Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
1106 Results
This application note provides information about measurements on pulsed signals with a spectrum analyzer. Examples show the practical realisation of measurements like pulse width, peak power and mean power, and the limitations of spectrum analyzer measurements. A method for long time average power measurement is explained.
16-Jan-2003 | AN-No. 1EF48
This application note offers a straightforward description of how to analyze EMI problems using the Rohde & Schwarz Oscilloscopes. The discussion begins by covering the basic mechanisms that can result in unwanted RF emissions and then describes how to proceed in analyzing EMI problems. Finally, a practical example is given to illustrate the analysis process.
25-Jun-2014 | AN-No. 1TD05
The simulation of impulsive noise for tests on set-top boxes for digital TV (DTV) has so far been a highly complex task regarding the reproducibility of test signals. Using state-of-the-art technology from Rohde & Schwarz, this task can be accomplished with a simple test setup
07-Jul-2003 | AN-No. 7BM45
A key challenge for embedded devices with DDR memories is to maintain signal integrity in the presence of power and ground rail fluctuations. This becomes even more important as supply voltages decrease and switching speed increases leading to tighter power rail tolerances and jitter requirements.
05-Apr-2017
Overview of the choices for downloading waveform data for remote processing
15-Feb-2018
With continuously increasing data rates, signal integrity in high speed digital designs becomes more and more demanding
08-Jul-2022
The purpose of the test setup described is to ensure or to enhance the level accuracy of signal generators or the generator part of communication testers. The level accuracy of test signals is particularly important at low levels when measuring BER level sensitivity at digital communication receivers. The highly linear FSP spectrum analyzer is used in combination with a power meter to get the best possible accuracy with high measurement speed over a very wide level range.
18-Feb-2011 | AN-No. 1MA21
RTC, RTC1000, Application Card, Determining current-voltage characteristics with the oscilloscope With their included component tester, the R&S®RTC1000 oscilloscopes are universally deployable in development and educational environments. Determining current-voltage characteristics with the oscilloscope RTC, RTC1000, Application Card, Determining current-voltage characteristics with the oscilloscope
20-Dec-2017
The sweep tool has several R&S®NGU source measure unit functions for characterizing semiconductors.
02-May-2023
Rohde & Schwarz has made a breakthrough for better jitter and noise separation with the launch of SW options (RT-K133 & RT-K134). Technical information on this new algorithm were presented at . We received a lot of positive feedback on this new technique. However, one fundamental question still remained. How does this new algorithm compare to established solutions available on the market today?This app note provides an introduction into the various jitter components and elucidates the commonly available jitter separation frameworks. Finally, it provides a comparison between the different commercial solutions, while explaining the used waveforms and signals to achieve the results. Curios? Read on, to learn how Rohde & Schwarz’s new option for jitter and noise separation delivers dependable and stable results. If you are interested in evaluating on your own, you may download the waveform files with registration.
08-Dec-2021 | AN-No. 1SL375
This application note reviews a new calibration subsystem which consists of Inline Calibration Units (ICUs). These ICUs are designed for in situ use, so they are left in place both during the calibration procedure and during the measurement of the Device Under Test (DUT).This adds versatility, convenience and accuracy to the VNA based measurement system, as it means the calibration can be refreshed at any time without manually disconnecting the DUT from the test system.
29-Sep-2017 | AN-No. 1EZ71
This application note shows how to remote control the switching of RF and digital I/O signals by R&S®OSP Open Switch and Control Platform directly from a Vector Network Analyzer (VNA) or from a Spectrum Analyzer (SA). The R&S®ZVA, R&S®ZVB, R&S®ZNB, R&S®FSW and R&S®FSV families are covered. The application note first describes the requirements and setup procedure. It is shown how to install the software and how to set up the system in order to get highest flexibility and best usability. It is then shown how to calibrate the entire configuration and finally some practical examples are provided. Switching is explained using VNAs as an example, the appendix 5.4 provides hints regarding the differences when using SAs in a similar way.
06-Dec-2013 | AN-No. 1MA226
Signal monitoring has proven an effective technique when it comes to identifying and correcting quality problems in transmitted TV broadcast signals during broadcast operation. For a DVB‑T2 signal using multiple physical layer pipes (multi-PLP), a separate receiver is required to analyze each PLP. The R&S®DVMS digital TV monitoring systems are extremely flexible and can be configured to meet customer's needs – from sequential PLP monitoring systems with a single receiver to systems providing seamless, parallel multi-PLP analysis.
24-Jul-2012
The aim of this application note is to provide information regarding Rohde & Schwarz instrument drivers. This paper shall help application engineers and software developers to easily get an understanding of advanced techniques to develop test and measurement (T&M) applications by utilizing Rohde & Schwarz instrument drivers. Furthermore the nomenclature used for Rohde & Schwarz instrument drivers will be explained.
01-Jan-2013 | AN-No. 1MA153
This application note discusses the use of the WOOSHCOM® DHEI output interface adapter (model 3010), which converts the transport stream from DHEI format into DVB-ASI. Further processing and analysis of the transport stream signal then becomes available with any of the Rohde & Schwarz Test & Measurement instruments. It also describes how to extract an unencrypted transport streams out of a Motorola IRT.
08-Jun-2004 | AN-No. 7BM40
The R&S®SMBV100A vector signal generator offers a remote emulation feature that makes it possible to control the instrument by commands other than the built-in native SCPI commands. This feature allows the user to replace signal generators, e.g. from other manufacturers, with the R&S®SMBV100A without having to change the remote control code. This application note describes how to use the remote emulation feature in general. Furthermore, it describes in detail the remote emulation for each supported instrument, limitations of the individual emulations and the remaining differences between the emulated and the original commands.
