R&S®ZVAX-TRM Extension Unit

Configurable signal conditioning for measurements on active components

Key Facts

  • Extension unit for an R&S®ZVA/ZVT network analyzer for measurements on T/R modules, receivers, transceivers and power amplifiers
  • Base unit supports power levels up to +43 dBm
  • Options for pulse modulation, amplification, high-power, noise figure and intermodulation measurements

Brief Description

The configurable R&S®ZVAX‑TRM extension unit is used together with an R&S®ZVA/ZVT network analyzer to provide signal conditioning for demanding measurements on active DUTs.

Features

  • Configurable test system for characterizing T/R modules
  • Excellent performance data for measurements on T/R modules
  • Customized configuration

Specifications

 
Maximum input power at test port +43 dBm
Rise Time < 5 ns, typ. 1 ns
On/off ratio at 10 GHz > 60 dB

Key Facts

  • Extension unit for an R&S®ZVA/ZVT network analyzer for measurements on T/R modules, receivers, transceivers and power amplifiers
  • Base unit supports power levels up to +43 dBm
  • Options for pulse modulation, amplification, high-power, noise figure and intermodulation measurements
  • R&S®ZVAX‑TRM models up to 24/40/50/67 GHz
  • Flexible configuration for the required application
  • Straightforward dialogs for measurement configuration
  • Automatic detection and control of R&S®ZVAX‑TRM via USB interface

Brief Description

The configurable R&S®ZVAX‑TRM extension unit is used together with an R&S®ZVA / R&S®ZVT (the R&S®ZVAX-TRM24/40/50/67 can be combined with any R&S®ZVA8/24/40/50/67 or R&S®ZVT8/20 network analyzer; the extension unit is supplied as standard with the RF interconnection cables for the corresponding R&S®ZVA24/40/50/67 model) network analyzer to provide signal conditioning for demanding measurements on active DUTs. For example, it allows measurements on pulsed signals or noise figure measurements on transmit/ receive (T/R) modules. Together with an R&S®ZVA network analyzer, the R&S®ZVAX‑TRM provides costomized test sets for applications up to 24/40/50/67 GHz (restrictions on some options for the 67 GHz model).

Features & Benefits

  • Configurable test system for characterizing T/R modules
    • R&S®ZVAX-TRM decouples signal conditioning from the network analyzer
    • Fewer options needed for the network analyzer itself, reduced investment costs
    • Basic configuration supports high-power two-port measurements up to +43 dBm
    • Test set can be expanded with options
    • Signal access points in the R&S®ZVAX-TRM for integrating external components and instruments
  • Excellent performance data for measurements on T/R modules
    • Measure a T/R module’s characteristics in both directions
    • E.g. bidirectional pulse measurements
    • High output power levels even with a fully configured R&S®ZVAX-TRM
  • Customized configuration
    • R&S®ZVAX‑TRM base unit
    • R&S®ZVAXxxB712/B73 pulse modulators
    • R&S®ZVAXxxB112/B134 output amplifiers
    • R&S®ZVAXxxB213/B224 combiners
    • R&S®ZVAXxxB31/B32 Pre-amplifier, receiver path 1/2
  • Typical system configurations
    • Measurements on T/R modules with combined transmit/ receive ports
    • Measurements on T/R modules with an input circulator (three ports)
    • High-power and hot S22 measurements

Specifications

Key specifications
Maximum input power at test port base unit +43 dBm 1)
Rise time R&S®ZVAXxxB712/B73 pulse modulator options <5 ns, typ. 1ns
On/off ratio at 10 GHz R&S®ZVAXxxB712/B73 pulse modulator options >60 dB
 Pulse droop R&S®ZVAXxxB712/B73 pulse modulator options typ. 0.05 dB
 Trigger delay R&S®ZVAXxxB712/B73 pulse modulator options <25 ns
 Output power (with all options installed, -5 db input power) R&S®ZVAXxxB112/B134 output amplifier options > 5 dBm (higher output power with less options installed or higher input power)
Dynamic range with all options installed up to 24 GHz >120 dB
Dynamic range with all options installed up to 40 GHz >110 dB
Dynamic range with all options installed up to 50 GHz >100 dB
Dynamic range with all options installed up to 67 GHz >90 dB

1) Higher powers can be provided and handled by using external components, e.g. preamplifier, attenuator, etc.

Благодарим вас.

Ваш запрос был успешно отправлен!

Мы свяжемся с Вами в ближайшее время.

Коллектив Rohde & Schwarz

Получить на тест

Введите текст запроса.
Введите свое имя.
Введите свое имя.
Введите действующий адрес электронной почты.
Введите название компании.
Введите город.
Введите почтовый индекс.

Укажите свою страну.
Введите символы, показанные на изображении
show captcha
Введена недействительная информация.
Do not enter data in this field
Благодарим вас.

Ваш запрос был успешно отправлен!

Мы свяжемся с Вами в ближайшее время.

Коллектив Rohde & Schwarz

Узнать цену

Введите текст запроса.
Введите свое имя.
Введите свое имя.
Введите действующий адрес электронной почты.
Введите название компании.
Введите город.
Введите почтовый индекс.
Введите номер телефона.

Укажите свою страну.
Введите символы, показанные на изображении
show captcha
Введена недействительная информация.
Do not enter data in this field
Благодарим вас.

Ваш запрос был успешно отправлен!

Мы свяжемся с Вами в ближайшее время.

Коллектив Rohde & Schwarz

Запросить информацию

Введите текст запроса.
Введите свое имя.
Введите свое имя.
Введите действующий адрес электронной почты.
Введите название компании.
Введите город.
Введите почтовый индекс.

Укажите свою страну.
Введите символы, показанные на изображении
show captcha
Введена недействительная информация.
Do not enter data in this field
International Website