SENT

Triggering and decoding

SENT Serial Triggering and Decoding
Open Lightbox
SENT Serial Triggering and Decoding
Open Lightbox
SENT Serial Triggering and Decoding
Open Lightbox
SENT Serial Triggering and Decoding
Open Lightbox
SENT Serial Triggering and Decoding
Open Lightbox
SENT Serial Triggering and Decoding
Open Lightbox
SENT Serial Triggering and Decoding
Open Lightbox
SENT Serial Triggering and Decoding SENT Serial Triggering and Decoding SENT Serial Triggering and Decoding SENT Serial Triggering and Decoding SENT Serial Triggering and Decoding SENT Serial Triggering and Decoding SENT Serial Triggering and Decoding

Key facts

  • Decode in different formats, including fast and slow serial messages, e.g. in HEX, binary or unsigned format
  • Symbolic decoding support to show messages in physical units, e.g. temperature or pressure
  • Display of fast and slow (short and enhanced) serial messages as two separate color-coded bus signals as well as in tabular format
  • Flexible trigger capability on fast and slow channel. Trigger on various error conditions, including fast and slow channel CRC errors, timing and pulse period errors
  • Support of the different CRC checksum calculations in line with TLE 4998X and SAE J2716, v2008 and v2010
  • R&S oscilloscopes | Engineered for multi-domain challenges

Oscilloscope software

R&S®RTO/RTE/RTH oscilloscopes support triggering and decoding, including symbolic decoding. You can set up decoding in seconds. For analysis, results can be viewed as color-coded telegrams and in a table. Errors are identified efficently using the hardware-accelerated trigger. You can trigger on fast channel (calibration, sync, status, data), slow channel (ID and data) and various error conditions.

Features & benefits

Fast bus setup

Bus setup in seconds with the app cockpit

Starting from the app cockpit, it only takes a few steps to configure any given protocol. Once the bus to decode has been chosen, the connected channels selected and the correct levels set, decoding begins automatically.

Open Lightbox

Bus decoding selection with the app cockpit.

Color-coded telegram display

Telegram display as color-coded bus signals and in decode table

You can analyze the decoded bus frames with a color-coded data overlay over the bus signal. Address and data content can be displayed in hex, bin or ASCII format. You always have the best overview with the flexible screen setup. Additionally, the telegrams can be displayed in a concise table.

Open Lightbox

Decoded frames are color-coded.

Strong trigger capability

Strong trigger capability on FAST channel (calibration, sync, status, data), SLOW channel (ID and data) and various error conditions

The protocol-specific trigger lets you reliably isolate protocol events and errors. Thanks to high acquisition rates, Rhode & Schwarz oscilloscopes are ideal for finding errors quickly, allowing decoding of protocol-specific trigger results. The hardware-based triggering is available on specific protocol content, e.g. addresses, data and protocol errors. 

Open Lightbox

Protocol trigger setup dialog.

Search and navigate in recorded acquisitions

Powerful search and navigate capability

Comprehensive search functions simplify the analysis of long signal sequences. You can search for waveforms based on different criteria, such as signal faults or protocol content. All detected events are shown in a table with timestamps. The individual events can be examined in a zoom window with simple navigation between events.

Open Lightbox

Powerful search even in long recordings.

Available models


  • Option Name

    R&S®RTO-K10

    Order number 1329.7354.02

    Serial Standard
    SENT
    Decode Table
    Trigger
    Label Support
    Base unit
  • Option Name

    R&S®RTE-K10

    Order number 1323.1603.02

    Serial Standard
    SENT
    Decode Table
    Trigger
    Label Support
    Base unit
  • Option Name

    R&S®RTH-K10

    Order number 1326.3835.02

    Serial Standard
    SENT
    Decode Table
    Trigger
    Label Support
     

More information

  • Safe debugging of embedded power supplies

    Debug embedded power supplies faster by triggering and decoding their I²C-based control interfaces.

    More information

  • Triggering and decoding of low speed serial buses

    Triggering and decoding low speed serial buses

    Illustrates how to trigger and decode I²C and SPI protocols with Rohde & Schwarz oscilloscopes

    More information

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

I want to receive information from Rohde & Schwarz via

What does this mean in detail?

I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Prices and offers are only intended for entrepreneurs and not for private end consumers.