11-Oct-2016 | AN-No. 1GP91
Simultaneous DL throughput verification and UL transmission testing with the R&S®CMW500
29-Jul-2009
Test time is a critical parameter when it comes to evaluating the cost of test.This application note describes typical spectrum analyzer measurements in production environments and discusses different approaches to speed them up.
17-Nov-2014 | AN-No. 1EF90
This application note describes the software configuration, system calibration and test routine for EMC measurements according to the EMS standard IEC / EN 61000-4-6.
29-Mar-2007 | AN-No. 1SP33
TDMA communications systems like GSM, DCS 1800 or PCS 1900 make effective use of the frequency spectrum by assigning several subscribers to the same frequency channel. Each subscriber has access to one predefined time slot for transmitting information. With GSM eight subscribers share one frequency channel with a bandwidth of 200 kHz. In order not to disturb the other users of the 200-kHz channel it has to be ensured that, for instance, a mobile sends in the assigned time slot only and that no power is emitted by the transmitter at other times. For this reason the transmitter power is practically switched off in the transmission intervals.
16-Jan-2002 | AN-No. 1EF18
In accelerator physics, pulsed signals frequently need to be measured. The digital trigger and low noise frontend of the R&S®RTO/RTP digital oscilloscope make it possible to perform the high precision measurements needed to characterize the experimental setup. Several measurement functions specially developed for accelerator physics labs support detailed signal analysis.
17-Dec-2013
This Application Note provides a step-by-step description of all video decoding settings you need to make. It also contains valuable information about how to optimize replay for various applications.
02-Mar-2006 | AN-No. 7BM52
Test Solutions Based on R&S®CMX500 Platform
The evolution of mobile communication enters 5G New Radio (NR) era with pivotal features. Voice call service is however still considered as an indispensable element for mobile devices and worldwide network operators continue to maintain the voice service for their subscribers. In comparison to other Over-the-Top (OTT) voice services, such as WhatsApp©, Teams© etc., Voice over NR (VoNR) and Voice over LTE (VoLTE) maintain QoS, support well established handover mechanism and emergency call, and do not require to pre-install OTT app on the phone.In order to provide premium voice service and enhance the superb user experience, audio tests on mobile devices are essential before the product launch. Different audio test aspects among which acoustic, functional, performance and field tests need to be considered.This application note describes the performance test with focus on VoNR audio quality measurement via electrical interface of the mobile device. The test solution is based on R&S®CMX500 with its integrated POLQA algorithm.
26-Jul-2023 | AN-No. 1SL401
The following application note describes the function and operation of user menus for FSE Spectrum Analyzers including option Vector Signal Analysis (FSE-B7). For measurements according to the PCS 1900 standard user menus are provided, which perform settings on FSE for Base Station testing required in the standard. The menu and the accompanying setups are stored on a floppy disk. For operation of the menus firmware version 1.40 or higher is required. Option Vector Signal Analysis FSE-B7 has to be installed for the use of the application menu.
17-Jan-2002 | AN-No. 1EF24
This application note provides a brief introduction into the capabilities of the Rohde & Schwarz Vector Signal Generators (VSG) to create user defined digitally modulated signals called Custom Digital Modulation (CDM). Additionally an in depth description of the functions and the operation of the CDM-Toolbox is provided. The CDM-Toolbox is application software which allows an easy remote configuration of CDM signals on Rohde & Schwarz VSGs but also the creation of data list and control list files which are most useful to further extend the application area of CDM signals.
24-Jul-2017 | AN-No. 1GP96
Need: easy exchange of multiple versions of content as one package in a digital formatSolution: interoperable master format (IMF) and R&S®CLIPSTER
26-Sep-2018
A special requirement for testing GSM components is to measure the electrical characteristics, such as the gain of a power amplifier, of the DUT under pulsed conditions. The test should be similar to real operating conditions for a mobile telephone.
28-Jul-1998 | AN-No. 1EZ42
Measuring the spurious emissions of transmitters used in GSM, DCS 1800 and PCS 1900 networks requires highly complex test setups since con-ventional spectrum analyzers do not have the necessary dynamic range. To obtain this range, notch filters are used to suppress the useful sig-nal. The spectrum analyzers of the FSE family make it possible for the first time to verify com-pliance with stipulated limit values for spurious emissions within the transmission band and out-side the reception band without the use of notch filters. The measurement problem and its solution by means of FSE are described in the following by way of the example of a GSM base station.
16-Jan-2002 | AN-No. 1EF17
Your measurement task: To analyze an RF module via its digital interface. This Application Note explains how. As interfaces between the baseband and the RF modules of mobile radio base stations and terminals are increasingly digital, instruments for testing such modules need digital baseband interfaces as well. The R&S®EX-IQ-Box is a digital interface adapter that provides digital baseband I/O for Rohde & Schwarz signal generators and signal analyzers. An R&S signal analyzer with digital baseband interface R&S®FSQ-B17 can analyze digital baseband components input from the R&S®EX-IQ-Box. Data collected with a test-setup consisting of an R&S signal analyzer and the digital interface adapter R&S®EX-IQ-Box can be used in an Agilent ADS environment. For details of how to input the results to ADS, see Application Note 1MA72: 'Using R&S® Instruments within Agilent®ADS®Software'
26-Jun-2009 | AN-No. 1MA147
With the R&S®RTB2000/RTM3000/RTA4000 oscilloscopes, you control and interact remotely via LAN. These oscilloscopes incorporate the USB-based connectivity standard media transfer protocol (MTP).
20-Mar-2017