- Bandwidth: 600 MHz to 6 GHz
- Max. sample rate: 20 Gsample/s
- Max. memory depth: 2 Gsample
- Up to 16-bit vertical resolution
- MSO: 16 digital channels, optional, retrofittable
Starting at 13.500 EUR
Key facts
Starting at 13.500 EUR
Engineered for multi-domain challenges
Offering bandwidths from 600 MHz to 6 GHz, RTO®2000 Series oscilloscopes excel at both time domain and frequency domain testing needs. With excellent signal fidelity, responsiveness of 1M waveforms/sec, and up to 16-bit vertical resolution, quickly measure with confidence. The capacitive touchscreen with SmartGrid makes for easy and intuitive use.
I Quickly find signal faults with 1 million waveforms/s
I 2 Gsample deep memory to analyze long sequences
I Up to 16-bit vertical resolution
I Multi-channel spectrum analysis
Order number 1329.7002.02
Order number 1329.7002.04
Order number 1329.7002.12
Order number 1329.7002.14
Order number 1329.7002.22
Order number 1329.7002.24
Order number 1329.7002.32
Order number 1329.7002.34
Order number 1329.7002.44
Order number 1329.7002.64
Vertical system | ||
Numbers of channels | R&S®RTO2002/R&S®RTO2012 R&S®RTO2022/R&S®RTO2032 |
2 |
R&S®RTO2004/R&S®RTO2014 R&S®RTO2024/R&S®RTO2034 R&S®RTO2044/R&S®RTO2064 |
4 | |
Analog bandwidth (–3 dB) and rise time at 50 Ω | R&S®RTO2002 and R&S®RTO2004 | 600 MHz, 583 ps |
R&S®RTO2012 and R&S®RTO2014 | 1 GHz, 350 ps | |
R&S®RTO2022 and R&S®RTO2024 | 2 GHz, 175 ps | |
R&S®RTO2032 and R&S®RTO2034 | 3 GHz, 116 ps | |
R&S®RTO2044 | 4 GHz, 100 ps | |
R&S®RTO2064 | on 4 channels: 4 GHz, 100 ps on 2 channels: 6 GHz, 76 ps |
|
All instruments can be extended to up to 6 GHz bandwidth. | ||
Impedance | 50 Ω ±1.5 % 1 MΩ ±1 % at 15 pF (meas.) |
|
Input sensitivity | max. bandwidth in all ranges | 50 Ω: 1 mV/div to 1 V/div, 500 μV to 1 V (optional); 1 MΩ: 1 mV/div to 10 V/div, 500 μV to 10 V (optional) |
ENOB of A/D converter | full-scale sine wave, < –3 dB frequency bandwidth | > 7 bit (meas.) |
Acquisition system | ||
Realtime sampling rate | R&S®RTO200x/201x/202x/203x | max 10 Gsample/s on each channel |
R&S®RTO2044/2064 | max. 10 Gsample/s on 4 channels max. 20 Gsample/s on 2 channels |
|
Acquisition memory | standard configuration, per channel/1 channel active | R&S®RTO2000: 2-channel-model: 50 /100 Msample R&S®RTO2000: 4-channel-model 50 /200 Msample |
max. upgrade (R&S®RTO-B110 option), per channel/1 channel active |
R&S®RTO2000: 2-channel-model: 1/2 Gsample R&S®RTO2000: 4-channel-model: 1/2 Gsample |
|
Max. acquisition rate | continuous aquisition and display, 10 Gsample/s, 1 ksample |
1 000 000 waveforms/s |
ultra-segmented-mode | < 300 ns blind time | |
Decimation modes | any combination of decimation mode and waveform arithmetics on up to 3 waveforms per channel | sample, peak detect, high resolution, root mean square |
Waveform arithmetics | off, envelope, average | |
Interpolation modes | linear, sin(x)/x, sample&hold | |
Horizontal system | ||
Timebase range | 25 ps/div to 10,000 s/div | |
Accuracy | after delivery/calibration R&S®RTO-B4 option |
±5 ppm ±0.02 ppm |
Trigger system | ||
Trigger types | edge, glitch, width, runt, window, timeout, interval, slew rate, data2clock, pattern, state, serial pattern, TV/video, serial bus trigger (optional), zone trigger (optional) | |
Zone trigger (opt.) | logical combination of max. 8 polygons, intersect or not intersect source: measurement channels, spectrum, math functions | |
Sensitivity | definition of trigger hysteresis | automatic or manually adjustable from 0 div to 5 div |
General data | ||
Dimensions | W x H x D | 427 mm x 249 mm x 204 mm (16.81 in x 9.8 in x 8.03 in) |
Weight | 9.6 kg (21.2 lbs) | |
Screen | 12.1" LC TFT capacitive color touchscreen, 1280 x 800 pixels (XGA) |
|
Interfaces | 1 Gbps LAN, type A: 2 x USB 3.1, 2 x USB 2.0, type B: 1 x USB 3.1, GPIB (optional), DVI and display port for external monitor, external trigger, trigger output |
No compromises and excellent quality - made by Rohde & Schwarz
10 years ago we expanded our measurement technology portfolio with the launch of R&S®RTO1000 and R&S®RTM1000. 10 years later, two product families have become eight: from entry-level and handheld to high-end instruments. Before we started, our engineers have taken a very close look at what doesn't fit on the instruments that are already on the market - and have made it better.Celebrate with us our 10th birthday and take part in our contest.
Oscilloscopes that fit your requirements and your budget
Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.
Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes
1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).
2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.
3. Participation is free of charge and not dependent on the purchase of goods or services.
4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.
5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:
Prize: 1x R&S®RTB2000 Digital Oscilloscope
6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.
7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.
8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.
9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.
10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.
11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.
12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.
13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.