R&S®RTA4000 Oscilloscope

R&S®RTA4000 Oscilloscope
Open Lightbox
R&S®RTA4000 Oscilloscope
Open Lightbox
R&S®RTA4000 Oscilloscope
Open Lightbox
R&S®RTA4000 Oscilloscope
Open Lightbox
R&S®RTA4000 Oscilloscope
Open Lightbox
R&S®RTA4000 oscilloscope, front view R&S®RTA4000 oscilloscope, front view R&S®RTA4000 oscilloscope, side view R&S®RTA4000 oscilloscope, hero view R&S®RTA4000 oscilloscope, application image

Key facts

  • Bandwidth: 200 MHz to 1 GHz
  • Sample rate: up to 5 Gsample/s
  • Memory depth: up to 1 Gsample
  • ADC resolution: 10-bit
  • Display: 10.1’’ capacitive touchscreen

See more of your signal with the power of 10

Designed with top class signal integrity and responsive ultra-deep memory, the R&S®RTA4000 brings the power of 10 to a new level. The Rohde & Schwarz designed 10-bit ADC plus best-in-class noise and memory depth for sharp waveforms, more accurate measurements and confidence when faced with unexpected measurement challenges.

Features & benefits

Signal analysis: quick results

See small signal details in the presence of large signals

The R&S®RTA4000 has a customized Rohde & Schwarz 10-bit A/D converter and is a four-fold improvement over conventional 8-bit A/D converters. The increased resolution results in sharper waveforms with more signal details that would otherwise be missed. One example is the characterization of switched-mode power supplies. The voltage across the switching device must be determined during the on/off times within the same acquisition.

10-bit A/D converter
Open Lightbox

10-bit A/D converter

10-bit A/D converter uncovers even small signal details and ensures vertical resolution four times higher than traditional oscilloscopes.

Segmented memory

100 Mpoint standard and 200 Mpoint interleaved

The R&S®RTA4000 has top-class memory depth of 100 Mpoints per channel and 200 Mpoint in interleaved mode. This is ten times more than similar oscilloscopes in the same instrument class. Users can capture longer acquisition sequences even at high sampling rates for more analysis results, such as when examining transients in switched-mode power supplies.

100 Msample standard memory
Open Lightbox

100 Msample standard memory

Capture and analyze pulsed and burst signals over a long period with up to 200 Mpoint standard acquisition memory

Capture more time at full bandwidth

Segmented memory: 1000 Mpoint with history function

The R&S®RTA-K15 option with deep, segmented memory analyzes signal sequences over a long observation period. Protocol-based signals with communications gaps such as I²C or SPI can be captured over several seconds or minutes. The variable segment sizes enable optimal utilization of the 1000 Mpoint memory. In history mode, previous acquisitions in the maximum segmented memory depth of 1000 Mpoint can be used for further analysis.

1000 Mpoint segmented memory
Open Lightbox

1000 Mpoint segmented memory

Capture the longest time periods with top-class 1000 Mpoint memory

Logic analysis with the MSO option

16 additional digital channels

The R&S®RTA-B1 option turns every R&S®RTA4000 into an intuitive MSO with 16 additional digital channels. The oscilloscope captures and analyzes signals from the analog and digital components of an embedded design - synchronized and time correlated to each other. The delay between A/D converter input and output can be conveniently determined with cursor measurements.

Four-bit DAC signal change.
Open Lightbox

Four-bit DAC signal change.

The R&S®RTA4000 captures and analyzes analog and digital signals that are synchronized and time-correlated with each other.

Waveform and pattern generator

Generate analog and digital stimuli

The R&S®RTA-B6 waveform and pattern generator for up to 50 Mbit/s can be used in educational settings and prototype hardware implementation. Apart from the common sine, square/pulse, ramp and noise waveforms, it outputs arbitrary waveforms and 4-bit signal patterns. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. Predefined patterns include. I2C, SPI, UART and CAN/LIN.

Waveform and pattern generator
Open Lightbox

Waveform and pattern generator

In addition to common sine, square/pulse, ramp and noise waveforms, it outputs user-defined waveforms and 4-bit signal patterns.

