FAQs from Rohde & Schwarz

RTM/RTA - Edge A/B Trigger - Remote commands for the trigger level

Question:

I am using the trigger type "EDGE A/B".

How can I set the levels for the A and for the B trigger with remote commands?

The command " TRIG:A:LEV ..xx" does not work for that trigger type.

Answer:

Here are the commands to set the levels:

TRIG:A:LEV:RIS:LOW 4.2500E-01 --> level for A Trigger (set to 425 mV )

TRIG:A:LEV2:RIS:LOW 2.00000E-01-->level for B Trigger (set to 200 mV )