Promo: What's next? Taking industry leadership or watching from the sidelines?

What's next? Taking industry leadership or watching from the sidelines?

Take the lead with up to 60% off our instruments

R&S®ZVAX-TRM extension unit

Configurable signal conditioning for measurements on active components

R&S®ZVAX-TRM extension unit
Open Lightbox
R&S®ZVAX-TRM extension unit
Open Lightbox
R&S®ZVAX-TRM extension unit
Open Lightbox
R&S®ZVAX-TRM extension unit
Open Lightbox
R&S®ZVAX-TRM extension unit
Open Lightbox
R&S®ZVAX-TRM extension unit, Front view R&S®ZVAX-TRM extension unit, Front view R&S®ZVAX-TRM extension unit, Side view R&S®ZVAX-TRM extension unit, Back view R&S®ZVAX-TRM extension unit, Side view

Key facts

  • Extension unit for the R&S®ZVA/ZVT network analyzer
  • For measurements of T/R modules, receivers, transceivers, power amplifiers
  • Base unit ready for high power measurements
  • R&S®ZVAX-TRM models up to 24/40/50/67 GHz
  • Flexible configuration for the required application
  • 3-year warranty extension

Extension unit for measurements on active components

Configurable signal conditioning for R&S®ZVA/ZVT

The configurable R&S®ZVAX‑TRM extension unit is used with an R&S®ZVA/R&S®ZVT network analyzer to provide signal conditioning for demanding measurements on active devices under test. For example, it allows measurements on pulsed signals or noise figure measurements on transmit/receive (T/R) modules. Together with an R&S®ZVA network analyzer, the R&S®ZVAX‑TRM provides customized test sets for applications up to 24/40/50/67 GHz (restrictions on some options for the 67 GHz model).

Features & benefits

Configurable test system

Flexible characterization of T/R modules

The R&S®ZVAX‑TRM is an extension unit for the R&S®ZVA/ZVT. The configurable external box adds hardware components required for transmit/receive modules or high-power testing. The base unit has two ports, couplers, and path access loops. Modules can be added as needed: output pre-amplifiers, combiners, pulse modulators, receiver pre-amplifiers. Uncoupling the options from the VNA protects it and maintains  full RF performance for the base unit when measuring without the R&S®ZVAX-TRM.

Convenient control via a graphical user interface
Open Lightbox

Convenient control via a graphical user interface

Excellent performance

Excellent performance data for measurements on T/R modules

The T/R module characteristics can be measured in both directions, making bidirectional pulse measurements possible. High output power levels are standard, even with a fully configured R&S®ZVAX-TRM.

Compact solution with open architecture

Signal access points to integrate external components and instruments

Measuring power or pulse profile calls for different test setups. To meet these requirements, the R&S®ZVAX-TRM offers the following:

  • Access to generator path (e.g. connect external power amplifiers)
  • Access to receiver path (e.g. connect attenuators for power measurements or to output signal to an external instrument)
  • Access to reverence signal (e.g. to utilize automatic level control)

Open Lightbox

Customized configuration

Get what you need

The R&S®ZVAX-TRM extension unit in its base configuration supports high-power two-port measurements up to +43 dBm (pulsed signals) and can easily loop in external components.
For greater flexibility the R&S®ZVAX-TRM functions can be expanded with diverse options such as:

  • pulse modulators
  • low-noise preamplifiers
  • output amplifiers
  • combiners

Open Lightbox

Available models

Available models
Models
Frequency range

R&S®ZVAX-TRM24

Order number 1322.6500.24

Frequency range
24 GHz

R&S®ZVAX-TRM40

Order number 1322.6500.40

Frequency range
40 GHz

R&S®ZVAX-TRM50

Order number 1322.6500.50

Frequency range
50 GHz

R&S®ZVAX-TRM67

Order number 1322.6500.67

Frequency range
67 GHz

Available options

R&S®ZVAX-TRM24 extension unit
Product
Description
R&S®ZVAX24B31

Order number 1322.7020.24

Description

Low-noise pre-amplifier for R&S®ZVAX-TRM24

10 MHz to 24 GHz, measurement path port 1

R&S®ZVAX24B32

Order number 1322.7036.24

Description

Low-noise pre-amplifier for R&S®ZVAX-TRM24

10 MHz to 24 GHz, measurement path port 2

R&S®ZVAX24B712

Order number 1322.6969.24

Description

Pulse modulators for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate pulsed signals at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX24B73

Order number 1322.6975.24

Description

Pulse modulators for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate pulsed signals at network analyzer port 3 or at the R&S®ZVAX‑TRM24 port 1 (B213 option active)

R&S®ZVAX24B112

Order number 1322.6981.24

Description

Output amplifiers for R&S®ZVAX-TRM24

10 MHz to 24 GHz, for increased output power at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX24B134

Order number 1322.6998.24

Description

Output amplifiers for R&S®ZVAX-TRM24

10 MHz to 24 GHz, for increased output power at network analyzer port 3 and port 4 or at R&S®ZVAX‑TRM24 port 1 and port 2 (B213/B224 option active)

R&S®ZVAX24B213

Order number 1322.7007.24

Description

Combiner for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 1 (SRC 1 + 3)

R&S®ZVAX24B224

Order number 1322.7013.24

Description

Combiner for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 2 (SRC 2 + 4)

