altitude |
up to 4600 m |
Protection
|
Load VSWR |
|
unlimited |
Interlock |
|
1 device interlock, 1 configurable interlock |
Input protection against bias voltage |
optional |
DC block level ≤ 50 V DC |
Transient voltage compatibility |
|
category II, in line with IEC 60364-4-443 |
Switching capacity of internal fuses |
|
< 10 kA |
Thermal overload |
|
shutdown at thermal overload (+50 °C ambient temperature) |
Pressure overload |
|
pressure relief valve, 5 bar |
Module exchange |
|
self-shutting valves |