Digital voltmeter

Measure and display electrical potential

The R&S®RTA4000 features a 3-digit voltmeter (DVM) and 6-digit frequency counter on each channel for simultaneous measurements. Standard measurement functions include DC, AC+DC (RMS) and AC (RMS).

Digital voltmeter
Open Lightbox

Digital voltmeter

The 3-digit voltmeter measures and displays the electrical potential difference between two points in an electric circuit.

Frequency analysis mode

Difficult-to-find faults often result from the interaction between time and frequency signals. The R&S®RTA4000 FFT function is activated at the push of a button or by simply entering the center frequency and span. The high-performance FFT function in the R&S®RTA4000 oscilloscope can be used to analyze signals with up to 128k points. Other practical tools include cursor measurements and autoset in frequency domain.

FFT of a square wave
Open Lightbox

FFT of a square wave

The high-performance FFT functionality analyzes signals up to 128k points.

Mask test mode

Mask tests quickly reveal whether a specific signal lies within defined tolerance limits. Masks assess the quality and stability of a DUT based on statistical pass/fail evaluations. Signal anomalies and unexpected results are quickly identified. When the mask is violated, the measurement stops. Each violation generates a pulse output at the AUX-OUT connector on the R&S®RTA4000. This pulse output can be used to trigger actions in the measurement setup.

Mask test with result statistics
Open Lightbox

Mask test with result statistics

The pass/fail evaluation assesses DUT quality and stability.

The best choice for power

See power signal details with up to 10-bit resolution

Even the smallest details of a high dynamic signal are important to power measurements. RDS (on) verification for a MOSFET is one example. The high ADC resolution of R&S®RTA4000 oscilloscopes increases vertical resolution up to 10 bits. Previously unseen signal details are revealed and measurable. The RDS(on) example shows how the slope of the drain-to-source-voltage can be measured while the switch is closed.

Power analysis
Open Lightbox

Power analysis

Analyze input, output and transfer functions of switched-mode power supplies

Available models

Available models
Models
Bandwidth
Channels
Sample rate
Max. memory depth
Optional MSO
Starting at

R&S®RTA4004

Order number 1335.7700P04

Bandwidth
200 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Starting at
Price On Request

R&S®RTA4004 + RTA-B243

Order number 1335.7700P34

Bandwidth
350 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Starting at
Price On Request

R&S®RTA4004 + RTA-B245

Order number 1335.7700P54

Bandwidth
500 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Starting at
Price On Request