R&S®ZVAX-TRM40 extension unit
Product
Description
R&S®ZVAX40B31

Order number 1322.7020.40

Description

Low-noise pre-amplifier for R&S®ZVAX-TRM40

10 MHz to 40 GHz, measurement path port 1

R&S®ZVAX40B32

Order number 1322.7036.40

Description

Low-noise pre-amplifier for R&S®ZVAX-TRM40

10 MHz to 40 GHz, measurement path port 2

R&S®ZVAX40B712

Order number 1322.6969.40

Description

Pulse modulators for R&S®ZVAX-TRM40

10 MHz to 40 GHz, to generate pulsed signals at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX40B73

Order number 1322.6975.40

Description

Pulse modulators for R&S®ZVAX-TRM40

10 MHz to 40 GHz, to generate pulsed signals at network analyzer port 3 or at R&S®ZVAX‑TRM24 port 1 (B213 option active)

R&S®ZVAX40B112

Order number 1322.6981.40

Description

Output amplifiers for R&S®ZVAX-TRM40

10 MHz to 40 GHz, for increased output power at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX40B134

Order number 1322.6998.40

Description

Output amplifiers for R&S®ZVAX-TRM40

10 MHz to 40 GHz, for increased output power at network analyzer port 3 and port 4 or at the R&S®ZVAX‑TRM24 port 1 and port 2 (B213/B224 option active)

R&S®ZVAX40B213

Order number 1322.7007.40

Description

Combiner for R&S®ZVAX-TRM40

10 MHz to 40 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 1 (SRC 1 + 3)

R&S®ZVAX40B224

Order number 1322.7013.40

Description

Combiner for R&S®ZVAX-TRM40

10 MHz to 40 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 2 (SRC 2 + 4)

R&S®ZVAX-TRM50 extension unit
Product
Description
R&S®ZVAX50B31

Order number 1322.7020.50

Description

Low-noise pre-amplifier for R&S®ZVAX-TRM50

10 MHz to 50 GHz, measurement path port 1

R&S®ZVAX50B32

Order number 1322.7036.50

Description

Low-noise pre-amplifier for R&S®ZVAX-TRM50

10 MHz to 50 GHz, measurement path port 2

R&S®ZVAX50B712

Order number 1322.6969.50

Description

Pulse modulators for R&S®ZVAX-TRM50

10 MHz to 50 GHz, to generate pulsed signals at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX50B73

Order number 1322.6975.50

Description

Pulse modulators for R&S®ZVAX-TRM50

10 MHz to 50 GHz, to generate pulsed signals at network analyzer port 3 or at R&S®ZVAX‑TRM24 port 1 (B213 option active)

R&S®ZVAX50B112

Order number 1322.6981.50

Description

Output amplifiers for R&S®ZVAX-TRM50

10 MHz to 50 GHz, for increased output power at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX50B134

Order number 1322.6998.50

Description

Output amplifiers for R&S®ZVAX-TRM50

10 MHz to 50 GHz, for increased output power at network analyzer port 3 and port 4 or at the R&S®ZVAX‑TRM24 port 1 and port 2 (B213/B224 option active)

R&S®ZVAX50B213

Order number 1322.7007.50

Description

Combiner for R&S®ZVAX-TRM50

10 MHz to 50 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 1 (SRC 1 + 3)

R&S®ZVAX50B224

Order number 1322.7013.50

Description

Combiner for R&S®ZVAX-TRM50

10 MHz to 50 GHz, to generate two-tone signal at R&S®ZVAX‑TRM port 2 (SRC 2 + 4)

R&S®ZVAX-TRM67 extension unit
Product
Description
R&S®ZVAX67B31

Order number 1322.7020.67

Description

Low-noise pre-amplifier for R&S®ZVAX-TRM67

10 MHz to 67 GHz, measurement path port 1

R&S®ZVAX67B32

Order number 1322.7036.67

Description

Low-noise pre-amplifier for R&S®ZVAX-TRM67

10 MHz to 67 GHz, measurement path port 2

R&S®ZVAX67B712

Order number 1322.6969.67

Description

Pulse modulators for R&S®ZVAX-TRM67

10 MHz to 67 GHz, to generate pulsed signals at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX67B73

Order number 1322.6975.67

Description

Pulse modulators for R&S®ZVAX-TRM67

10 MHz to 67 GHz, to generate pulsed signals at network analyzer port 3 or at the R&S®ZVAX‑TRM24 port 1 (B213 option active)

R&S®ZVAX67B112

Order number 1322.6981.67

Description

Output amplifiers for R&S®ZVAX-TRM67

10 MHz to 67 GHz, for increased output power at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX67B134

Order number 1322.6998.67

Description

Output amplifiers for R&S®ZVAX-TRM67

10 MHz to 67 GHz, for increased output power at network analyzer port 3 and port 4 or at the R&S®ZVAX‑TRM24 port 1 and port 2 (B213/B224 option active)

R&S®ZVAX67B213

Order number 1322.7007.67

Description

Combiner for R&S®ZVAX-TRM67

10 MHz to 67 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 1 (SRC 1 + 3)

R&S®ZVAX67B224

Order number 1322.7013.67

Description

Combiner for R&S®ZVAX-TRM67

10 MHz to 67 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 2 (SRC 2 + 4)

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.