153 Results
R&S®ZNB40, ZNB40, Vector Network Analyzer, Rohde & Schwarz is the first to introduce a 40 GHz midrange vector network analyzer with four ports and a second internal signal source for mixer measurements.
Introduction to Attribute Based Instrument Drivers
01-Dec-2012 | AN-No. 1MA170
26-Mar-2024
embedded world 2024: Rohde & Schwarz presents its cutting-edge test solutions for embedded systemsRohde & Schwarz offers comprehensive test and measurement solutions for embedded design challenges for today’s requirements for efficiency, safety, reliability and interoperability. The highlights will be showcased at the embedded world Exhibition & Conference 2024 in Nuremberg, Germany.
This application note shows how to measure the phase accurately between several signals using vector network analyzers of the R&S®ZNA, R&S®ZNB and R&S®ZNBT families.
11-Jul-2019 | AN-No. 1EZ82
Ensures compliance of high speed Ethernet cable assemblies with fast automation and easy testing.
04-Oct-2022
With continuously increasing data rates, signal integrity in high speed digital designs becomes more and more demanding
08-Jul-2022
The ZNB20 is used to measure the performance of this cable assembly against the OPEN Alliance TC9 standard. Sdd11 Return Loss, Sdd21 Insertion Loss and propagation delay are measured. Automotive Ethernet, Multigabit Ethernet Test, Ethernet Link Segment Test
This application note provides practical hints to accurately characterize and de-embed these lead-in and lead-out structures with R&S Vector Network Analyzers ZNA, ZNB, ZNBT and ZND.
19-Sep-2022 | AN-No. 1SL367
14-Jul-2022
Granite River Labs and Rohde & Schwarz extend partnership to broaden European test lab’s compliance testing capabilitiesHaving recently opened their new state-of-the-art high-speed digital compliance test laboratory in Germany, Granite River Labs (GRL) has now further extended their scope of industry services for a growing European market. By adding the R&S ZNB20 vector network analyzer from Rohde & Schwarz to complement the previously acquired R&S RTP164 high-performance oscilloscope, the GRL test lab is able to offer an even broader range of testing services around established and future high-speed digital technologies like Automotive Ethernet or USB.
18-Nov-2020
Rohde & Schwarz and Rosenberger verify MultiGBASE-T1 compliance test according to OPEN Alliance TC9 test specificationTest and measurement specialist Rohde & Schwarz, together with connector and cable assembly manufacturer Rosenberger have successfully demonstrated compliance testing for MultiGBASE-T1 supporting 2.5/5/10GBASE-T1 automotive Ethernet speeds, based on the OPEN Alliance TC9 working group test specification. This development enables vehicle manufacturers and component suppliers to have confidence in the performance of future, high-speed in-vehicle networks.
Nonlinear applications using Rohde & Schwarz vector network analyzers - Product Flyer
I would like to use the ZNB as a signal generator. I need a CW signal on port 1 and port 3 with different frequencies. How can I get that?
Instrument Security for R&S®ZNB/ZNBT/ZNC/ZND
ZNB - several channels with external trigger
Remote Desktop screen size of ZNB/ZND
ZNB - How to disable Sweep Position Display Symbols
ZNA/ZNB: Export all mixed mode S-Parameters
ZNB: Power off at sweep end possible?
I have used my TRL calibration kit with my ZVA before. Now I want to use also with my ZNB. But when I try to load the data of the calibration kit into the ZNB, the above error message is shown.
ZNB - print to file command does not work anymore
ZNB/ZND - wrong connector type shown at Cal Unit Characterization
ZNA, ZNB, ZND - Power off after stop of the Sweep?
Rohde & Schwarz Getting Started with the R&S®ZNB/ZNBT Vector Network Analyzer
The R&S®ZNB vector network analyzer offers solid RF performance for everyday needs.
Is there a way to use the hard keys when using the ZNB via Remote Desktop connection? On my unit I only see the standard menu to the lower left side of the device, but have no access to the "master keyboard"
I want to do a calibration with 75 Ohms at the ZNB/ZND/ZVA. Do these VNAs accept the auto cal unit ZV-Z53 with 75 Ohms impedance?
For maximum accuracy in characterizing various components with fixtures, the R&S®ZNB has several industry standard de-embedding tools integrated in the R&S®ZNB Firmware For maximum accuracy in characterizing various components with fixtures, the R&S®ZNB has several industry standard de-embedding tools integrated in the R&S®ZNB Firmware. vector network analyzer ZNB, Test and Measurement, network analyzers
R&S®ZNB, ZNB, Vector Network Analyzer, More than 60 years of experience in the field of vector network analysis pay off: Rohde & Schwarz once again sets new benchmarks -- with the R&S®ZNB.
The R&S®ZNB vector network analyzer is leading in speed, dynamic range and ease of operation. Compact size, low power consumption and light weight makes the R&S®ZNB ideal for use in production. Video, ZNB, vector network analyzer The R&S®ZNB vector network analyzer is leading in speed, dynamic range and ease of operation.
How do I use the driver correctly?