Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
735 Results
RTC, RTC1000, Application Card, Determining current-voltage characteristics with the oscilloscope With their included component tester, the R&S®RTC1000 oscilloscopes are universally deployable in development and educational environments. Determining current-voltage characteristics with the oscilloscope RTC, RTC1000, Application Card, Determining current-voltage characteristics with the oscilloscope
20-Dec-2017
Rohde & Schwarz has made a breakthrough for better jitter and noise separation with the launch of SW options (RT-K133 & RT-K134). Technical information on this new algorithm were presented at . We received a lot of positive feedback on this new technique. However, one fundamental question still remained. How does this new algorithm compare to established solutions available on the market today?This app note provides an introduction into the various jitter components and elucidates the commonly available jitter separation frameworks. Finally, it provides a comparison between the different commercial solutions, while explaining the used waveforms and signals to achieve the results. Curios? Read on, to learn how Rohde & Schwarz’s new option for jitter and noise separation delivers dependable and stable results. If you are interested in evaluating on your own, you may download the waveform files with registration.
08-Dec-2021 | AN-No. 1SL375
This application note reviews a new calibration subsystem which consists of Inline Calibration Units (ICUs). These ICUs are designed for in situ use, so they are left in place both during the calibration procedure and during the measurement of the Device Under Test (DUT).This adds versatility, convenience and accuracy to the VNA based measurement system, as it means the calibration can be refreshed at any time without manually disconnecting the DUT from the test system.
29-Sep-2017 | AN-No. 1EZ71
This application note shows how to remote control the switching of RF and digital I/O signals by R&S®OSP Open Switch and Control Platform directly from a Vector Network Analyzer (VNA) or from a Spectrum Analyzer (SA). The R&S®ZVA, R&S®ZVB, R&S®ZNB, R&S®FSW and R&S®FSV families are covered. The application note first describes the requirements and setup procedure. It is shown how to install the software and how to set up the system in order to get highest flexibility and best usability. It is then shown how to calibrate the entire configuration and finally some practical examples are provided. Switching is explained using VNAs as an example, the appendix 5.4 provides hints regarding the differences when using SAs in a similar way.
06-Dec-2013 | AN-No. 1MA226
The aim of this application note is to provide information regarding Rohde & Schwarz instrument drivers. This paper shall help application engineers and software developers to easily get an understanding of advanced techniques to develop test and measurement (T&M) applications by utilizing Rohde & Schwarz instrument drivers. Furthermore the nomenclature used for Rohde & Schwarz instrument drivers will be explained.
01-Jan-2013 | AN-No. 1MA153
This application note discusses the use of the WOOSHCOM® DHEI output interface adapter (model 3010), which converts the transport stream from DHEI format into DVB-ASI. Further processing and analysis of the transport stream signal then becomes available with any of the Rohde & Schwarz Test & Measurement instruments. It also describes how to extract an unencrypted transport streams out of a Motorola IRT.
08-Jun-2004 | AN-No. 7BM40
The R&S®SMBV100A vector signal generator offers a remote emulation feature that makes it possible to control the instrument by commands other than the built-in native SCPI commands. This feature allows the user to replace signal generators, e.g. from other manufacturers, with the R&S®SMBV100A without having to change the remote control code. This application note describes how to use the remote emulation feature in general. Furthermore, it describes in detail the remote emulation for each supported instrument, limitations of the individual emulations and the remaining differences between the emulated and the original commands.
11-Oct-2016 | AN-No. 1GP91
Simultaneous DL throughput verification and UL transmission testing with the R&S®CMW500
29-Jul-2009
Test time is a critical parameter when it comes to evaluating the cost of test.This application note describes typical spectrum analyzer measurements in production environments and discusses different approaches to speed them up.
17-Nov-2014 | AN-No. 1EF90
This application note describes the software configuration, system calibration and test routine for EMC measurements according to the EMS standard IEC / EN 61000-4-6.
