R&S®HK116E Antenna

Biconical Antenna

  • Overview

Key Facts

The R&S®HK116E is a biconical dipole antenna for linearly polarized waves.

The antenna features a wide frequency range, a radiation pattern virtually independent of frequency plus low weight.

Features

  • Low frequency dependence of the radiation patterns
  • Very low cross polarization permits accurate spatial determination of the electrical field vector
  • Compliant with requirements for balun imbalance and cross-polar performance given in CISPR 16-1-4 Ed. 3.0 (sec. 4.5.4, 4.5.5)

Specifications

Model Frequency range
R&S®HK116E 20 MHz to 300 MHz

Key Facts

  • 20 MHz to 300 MHz
  • For radiated emission measurements

    The R&S®HK116E is a biconical dipole antenna for linearly polarized waves.

    The antenna features a wide frequency range, a radiation pattern virtually independent of frequency plus low weight.

    The R&S®HK116E is individually calibrated in line with ANSI C63.5 and ARP 958 and particularly suitable for radiated emission measurements in EMC test rooms.

    The mounting system of the biconical radiators ensures fixed orientation of the crossbars leading to high reproducibility of electrical performance and in line with a recommendation in CISPR 16-1-6 Ed. 1.0 (A.4.2, A.4.3; avoidance of simple screw-thread attached elements that lead to imprecise radiator orientation).

  • Recommended extras
    • Adapter R&S®KM011Z10 (for R&S®HK116E on tripod R&S®HZ-1)
    • Wooden Tripod R&S®HZ-1

Features & Benefits

  • Low frequency dependence of the radiation patterns
  • Very low cross polarization permits accurate spatial determination of the electrical field vector
  • Compliant with requirements for balun imbalance and cross-polar performance given in CISPR 16-1-4 Ed. 3.0 (sec. 4.5.4, 4.5.5)
  • Dimensions are compliant with MIL-STD-416A
  • Wide frequency range
  • Individual calibration in line with ANSI C63.5 (free-space calibration) and ARP 958
  • Easy and quick way to mount/demount the biconical radiators
  • Low weight

Specifications

R&S®HK116E
 
Frequency range 20 MHz to 300 MHz
Polarization linear
Input impedance 50 Ω
VSWR typ. 2.5
Permissible input power 75 W CW
Connector N female
Operating temperature range –40 °C to +55 °C
MTBF >150 000 h
Dimensions (L × W × H) approx. 1380 mm × 530 mm × 780 mm
Weight approx. 3 kg
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Get a Demo

Please enter your inquiry.
Please enter your first name.
Please enter your name.
Please enter a valid email address.
Please enter your company name.
Please enter your city name.
Please enter your postal code.

Please enter your location.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

Please enter the characters shown in the image
show captcha
The input was not correct.
Do not enter data in this field
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Get a Quote

Please enter your inquiry.
Please enter your first name.
Please enter your name.
Please enter a valid email address.
Please enter your company name.
Please enter your city name.
Please enter your postal code.
Please enter your phone number.

Please enter your location.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

Please enter the characters shown in the image
show captcha
The input was not correct.
Do not enter data in this field
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Request information

Please enter your inquiry.
Please enter your first name.
Please enter your name.
Please enter a valid email address.
Please enter your company name.
Please enter your city name.
Please enter your postal code.

Please enter your location.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

Please enter the characters shown in the image
show captcha
The input was not correct.
Do not enter data in this field
International Website