Rohde & Schwarz solution
The LMG600 power analyzer series provides a turnkey compliance test solution for harmonic current emissions (IEC/EN 61000-3-2) and voltage flicker (IEC/EN 61000-3-3) up to 16 A, integrating a power analyzer, clean AC source and the LMG test suite software. For higher requirements, the system can be extended to support IEC/EN 61000-3-12 and IEC/EN 61000-3-11 tests up to 75 A using additional third-party components. The results are repeatable, traceable and deliver a compliant pass/fail decision from early development through product release.
Harmonics and flicker testing
Harmonics compliance confirms that a product’s input current spectrum stays within defined standard limits. Testing is performed under steady operating conditions using a clean AC source to ensure accuracy. By comparing measured results against standard set values, the process provides a definitive pass/fail decision that secures overall regulatory compliance. This requires certified test equipment and dedicated compliance software.
Flicker compliance testing evaluates voltage fluctuations caused by current variations in the equipment under test (EUT). By applying standardized operating sequences and load steps, the system measures disturbance metrics against established voltage limits. Using a reference impedance source, such as the RI2415 reference impedance for compliance tests in line with IEC/EN 61000-3-3/-11, ensures these measurements are accurate. Together, harmonics and flicker testing confirms that a product behaves as a good grid citizen and does not interfere with the power grid.
LMG test suite software
The LMG test suite works with the LMG600 power analyzer series to perform EMC compliance testing. Measurements are available via real-time online analysis or through stored offline data records. This flexibility extends to hardware compatibility, as the software supports all CE-compliant AC power sources on the market.
The software generates comprehensive PDF test reports, including results and essential electrical properties such as RMS values, power factor and harmonic distortion. These documents feature graphical comparisons of results against standard limits, as well as full documentation of equipment settings and test structures. To eliminate manual post-editing, reports can be customized with company information and design elements for a professional finish.
Supported standards include IEC/EN 61000-3-2/-12 (harmonic emissions) and IEC/EN 61000-3-3/-11 (flicker disturbance). The software also enables standby power measurements (IEC 62301:2011 and EN 50564) and vehicle electromagnetic compatibility testing (ECE R-10.4 Annex 11). The LMG600 series performs harmonic analysis and flicker measurement in line with IEC/EN 61000-4-7 and IEC/EN 61000-4-15. A full list of supported standards can be provided on request.