R&S®RTA4004 + RTA-B2410

Order number 1335.7700P64

Bandwidth
1 GHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
200 Mpts
Optional MSO
16 digital channels
Starting at
Price On Request
Specifications
Vertical system
Analog channels 4
Digital channels (opt.) 16
Bandwidth (-3 dB) R&S®RTA4004 (with R&S®RTA-B24x options) 200 MHz, 350 MHz, 500 MHz, 1 GHz
Rise time R&S®RTA4004 (with R&S®RTA-B24x options) 1.75 ns, 1 ns, 700 ps, 350 ps
Input impedance 50 Ω ± 1,5% (meas.), 1 MΩ ± 1 % (meas.) || 14 pF ± 1 pF (meas.)
Input sensitivity max. bandwidth in all range at 1 MΩ: 500 μV/div to 10 V/div
at 50 Ω: 500 μV/div to 1 V/div
ADC resolution 10 bit, up to 16 bit with high resolution decimation
DC gain accuracy offset and position = 0, maximum operating temperature change of ±5°C after self-alignment input sensitivity > 5 mV/div: ±1 % of full scale
input sensitivity ≤ 5 mV/div to ≥ 1 mV/div: ±1.5 % of full scale
input sensitivity < 1 mV/div: ±2.5 % of full scale
Acquisition system
Real-time sampling rate 2.5 Gsample/s; 5 Gsample/s, interleaved
Acquisition memory 100 Mpoint (200 Mpoint, interleaved);
1 Gsample segmented memory
Max. acquisition rate 64 000 waveforms/s
(2 000 000 in fast segmented memory mode)
Horizontal system
Timebase range selectable between 0.5 ns/div and 500 s/div
Accuracy (after delivery/calibration) ±0.5 ppm
Channel-to-channel skew < 200 ps (meas.)
Channel deskew ±500 ns
Trigger system
Standard trigger types edge, width, video (PAL, NTSC, SECAM, PAL-M, SDTV 576i, HDTV 720p, HDTV 1080i, HDTV 1080p), pattern, line, serial bus
Optional trigger types I2C, SPI, UART/RS-232/RS-422/RS-485, CAN/LIN, audio (I2S),ARINC 429, MIL-STD-1553
Trigger sensitivity with DC, AC, LF reject, noise reject 1 GHz, 500 MHz, 350 MHz > 2.2 mVpp input sensitivity + 1 div (nom.) (input sensitivity: [mV/div]) 200 MHz, 100 MHz > 1.5 mVpp input sensitivity + 0.8 div (nom.) (input sensitivity: [mV/div]) 20 MHz > 0.6 mVpp input sensitivity + 0.4 div (nom.) (input sensitivity: [mV/div]) with HF reject all input sensitivities 1 div (meas.)
Analysis and measurement functions
Automatic measurements 32
Cursor measurements 4
Waveform mathematics Five equations math-on-math functions (addition, subtraction, multiplication, division, square, square root, abs. value, reciprocal, inverse, common log,, natural log., derivative, integral, low pass, high pass, track unipolar + bipolar on period, frequency, pulse width, duty cycle)
Mask testing
Mask definition elementary (tolerance mask around the signal)
History and segmented memory
Number of segments up to 87 380
Protocol trigger and decode
Supported protocols I2C, SPI, UART/RS-232/RS-422/RS-485, CAN, LIN, I2S, MIL-STD-1553, ARINC429
Waveform generator
Resolution 14 bit
Sample rate 250 Mpoint/s
Amplitude high Z; 50 Ω 20 mV to 10 V (Vpp); 10 mV to 5 V (Vpp)
DC offset high Z; 50 Ω ±5 V; ±2.5 V
Arbitrary max. 10 Mpoint/s; 32k point
Logic analyzer (MSO) functionality
Digital input channels 16
MSO memory depth two logic probes: 100 Mpoint for every channel
one logic probe: 200 Mpoint for every channel
MSO Bandwidth 400 MHz (meas.)
MSO sampling rate 2.5 Gsample/s; 5 Gsample/s, interleaved
MSO input impedance 100 kΩ ± 2 % || ~4 pF (meas.) at probe tips
Parallel buses up to 4
General data
Dimensions W × H × D 390  mm × 220 mm × 152 mm
(15.4 in × 8.66 in × 5.98 in)
Weight 3.3 kg (7.3 lb)
Display 10.1" WXGA TFT color display (1280 × 800 pixel)
Interfaces USB host with MTP, USB device, LAN, powerful web server for remote display and operation
Operating system Embedded

Available options

General
Product
Description

Order number 1335.7823.02

Description

Mixed signal option: 400 MHz

Turns R&S®RTA4000 oscilloscopes into fast, precise and easy-to-use mixed signal oscilloscopes (MSO).

R&S®RTA-B6

Order number 1335.7830.02

Description

Arbitrary waveform generator

Adds a 25 MHz signal generator and a 4-bit pattern generator to your R&S®RTA4000 oscilloscopes.

