R&S®FS-Zxx Harmonic mixers

for the R&S®FSW/FSV/FSVA/FSVR/FSWP

Key facts

  • Low conversion loss
  • High 1 dB compression point
  • High LO frequency range

Brief description

The R&S®FS-Z60 / R&S®FS-Z75 / R&S®FS-Z90 / R&S®FS-Z110 / R&S®FS-Z140 / R&S®FS-Z170 / R&S®FS-Z220 / R&S®FS-Z325 / R&S®FS-Z500 harmonic mixers extend the frequency range of Rohde & Schwarz analyzers up to 500 GHz.

Features

  • High sensitivity
  • High large-signal immunity
  • Straightforward spectrum display

Specifications

Model Frequency range
R&S®FS-Z60 40 GHz to 60 GHz
R&S®FS-Z75 50 GHz to 75 GHz
R&S®FS-Z90 60 GHz to 90 GHz
R&S®FS-Z110 75 GHz to 110 GHz

Key facts

  • Low conversion loss
  • High 1 dB compression point
  • High LO frequency range
  • No biasing required
  • Conversion loss data provided in file format

Brief description

The R&S®FS-Z60 / R&S®FS-Z75 / R&S®FS-Z90 / R&S®FS-Z110 / R&S®FS-Z140 / R&S®FS-Z170 / R&S®FS-Z220 / R&S®FS-Z325 / R&S®FS-Z500 harmonic mixers extend the frequency range of Rohde & Schwarz analyzers up to 500 GHz.

Due to their double-diode design, the mixers are operated without any additional biasing. No frequency dependent adjustment of bias current is needed – an invaluable feature for automated measurements. The frequency dependent conversion loss is calibrated over the entire frequency range. The large number of frequency points included in the resulting conversion loss table provides high level accuracy during measurements. The conversion loss table comes in file format with each mixer and can be loaded directly into the analyzer, which makes mixer configuration very easy.

All analyzer models offering the LO/IF ports for external mixers support the harmonic mixers (B21 option required).

features & benefits

High sensitivity

The low conversion loss yields high sensitivity, which is the basis for measuring signals even at very low levels.

High large-signal immunity

With a high 1 dB compression point and low conversion loss, the mixers feature a very wide dynamic range. Therefore, measurements of low-level signals can easily be performed even in the presence of high-level signals.

Straightforward spectrum display

The high LO frequency range and the low order of harmonics used significantly reduce the number of unwanted mixing products. In addition, the analyzer firmware provides algorithms to identify and suppress remaining unwanted mixing products.

Wideband Signal Analysis

The models R&S®FS-Z75, R&S®FS-Z90 and R&S®FS-Z110 GHz have a higher IF OUT frequency range (IF OUT) of 5 MHz to 6.0 GHz that enables an analysis bandwidth of more than 5 GHz.

Specifications

Model Frequency range
R&S®FS-Z60 40 GHz to 60 GHz
R&S®FS-Z75 50 GHz to 75 GHz
R&S®FS-Z90 60 GHz to 90 GHz
R&S®FS-Z110 75 GHz to 110 GHz
R&S®FS-Z140 90 GHz to 140 GHz
R&S®FS-Z170 110 GHz to 170 GHz
R&S®FS-Z220 140 GHz to 220 GHz
R&S®FS-Z325 220 GHz to 325 GHz
R&S®FS-Z500 325 GHz to 500 GHz