156 Results
Calibrating a vector network analyzer (VNA) with different connectors on each port
Converting the real and imaginary numbers to magnitude in dB and phase in degrees.
R&S ZVA110 Vector Network Analyzer System - Specifications
R&S®ZVAX-TRM Instrument Security Manual
Sending a remote Control Command internally
What is the correct pin layout of the DC inputs on the network analyzer's rear panel?
R&S®ZVAX-TRM User Manual
R&S ZCxxx Converter Power Supply User Manual
R&S®ZVAX24 Quick Start Guide
Use the R&S®ZVA vector network analyzer and R&S®BBA150 broadband amplifier for accurate and reproducible results in minimum test time.
27-Sep-2013
I have set my VNA to single sweep mode and switched on averaging with a factor of 10. But when I restart the single sweep, it stops after 1 sweep and the averaging is not done.
R&S®ZVA-Zxx Millimeter Wave Converters - Product Brochure
S-Parameters of a 50 to 75 Ohm impedance matching device using R&S ZVx VNA
06-May-2009 | AN-No. 1EZ59
Rohde & Schwarz Getting Started for the R&S ZCxxx frequency converters
R&S®ZVA Vector Network Analyzer - Product Brochure
Noise Figure Measurement without a Noise Source on a Vector Network Analyzer
27-Oct-2010 | AN-No. 1EZ61
I trigger this single sweep with the RSZVB_Send_Trigger_and_Wait_for_OPC driver, but this driver does not wait for the complete 10 sweeps. If I don't use averaging, this program is works.
I query the values of a trace using scpi commands. But I get the y-values only. Is there a possibility to get the y-values also (frequency)?
How can I switch from remote to local state via remote control?
TDR, TDT, ZVA vector network analyzer This video series demonstrates the calibration of a four-port network analyzer and the measurement of rise time, impedance vs. distance and skew on a board with differential lines
Testing S-Parameters on Pulsed Radar Power Amplifier Modules
11-Apr-2013 | AN-No. 1MA126
This application notes introduces two alternative methods how to do the Power Added Efficiency measurement.
22-May-2013 | AN-No. 1EZ64
I have used my TRL calibration kit with my ZVA before. Now I want to use also with my ZNB. But when I try to load the data of the calibration kit into the ZNB, the above error message is shown.
How do I calculate these frequency points when I have a logarithmic sweep and know the center frequency, the span and the number of sweep points?
R&S ZV-WR02/WR03/-WR05 Technical Information
TDR, TDT, ZVA vector network analyzer, This video series demonstrates the calibration of a four-port network analyzer and the measurement of rise time, impedance vs. distance and skew on a board with differential lines.
TDR, TDT, ZVA vector network analyzer This video series demonstrates the calibration of a four-port network analyzer and the measurement of rise time, impedance vs. distance and skew on a board with differential lines.
The R&S®ZVA vector network analyzer in combination with the R&S®ZVAB-K30 noise figure measurement option simplifies noise figure measurement, a key parameter for receiver performance evaluation.
TDR, TDT, ZVA vector network analyzer, This video series demonstrates the calibration of a four-port network analyzer and the measurement of rise time, impedance vs. distance and skew on a board with differential lines.