Bandwidth upgrade
Product
Description
R&S®RTA-B243

Order number 1335.7846.02

Description

Bandwidth upgrade of the R&S®RTA4004 to 350 MHz bandwidth

R&S®RTA-B245

Order number 1335.7852.02

Description

Bandwidth upgrade of the R&S®RTA4004 to 500 MHz bandwidth

R&S®RTA-B2410

Order number 1335.7869.02

Description

Bandwidth upgrade of the R&S®RTA4004 to 1 GHz bandwidth

Serial triggering and decoding
Product
Description

Order number 1335.7681.02

Description

I²C/SPI serial triggering and decoding

Triggering and decoding of I²C and 2-wire, 3-wire or 4-wire SPI buses

Order number 1335.7698.02

Description

UART/RS-232/RS-422/RS-485 serial triggering and decoding

Triggering and decoding of UART based protocols and RS-232, RS-422 as well as RS-485 buses

Order number 1335.7717.02

Description

CAN/LIN serial triggering and decoding

Triggering and decoding of CAN and LIN interfaces

Order number 1335.7723.02

Description

I²S/LJ/RJ/TDM triggering and decoding

Triggering and decoding of I²S buses

Order number 1335.7730.02

Description

MIL-1553 serial triggering and decoding

Triggering and decoding of MIL-STD-1553 buses

Order number 1335.7746.02

Description

ARINC 429 serial triggering and decoding

Triggering and decoding of ARINC 429 buses

General analysis
Product
Description

Order number 1335.7769.02

Description

Power analysis

When analyzing power electronics, the input and output and the internal transfer function of the component have to be characterized. The power analysis option provides the necessary measurement functions, including inrush current, output spectrum and safe operating area (SOA).

Order number 1335.7975.02

Description

Frequency Response Analysis (Bode plot)

The R&S®RTA-K36 frequency response analysis (Bode plot) option lets you perform low-frequency response analysis on your oscilloscope easily and quickly. It characterizes the frequency response of a variety of electronic devices, including passive filters and amplifier circuits. For switch mode power supplies, it measures the control loop response and power supply rejection ratio.

Order number 1335.7981.02

Description

Spectrum analysis and spectrogram

The spectrum analysis option enhances the powerful FFT capability of R&S®RTA4000 oscilloscopes with spectrogram display.

General accessories
Product
Description
R&S®RTB-Z1

Order number 1333.1728.02

Description

Front cover

Protects the front of the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000

R&S®RTB-Z3

Order number 1333.1734.02

Description

Soft bag

Stores the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 oscilloscope and accessories

R&S®RTB-Z4

Order number 1335.9290.02

Description

Transit case with wheels for R&S®RTB

Order number 1335.7875.02

Description

Accessory case for probes and small parts for all Rohde and Schwarz oscilloscopes

R&S®RT-Z2T

Order number 1338.0007.02

Description

Probe adapter

Enables Tek’s TekProbe-BNC level 2 probes to connect to Rohde & Schwarz probe interface

R&S®ZZA-RTB2K

Order number 1333.1711.02

Description

19" rackmount adapter for R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 with 5HU

Passive probes
Product
Description

Order number 1333.2401.02

Description

Passive probe, 500 MHz, 10:1

Order number 1409.7550.00

Description

Passive probe, 500 MHz, 10:1

Order number 1333.1370.02

Description

Passive probe, 38 MHz, 1:1

Active single-ended probes
Product
Description

Order number 1333.0815.02

Description

Active single-ended probe, 1 GHz, BNC interface

Order number 1418.7007.02

Description

Active single-ended probe, 1 GHz, Rohde & Schwarz probe interface

Order number 1410.4080.02

Description

Active single-ended probe, 1 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Order number 1410.3502.02

Description

Active single-ended probe, 1.5 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Active differential probes
Product
Description

