R&S®AU600 Antenna

Active Omnidirectional Receiving Antenna System

  • Overview

Key facts

The Active Omnidirectional Receiving Antenna System is optimized for the reception of linearly polarized signals in the frequency range 20 MHz to 8 GHz

Features

  • Wide frequency range
  • Omnidirectional reception
  • Horizontal and vertical polarization simultaneously

Specifications

Model Frequency range
R&S®AU600 20 MHz to 8 GHz

Key facts

20 MHz to 8 GHz

The Active Omnidirectional Receiving Antenna System is optimized for the reception of linearly polarized signals in the frequency range 20 MHz to 8 GHz

Featuring a wide frequency range and omnidirectional reception of signals with vertical and horizontal polarization simultaneously, it is particularly suited for radiomonitoring and radiolocation Tasks in stationary or semi-mobile installations

The antenna system is designed for extreme environmental conditions and in a compact size which makes it ideal for locations with reduced available space.

Built-in switchable low noise amplifiers (LNA) and band-stop filters on the integrated switch board ensure maximum sensitivity and allow the installation even at locations in close vicinity to transmitting antennas.

features & benefits

  • Wide frequency range
  • Omnidirectional reception
  • Horizontal and vertical polarization simultaneously
  • Designed for extreme environmental conditions
  • Built-in switchable low noise amplifiers and band-stop filters
  • Suitable for Installation even at locations in close vicinity to transmitting antennas

Specifications

R&S®AU600
 
Frequency range 20 MHz to 8 GHz
Polarization linear vertical and horizontal
Input impedance 50 Ω
VSWR < 2.5 (typ 1.5)
Horizontal radiation pattern omnidirectional
Circularity of azimuth pattern
 Vertical polarization +/- 2.5 dB (typ.)
 Horizontal polarization +/- 4.5 dB (typ.)
Polarization decoupling 17 dB (typ.)
Third order intercept Point (IP3)
 Vertical, f < 0.85 GHz (active) 23 dBm (typ.)
 Vertical, f > 0.85 GHz (LNA enabled) 22 dBm (typ.)
 Horizontal, f < 0.85 GHz (active) 20 dBm (typ.)
 Horizontal, f > 0.85 GHz (LNA enabled) 23 dBm (typ.)
Second order intercept Point (IP2)
 Vertical, f < 0.85 GHz (active) 44 dBm (typ.)
 Vertical, f > 0.85 GHz (LNA enabled) 32 dBm (typ.)
 Horizontal, f < 0.85 GHz (active) 37 dBm (typ.)
 Horizontal, f > 0.85 GHz (LNA enabled) 33 dBm (typ.)
Destructive field-strength > 50 V/m
Stop band attenuation of internal filters
 GSM 1800/UMTS filter 25 dB (typ.)
 WLAN/LTE Band 7 filter 20 db (typ.)
DC power supply
via R&S®OSP-B158, nominal voltages (max current) -12V (90mA), +10V (285mA), +12V (550mA)
MTBF > 150 000 h
Operating temperature range –40 °C to +65 °C
Max. wind speed
 without ice accretion 275 km/h
 with 30mm ice accretion 200 km/h
Protection class IP X5 (in line with DIN EN 60529)
Dimensions (diameter x height) approx. 382 mm × 1015 mm
Weight approx. 17.5 kg
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Get a Demo

Please enter your inquiry.
Please enter your first name.
Please enter your name.
Please enter a valid email address.
Please enter your company name.
Please enter your city name.
Please enter your postal code.

Please enter your location.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

Please enter the characters shown in the image
show captcha
The input was not correct.
Do not enter data in this field
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Get a Quote

Please enter your inquiry.
Please enter your first name.
Please enter your name.
Please enter a valid email address.
Please enter your company name.
Please enter your city name.
Please enter your postal code.
Please enter your phone number.

Please enter your location.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

Please enter the characters shown in the image
show captcha
The input was not correct.
Do not enter data in this field
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Request information

Please enter your inquiry.
Please enter your first name.
Please enter your name.
Please enter a valid email address.
Please enter your company name.
Please enter your city name.
Please enter your postal code.

Please enter your location.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

Please enter the characters shown in the image
show captcha
The input was not correct.
Do not enter data in this field
International Website