79 Results
How to bisect the result in dB with Trace Mathematics
Recall of user's own calibration kits and connectors via remote
Calibration of two channels simultaneously with remote commands
4 Port Calibration with a 2 Port automatic calibration kit possible?
Is there a way to query the data of all traces at once?
Calculate the mixed-mode S-parameter from an S4P file
TRL calibration - middle of line or end of line
What is the function of "Resolve pool link" in the calibration manager?
Loading an S-parameter file from a PC into a memory trace
Most accurate way to measure the length of a cable with a VNA
Reading the magnitude (dB) and phase (degrees) values directly
How can I change the display resolution when I use an external monitor?
Which settings should I use for the Transform Time Domain mode?
Cannot use internal display and external monitor together at the same time.
VNA - do I really need a sliding match for calibration?
Changing the update display rate of a sweep with many sweep points.
Calibrating a vector network analyzer (VNA) with different connectors on each port
Converting the real and imaginary numbers to magnitude in dB and phase in degrees.
Sending a remote Control Command internally
What is the correct pin layout of the DC inputs on the network analyzer's rear panel?
I have set my VNA to single sweep mode and switched on averaging with a factor of 10. But when I restart the single sweep, it stops after 1 sweep and the averaging is not done.
I trigger this single sweep with the RSZVB_Send_Trigger_and_Wait_for_OPC driver, but this driver does not wait for the complete 10 sweeps. If I don't use averaging, this program is works.
I query the values of a trace using scpi commands. But I get the y-values only. Is there a possibility to get the y-values also (frequency)?
How can I switch from remote to local state via remote control?
I have used my TRL calibration kit with my ZVA before. Now I want to use also with my ZNB. But when I try to load the data of the calibration kit into the ZNB, the above error message is shown.
How do I calculate these frequency points when I have a logarithmic sweep and know the center frequency, the span and the number of sweep points?
I want to use Port 1 and Port 3, so I tried to switch them on by setting the value to 1 (the default value) and to switch off Port 2 and Port 4 by setting the value to 0. But this does not work. How do I set the ports?
R&S®ZVA-Zxx Millimeterwave Converters - Specifications
R&S ZV-WRxx R&S®ZCWM-570 Waveguide Calibration Kits - Specifications