Order number 1410.4715.02

Description

Active differential probe, 1 GHz, Rohde & Schwarz probe interface

Order number 1410.4409.02

Description

Active differential probe, 1.5 GHz, Rohde & Schwarz probe interface

Power rail probes
Product
Description

Order number 1800.5006.02

Description

Power rail probe, 2 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

2.0 GHz, 1:1, 50 kΩ, R&S probe interface

High voltage probes
Product
Description

Order number 1333.0873.02

Description

250 MHz passive high voltage probe

Order number 1409.7720.02

Description

400 MHz passive high voltage probe

Order number 1409.7737.02

Description

400 MHz passive high voltage probe

Order number 1800.2307.02

Description

200 MHz High voltage differential probe

Order number 1800.2107.02

Description

100 MHz High voltage differential probe

Order number 1800.2207.02

Description

200 MHz High voltage differential probe

Order number 1800.2007.02

Description

100 MHz High voltage differential probe

Current probes
Product
Description

Order number 1333.0850.02

Description

AC/DC 20 kHz current probe

Order number 1333.0844.02

Description

100 kHz current probe

Order number 1409.8204.02

Description

2 MHZ current probe

Order number 1409.7750K02

Description

10 MHZ current probe

Order number 1409.8210.02

Description

10 MHZ Current probe

Order number 1409.8227.02

Description

50 MHZ Current probe

Order number 1409.7766K02

Description

100 MHZ current probe

Order number 1409.8233.02

Description

100 MHZ current probe

Order number 1409.7772K02

Description

120 MHz current probe

Order number 1801.4932.02

Description

120 MHz current probe

EMC near field probes
Product
Description

Order number 1147.2736.02

Description

E and H near-field probe set

Logic probes
Product
Description
R&S®RT-ZL04

Order number 1333.0721.02

Description

400 MHz logic probe

Probe accessories
Product
Description

Order number 1409.7789.02

Description

Power supply for probes

Power supply for R&S®RT-ZC10/20/30 probes, +/-12V DC, +/-2.5A

Order number 1410.4744.02

Description

External attenuator

10:1, 2.0 GHz, 1.3 pF, 60 V DC, 42 V AC (peak) for R&S®RT-ZD20/30 probes. Included in R&S®RT-ZD10.

Order number 1800.0004.02

Description

Power deskew fixture

Deskew fixture for voltage and current probes for power measurements; includes USB 2.0 cable for power supply

Order number 1326.3641.02

Description

3D probe positioner

3D positionier with central tensioning knob for easy clamping and positioning of probes (span width: 200 mm, clamping range: 15 mm)

Application bundles
Product
Description
R&S®RTA-PK1

Order number 1335.7775.02

Description

Application bundle (R&S®RTA-K1, -K2, -K3, -K5, -K6, -K7, -K31, -K36, -K37 and -B6)

Application bundle contains triggering and decoding I²C/SPI (R&S®RTA-K1), UART/RS-232/RS-422/RS-485 (R&S®RTA-K2) and CAN/LIN (R&S®RTA-K3), I²S (R&S®RTA-K5), MIL-1553 (R&S®RTA-K6), ARINC429 (R&S®RTA-K7), spectrum analysis and spectrogram (R&S®RTA-K37), power analysis (R&S®RTA-K31), frequency response analysis (R&S®RTA-K36), arbitrary generator (R&S®RTA-B6) for R&S®RTA4000 models

R&S®RTA-PK1US*

Order number 1335.7998.02

Description

Application bundle (R&S®RTA-K1, -K2, -K3, -K5, -K6, -K7, -K31, -K36, -K37 and -B6)

Application bundle contains triggering and decoding I²C/SPI (R&S®RTA-K1), UART/RS-232/RS-422/RS-485 (R&S®RTA-K2) and CAN/LIN (R&S®RTA-K3), I²S (R&S®RTA-K5), MIL-1553 (R&S®RTA-K6), ARINC429 (R&S®RTA-K7), power analysis (R&S®RTA-K31), frequency response analysis (R&S®RTA-K36), spectrum analysis and spectrogram (R&S®RTA-K37), arbitrary generator (R&S®RTA-B6) for R&S®RTA4000 models * ONLY distributed in North America

R&S®RTA4000 - Media center

R&S®RTA4000 - Media Center

View more

Oscilloscopes application videos - Media center

View more

Also interesting for you

10 years of Rohde & Schwarz oscilloscope innovation

More information

Oscilloscopes promotion

Choose the right R&S promotion for your individual needs and save your budget

More information

Oscilloscope webinar center for digital design and power electronics applications

More information

Solution for

Analog/digital design and test

Check out Rohde & Schwarz solutions for signal and power integrity, measurement of small signals and EMI debugging.

More information

Power electronics testing

Let our test und measurement solutions assist you to create low power consuming and reliable product.

More information

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.