Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
735 Results
DECT standard ETS 300 175-2 prescribes among others measurement of the transmit power and the unwanted power in adjacent channels. Following a brief introduction into DECT, this Application Note describes the standard-conforming measurement of the normal transmit power NTP and the unwanted adjacent-channel power ACP using a spectrum analyzer from the FSE family ( firmware version 1.63 and higher). Option FSE-B7 (Vector Signal Analyzer) is required for measuring the normal transmit power NTP since the signal must be demodulated for this measurement. Due to the wide dynamic range of FSEA20 and FSEA30, the adjacent channel power ACP can be measured without bandpass filters suppressing the transmit channel. Option FSE-B7 is not required for measuring the adjacent-channel power.
28-Apr-1998 | AN-No. 1EF42
Leaving aside the microwave generators, the present line of Rohde & Schwarz products comprisessignal generators up to 1 GHz (SMX, SMG), up to 2 GHz (SMH, SMGU), up to 3 GHz (SME, SMT) and up to 4.3 GHz (SMHU). For applications at higher frequencies, all signal generators can also be operated with an external passive frequency doubler. This extends the range of possible applications up to 8.6 GHz. Some degraded specs regarding level and modulation are described below. For people using the frequency range 3 to 6 GHz, the low priced combination SMT plus frequency doubler will mainly be interesting. Signal generator SMHU is useful for the frequency range up to 8.6 GHz. Especially the phase noise performance is excellent with this instrument. the required output signal. It should also be pointed out that the residual FM and the SSB phase noise will be 6 dB poorer as a result of frequency doubling.
20-Apr-1998 | AN-No. 1GPAN03
In contrast to standardized digital interfaces which are customary for communication between audio devices, diverse data formats are used between the internal modules of a particular device. The I²S interface developed by Philips has now been widely adopted for the latter. The data structure of this digital audio interface and the adaptation of Audio Analyzer UPD in the different operating modes of the I²S bus are described in this Application Note.
03-Apr-1998 | AN-No. 1GA25
Use of FSE Spectrum Analyzer for adjacent channel power measurements with wideband CDMA signals is explained. Optimum operation is shown by explanation the signal behavior and the internal structure of the FSE. The spectrum analyzer family FSE, featuring a very high dynamic range is an outstanding equipment for this purpose. Up to 73 dB dynamic range are attained.
17-Mar-1998 | AN-No. 1EF40
Signal Generator SMIQ has versatile analog and digital internal modulation capabilities. Optional Fading Simulator SMIQ-B14 adds a variety of fading functions to the integrated digital modulation capabilities of SMIQ at a highly attractive price as compared with similar products. This application note describes how to apply fading to signals of any source and with any type of modulation (analog and digital) in a very convenient way.
09-Mar-1998 | AN-No. 1MA07
To analyse the quality of tuners, lots of measurements have to be done. This application note presents a program, which combines these measurements to an automatically running sequence and gives a printout of the results. In addition, it explains the measurements and informs about the different standards.
16-Feb-1998 | AN-No. 1GA24
To analyse the quality of CD players, lots of measurements have to be done. This application note presents a program, which combines these measurements to an automatically running sequence and gives a printout of the results. A test CD is used for generating the test signals. Here the Audio Test Disc UPA-CD from Rohde & Schwarz is used, which holds all required signals in a sequence permitting automatic measurements to be carried out, without the need of controlling the CD player. In addition, this application note explains the measurements and informs about the different standards.
16-Feb-1998 | AN-No. 1GA21
Level or power measurement of especially modulated signals using spectrum analyzers is becoming more and more important . Whereas the first choice in terms of accuracy for power measurement of any carrier (modulated or non-modulated) is a power meter, power measurement of spurious or in the adjacent channel of a transmission system needs a selective power meter with high dynamic range. A power meter, however, is a non-selective device with limited dynamic range and is not appropriate for these types of measurements. The first choice is a spectrum analyzer because of its versatile use as a general-purpose instrument. Compared to a power meter its power measurement accuracy is worse. In general this can be overcome by substitution methods using a power meter, an attenuator and a signal generator. But substitution is time-consuming and requires more investment in test equipment than a single instrument. Therefore it is most important to have a spectrum analyzer like the FSE, which can fulfill at least most of the requirements in terms of measurement accuracy.
13-Jan-1998 | AN-No. 1EF36
GSM standard 11.10 prescribes a number of tests requiring measurements on mobile stations under multichannel conditions (fading). The combination of Radiocommunication Tester CRTP02 or CRTC02 and Signal Generator SMIQ allows cost-effective performance of the most important fading tests, in particular the tests according to sections 13.2, 14.2 and 14.3 of GSM 11.10. The aim of this application note is to familiarize the user with all the capabilities offered by the above combination of measuring instruments. The user should then be able to quickly generate and run his own fading tests using the IEC/IEEE-bus control commands described in this application note. To facilitate reading of the following, the testers CRTP02 and CRTC02 are referred to as CRTx.
07-Nov-1997 | AN-No. 1MA02
Today, digital audio signals are transmitted via standardized interfaces not only in the form of continuous data streams but also increasingly as burst audio signals. This application note shows various ways of generating and analyzing such data bursts with Audio Analyzer UPD. In the applications described, the parameters word clock, bit clock and word length can be set over wide ranges. Single-channel and dual-channel audio data with bit clocks far into the MHz range can be processed.
05-Nov-1997 | AN-No. 1GA38
- not available -
01-Aug-1997 | AN-No. 7BM39
The following application note describes the function and operation of user menus for FSE Spectrum Analyzers including option Vector Signal Analysis (FSE-B7). For measurements according to the PCS 1900 standard for Mobile Stations user menus are provided, which perform settings on FSE for the different measurements required in the standard. The menu and the accompanying setups are stored on a floppy disk.
01-Nov-1996 | AN-No. 1EF22
The following paragraphs are intended to show the capabilities of the Rohde&Schwarz Signal Generator SMT performing VOR air navigation receiver tests. The procedures presented should not be considered binding or mandatory. It is expected that the user once familiar with the use of SMT for VOR/ILS receiver tests will design and implement procedures which satisfy equipment and regulatory requirements.
06-Jul-1994 | AN-No. 1GPAN10
The following paragraphs are intended to show the capabilities of the Rohde & Schwarz Signal Generator SMT performing ILS and Marker Beacon receiver tests. The procedures presented should not be considered binding or mandatory. It is expected that the user once familiar with the use of SMT for VOR/ILS receiver tests will design and implement procedures which satisfy equipment and regulatory requirements.
06-Jul-1994 | AN-No. 1GPAN11