Question
Which transducer factor do I have to use for LISN HM6050-2?
I want to use it with and without the limiter.
Which transducer factor do I have to use for LISN HM6050-2?
I want to use it with and without the limiter.
When you switch on the limiter, you have to add 10 dB to the measurement result.
Here are the transducer factors with the 10 dB included. You can use the file HM6050_Limiter_TLon.csv directly in HM Explorer (EMC-Pre_Com).
When the limiter is off, we have slightly different transducer factors for the measurement over L1 and N.
Here are the transducer factors for measurement over L1 => HM6050_L1_TLoff.csv
and over N => HM6050_N_TLoff.csv
You can use both files directly in HM Explorer (EMC-Pre_Com).