29-Mar-2007 | AN-No. 1SP33
TDMA communications systems like GSM, DCS 1800 or PCS 1900 make effective use of the frequency spectrum by assigning several subscribers to the same frequency channel. Each subscriber has access to one predefined time slot for transmitting information. With GSM eight subscribers share one frequency channel with a bandwidth of 200 kHz. In order not to disturb the other users of the 200-kHz channel it has to be ensured that, for instance, a mobile sends in the assigned time slot only and that no power is emitted by the transmitter at other times. For this reason the transmitter power is practically switched off in the transmission intervals.
16-Jan-2002 | AN-No. 1EF18
This Application Note provides a step-by-step description of all video decoding settings you need to make. It also contains valuable information about how to optimize replay for various applications.
02-Mar-2006 | AN-No. 7BM52
Test Solutions Based on R&S®CMX500 Platform
The evolution of mobile communication enters 5G New Radio (NR) era with pivotal features. Voice call service is however still considered as an indispensable element for mobile devices and worldwide network operators continue to maintain the voice service for their subscribers. In comparison to other Over-the-Top (OTT) voice services, such as WhatsApp©, Teams© etc., Voice over NR (VoNR) and Voice over LTE (VoLTE) maintain QoS, support well established handover mechanism and emergency call, and do not require to pre-install OTT app on the phone.In order to provide premium voice service and enhance the superb user experience, audio tests on mobile devices are essential before the product launch. Different audio test aspects among which acoustic, functional, performance and field tests need to be considered.This application note describes the performance test with focus on VoNR audio quality measurement via electrical interface of the mobile device. The test solution is based on R&S®CMX500 with its integrated POLQA algorithm.
26-Jul-2023 | AN-No. 1SL401
The following application note describes the function and operation of user menus for FSE Spectrum Analyzers including option Vector Signal Analysis (FSE-B7). For measurements according to the PCS 1900 standard user menus are provided, which perform settings on FSE for Base Station testing required in the standard. The menu and the accompanying setups are stored on a floppy disk. For operation of the menus firmware version 1.40 or higher is required. Option Vector Signal Analysis FSE-B7 has to be installed for the use of the application menu.
17-Jan-2002 | AN-No. 1EF24
This application note provides a brief introduction into the capabilities of the Rohde & Schwarz Vector Signal Generators (VSG) to create user defined digitally modulated signals called Custom Digital Modulation (CDM). Additionally an in depth description of the functions and the operation of the CDM-Toolbox is provided. The CDM-Toolbox is application software which allows an easy remote configuration of CDM signals on Rohde & Schwarz VSGs but also the creation of data list and control list files which are most useful to further extend the application area of CDM signals.
24-Jul-2017 | AN-No. 1GP96
A special requirement for testing GSM components is to measure the electrical characteristics, such as the gain of a power amplifier, of the DUT under pulsed conditions. The test should be similar to real operating conditions for a mobile telephone.
28-Jul-1998 | AN-No. 1EZ42
Measuring the spurious emissions of transmitters used in GSM, DCS 1800 and PCS 1900 networks requires highly complex test setups since con-ventional spectrum analyzers do not have the necessary dynamic range. To obtain this range, notch filters are used to suppress the useful sig-nal. The spectrum analyzers of the FSE family make it possible for the first time to verify com-pliance with stipulated limit values for spurious emissions within the transmission band and out-side the reception band without the use of notch filters. The measurement problem and its solution by means of FSE are described in the following by way of the example of a GSM base station.
16-Jan-2002 | AN-No. 1EF17
Your measurement task: To analyze an RF module via its digital interface. This Application Note explains how. As interfaces between the baseband and the RF modules of mobile radio base stations and terminals are increasingly digital, instruments for testing such modules need digital baseband interfaces as well. The R&S®EX-IQ-Box is a digital interface adapter that provides digital baseband I/O for Rohde & Schwarz signal generators and signal analyzers. An R&S signal analyzer with digital baseband interface R&S®FSQ-B17 can analyze digital baseband components input from the R&S®EX-IQ-Box. Data collected with a test-setup consisting of an R&S signal analyzer and the digital interface adapter R&S®EX-IQ-Box can be used in an Agilent ADS environment. For details of how to input the results to ADS, see Application Note 1MA72: 'Using R&S® Instruments within Agilent®ADS®Software'
26-Jun-2009 | AN-No. 1MA147
With the R&S®RTB2000/RTM3000/RTA4000 oscilloscopes, you control and interact remotely via LAN. These oscilloscopes incorporate the USB-based connectivity standard media transfer protocol (MTP).
