31 Results
Release Notes (1) Title Size Version Date Touch Monitor Update Release Note Version 1.01 32Bit Release Notes including information for Installation 148 kB 1.01 12.08.2016 Software (1) Title Size Version Date Touch Monitor Update Release Note Version 1.01 32Bit Release Notes including information for Installation
I already have ESR/ESW Receivers and I would like to know, if this existing device can be calibrated as required by CISPR 16-1-1:2019 (Ed.5)?
Scan Table, exclamation mark appears near to the Bandwidth setting.
FAQ - Remote command „CALC:UNIT:POW DBUV” is not accepted
Self Alignment via remote control via TCP/IP => 'CAL?
I have a file on my device. How can I get it in a simple way to my PC?
The LCR meters R&S®LCX100 and R&S®LCX200 precisely measure the complex impedance and the resulting components values over a wide frequency range.
14-Mar-2022 | AN-No. 1GP132
Security, Manual, ESR, EMI Text Receiver
R&S®ESR-K55 User Manual
Rohde & Schwarz user manual for the R&S®ESR Test Receiver; it provides all the information specific to the instrument. Other operating modes and applications are described in the specific application manuals.
R&S®ESR Quick Start Guide
Windows XP or other instruments are not affected. 1.3 21.10.2019 1 MB R&S®ESR Firmware V 3.48 SP3 25.09.2020 561 MB R&S®ESR Release Note V 3.48 SP3 25.09.2020 417 kB R&S®ESR - Firmware V3.66 17.11.2021 293 kB R&S®ESR Open Source Acknowledgment 08 09.09.2019 832 kB Remote Access RS instruments in light of CVE-2018
Firmware for ESR3 Title Versions Last Modified File Size R&S®ESR - Firmware V3.66 17.11.2021 293 kB
Firmware for ESR26 Title Versions Last Modified File Size R&S®ESR - Firmware V3.66 17.11.2021 293 kB
Firmware for ESR7 Title Versions Last Modified File Size R&S®ESR - Firmware V3.66 17.11.2021 293 kB
This application note provides a description of the Rohde & Schwarz Click Rate Analyzer software.
15-Jan-2015 | AN-No. 1EE25
04-Dec-2017
Rohde & Schwarz supports ESA JUICE expeditionRohde & Schwarz provided 2 R&S ESR EMI test receivers to support tests in the ESA JUICE expedition to Jupiter in 2022.
The paper compares the measurement speed and level measurement accuracy of a conventional stepped frequency scan versus an advanced FFT-based time domain scan.
29-Jan-2014 | AN-No. 1EE24
This paper describes the characterization of aluminum electrolytic capacitors specifically used in AC-DC power converter applications. It will be discussed why this capacitor technology is critical regarding lifetime and why it cannot be substituted simply by any another capacitor technology. Different aging effects of the capacitor will be discussed. Usage of the capacitor in different AC-DC converter topologies will be presented. Simulation circuits will be used to analyze the capacitor in more detail before suitable measurements will be performed to demonstrate a real example of a switching-mode power supply (SMPS).After the introduction into the aluminum electrolytic capacitor basics and theory, this paper will also present all important and possible measurements of capacitor parameters, like capacitance, equivalent series resistance (ESR) and ripple current. This includes in-circuit measurement which can be performed with an oscilloscope. An LCR-bridge is used to obtain high accuracy measurements in addition. A comparison between the two measurement methods will be presented. Furthermore, the required measurement hardware for the in-circuit measurements and the bridge measurement will be discussed and presented.Lastly, two different lifetime calculation methods are presented and a real example is used to compare the advantages and disadvantages of the different methods.Thanks to Mr. Frank Puhane from Würth eiSos GmbH & Co. KG who provided me with all aluminum electrolytic capacitor samples including the prepared capacitor with build-in temperature sensors to perform all measurements. Furthermore, his great expertise was very beneficial and helpful to create this premium application note.
07-Feb-2023 | AN-No. 1SL388
Each product Driver Information (3) File Description Date LabVIEW driver rsemi history 14.12.2016 LabWindows/CVI, VXIpnp driver rsemi history 14.12.2016 IVI.NET driver RsEmi history 14.12.2016 Instrument Drivers (6) Driver Name Size Version Date LabVIEW 2010 driver rsemi Please read the LabVIEW driver history for installation instructions
This application note shows how to configure, calibrate and perform conducted EMS measurements according to IEC / EN 61000-4-6 and EMI measurements according to CISPR 16-2-1 with the R&S®EMC32 software tool.
19-Jul-2013 | AN-No. 1MA212
Assisting Tools for Operation of Windows-Based T&M Instruments
13-Jun-2013 | AN-No. 1MA218
This document describes how a Windows®-based R&S® T&M instrument is remotely operated by an Android™ tablet as if working on it locally.
22-Aug-2013 | AN-No. 1MA236
This document describes how a Windows®-based R&S® T&M instrument is remotely operated by an Apple iPad as if working on it locally.
28-Mar-2013 | AN-No. 1MA216
27-Feb-2020
Testing automotive electronics: Rohde & Schwarz exhibits fast, robust and compact test solutions at EMV 2020Today's vehicles contain more and more electronics with RF technology, radio components, radars and high speed data buses. This makes it difficult for automobile manufacturers to ensure that electronic emissions remain within specified limits and that vehicles are not susceptible to external interference sources. That's why, at EMV 2020 in Cologne (Germany), Rohde & Schwarz will present EMC test solutions specifically for users in the automotive industry: the fastest CISPR-25 certification, a robust and compact BCI test system, and R&S AdVISE version 5, which keeps a close eye even on vibrating display elements during EMS tests.
08-Mar-2017
T&M equipment from EMC expert Rohde & Schwarz at EMV 2017 in StuttgartRohde & Schwarz again demonstrates its expertise in electromagnetic compatibility (EMC) measurements at the EMV 2017 international trade fair in Stuttgart.
06-Mar-2019
EMV 2019: Rohde & Schwarz adds new automated EMC test solutions to its EMC test portfolioAt EMV in Stuttgart, Rohde & Schwarz will demonstrate highlights such as the new R&S ELEKTRA EMC test software for automated certification and precompliance tests and R&S AdVISE for automated visual checks. Brand new are the test solutions for spurious emission measurements for 5G components.
13-Feb-2018
Rohde & Schwarz will demonstrate its comprehensive expertise in EMC test and measurement at EMV 2018At EMV 2018, Rohde & Schwarz will present its customized solutions for EMC measurements in all areas of product development, from the R&D phase to certification. A turnkey test system for certification testing in line with RED as well as complete systems for immunity measurements will also be on display.