20-Mar-2017
This Application Note introduces HSDPA technology and test and measurement requirements according to 3GPP release 5 specifications. Important HSDPA measurements and example applications are illustrated by means of Rohde & Schwarz products.
01-Feb-2005 | AN-No. 1MA82
The R&S®SMC100A signal generator offers a remote emulation feature that makes it possible to control the instrument by commands other than the built-in native SCPI commands. This feature allows the user to replace signal generators, e.g. from other manufacturers, with the R&S®SMC100A without having to change the remote control code. This application note describes how to use the remote emulation feature in general. Furthermore, it describes in detail the remote emulation for each supported instrument, limitations of the individual emulations and the remaining differences between the emulated and the original commands.
28-Feb-2012 | AN-No. 1GP90
Level or power measurement of especially modulated signals using spectrum analyzers is becoming more and more important . Whereas the first choice in terms of accuracy for power measurement of any carrier (modulated or non-modulated) is a power meter, power measurement of spurious or in the adjacent channel of a transmission system needs a selective power meter with high dynamic range. A power meter, however, is a non-selective device with limited dynamic range and is not appropriate for these types of measurements. The first choice is a spectrum analyzer because of its versatile use as a general-purpose instrument. Compared to a power meter its power measurement accuracy is worse. In general this can be overcome by substitution methods using a power meter, an attenuator and a signal generator. But substitution is time-consuming and requires more investment in test equipment than a single instrument. Therefore it is most important to have a spectrum analyzer like the FSE, which can fulfill at least most of the requirements in terms of measurement accuracy.
13-Jan-1998 | AN-No. 1EF36
This Application Note gives 10 useful Tips & Tricks for the users of Rohde & Schwarz attribute-based instrument drivers. It is recommended for the first-time LabVIEW users as well as for the experienced programmers.
30-Jan-2017 | AN-No. 1MA228
Analog-to-digital converters (ADCs) have taken giant steps in speed and accuracy over the past years: Such devices allow high-speed video processing and even software defined radio (SDR) applications, where digitization is being performed at ever-higher intermediate frequencies (IF). This has clearly raised the bar for ADC test equipment, especially regarding the noise performance of the analog input signal and sample clock sources used in the test setup. The R&S®SMA100B offers outputs for the analog input signal of the ADC as well as the clock input signal in one single instrument - both with outstanding signal purity.
11-Jan-2021 | AN-No. 1GP66
Measuring cable characteristics is important when it comes to installing and servicing cable TV systems. Cable pinches or poor connections considerably influence the characteristics of cable TV systems. This document shows how the measurement is carried out in a 75 Ohm system. The basics of distance-to-fault measurements, the test setup, calibration and measurement are discussed.
21-Sep-2006 | AN-No. 7BM60
An FSE Spectrum Analyser equipped with the Vector Signal Analysis option (FSE-B7) can measure oscillator settling time or transmitter attack and release times with high accuracy up to 40 GHz. No additional measurement equipment is needed.
12-Feb-1999 | AN-No. 1MA15
The aim of channel sounding is to characterize a radio channel by decomposing the radio propagation path into its individual multipath components. This application note provided by Neul describes how channel sounding can be performed using the R&S SMBV100A Vector Signal Generator and the R&S FSL Spectrum Analyzer. To illustrate the procedure reference is made to 8 MHz wide white space channels in the UK.
13-Jul-2011 | AN-No. 1MA199
Vector network analyzers are used in high frequency applications to measure the complex scattering parameters of an unknown device-under-test (DUT). In general, the DUT characteristics can be evaluated by using electromagnetic waves. The correlation between the incident, reflected and transmitted wave quantities at the DUT is defined by its scattering matrix S.
28-Jul-1998 | AN-No. 1EZ30
- not available -
02-Nov-2009 | AN-No. 7BM14