This application note describes how to directly transfer S-Parameter Trace Data from R&S Network Analyzers to Microsoft Excel using a direct connection like GPIB or LAN. Prerequisites are a PC running Microsoft Excel, a R&S Network analyzer like ZVA, ZVB or ZVT as well as a working remote control connection between PC and instrument like GPIB or LAN / Ethernet.
22-Mar-2007 | AN-No. RSI02
An operator of a network of terrestrial transmitter stations wants to have the most cost-effective means of monitoring the network's numerous transmitter sites from a main monitoring center. Modern error sensors such as the R&S DVM50/100 and the R&S ETX-T are used for diverse monitoring functions at the individual transmitter sites as well as to transmit monitoring status to the main monitoring center. These error sensors have a function-rich SNMP agent designed specifically for this purpose. Simple network management protocol (SNMP). Despite the 'simple' in the protocol name, some users are still afraid to use it for remote control and monitoring. This Application Note therefore provides a user-friendly and practical look at, for example, how the monitoring functions via SNMP can be used for the R&S DVM. The following sections provide a brief look at the SNMP protocol, the R&S DVM/ETX implementation, and useful tools for working with SNMP. A description of how SNMP can be linked to various development environments (C++, C#, Java) is also provided.
16-Mar-2007 | AN-No. 7BM65
This document describes typical measurements that are required to be made on amplifiers and how the measurement can be implemented on the ZVB Vector Network Analyzer. The document describes the concepts and setups required to perform Gain, Isolation, input impedance measurements, then goes on to describe how more uncommon measurements are made with the ZVB like Harmonics, Stability Factor and compression point.
07-Feb-2007 | AN-No. 1EZ54
Testing the tolerance to phase and impulsive noise is an integral part of quality tests for DVB-T/H and ATSC (8VSB) receivers, and several national and international standards specify guidelines and minimum requirements in this context. This Application Note introduces the R&S SFU-K42 impulsive noise option, the R&S SFU-K41 phase noise option, as well as the R&S SFU-K43 multinoise use option and describes how these can be used for testing the tolerance to phase and impulsive noise on commercial receivers.
26-Jan-2007 | AN-No. 7BM64
TS-EMF2 TS-EMF TRD Conversion TRD Conversion TS-EMF2 TS-EMF TRD Conversion Related products
25-Jan-2007 | AN-No. TS-EMF2
This Application Note introduces the new interferer management option, R&S SFU-K37 and describes how this can be used to generate various types of interfering signals for testing the performance of a receiver.
09-Jan-2007 | AN-No. 7BM50
Arbitrary waveform generator – this term encapsulates the wide-ranging capabilities and applications that can be provided by user-definable I/Q baseband signals and a vector signalgenerator. Rohde & Schwarz has developed the R&S WinIQSIM™ software package specifically with this in mind. The first questions a user might ask are: “How do the R&S SFU and R&S WinIQSIM™ interwork and what features are available? This Application Note has been produced to answer these questions.
19-Dec-2006 | AN-No. 7BM57
The measurement of bit error rate (BER) is an important test procedure for determining the performance of a receiving terminal. This is especially important for set top box and chipset manufacturers who need to know if their product is able to meet the specification under a predefined noise condition. This Application Note describes the technique using an Rohde & Schwarz SFU to measure the BER of digital set top boxes.
19-Dec-2006 | AN-No. 7BM51
This Application Note presents a program which combines FM tuner measurements to form automatically running sequences in line with DIN EN60315-4. It is an extension of Application Note 1GA43 and can be used with the Generator R&S SML and the Audio Analyzer R&S UPV or UPL.
15-Dec-2006 | AN-No. RAC-0502-0012
While RF communication signal distortions in nonlinear transmission paths have been predicted theoretically and studied experimentally for various signals, it is interesting to examine a wideband nonlinear system reaction to a wideband 3G signal and a narrowband 2G signal. Research and testing have demonstrated that, while most vital signal parameters remain within the limits specified by applicable standards even if composite signal power approaches specified maximum power, a relatively high level of spurious emissions caused by cross- and intermodulation can result. To avoid degrading both existing and new systems, this and other signal quality issues must be considered when designing and deploying multitechnology systems.
03-Nov-2006 | AN-No. 1MA110
In response to the growing number of WLAN modules that also support a cellular network (converged devices), CTIA published a plan with new tests in August 2006 that certifies Wi-Fi conformance. This Application Note first addresses the transmitter tests of the CTIA plan. For these tests Rohde&Schwarz offers preprogrammed instrument setups. They enable you to perform the measurements on the WLAN test set easily and quickly. Moreover, this Application Note shows how you can check the spectrum transmit mask defined for OFDM by means of only one keystroke on the Rohde&Schwarz spectrum analyzers.
11-Oct-2006 | AN-No. 1MA107
This application note describes how Bluetooth devices are tested and measured using the R&S CMU200/CBT by means of the CMUgo/CBTgo remote control program or manual operation.
06-Oct-2006 | AN-No. 1CM50
Measuring cable characteristics is important when it comes to installing and servicing cable TV systems. Cable pinches or poor connections considerably influence the characteristics of cable TV systems. This document shows how the measurement is carried out in a 75 Ohm system. The basics of distance-to-fault measurements, the test setup, calibration and measurement are discussed.
21-Sep-2006 | AN-No. 7BM60
radio signals, radio services, sensitive radiocommunications systems, radio-controlled landing systems, automatic landing systems, air traffic control, UMS100, ARGUS Automatic monitoring of radio signals at airports interfering with radio services Automatic monitoring of radio signals at airports interfering with radio services radio signals, radio services, sensitive radiocommunications systems, radio-controlled
04-Sep-2006
Monitoring solutions for operators of security radio networks for police, rescue services, ambulances, fire brigades and radio and TV broadcasting transmitters and other regional and national services.
04-Sep-2006
broadcasting transmitters, allocated frequencies, monitoring control center, RF power, Automatic monitoring of emission parameters of registered broadcasting transmitters Automatic monitoring of emission parameters of registered broadcasting transmitters broadcasting transmitters, allocated frequencies, monitoring control center, RF power, Automatic monitoring of emission parameters of registered broadcasting
04-Sep-2006
radio signals, automatic monitoring, interference, RF radiation, frequency spectrum, Automatic monitoring of radio signals interfering with sensitive devices in hospitals Automatic monitoring of radio signals interfering with sensitive devices in hospitals radio signals, automatic monitoring, interference, RF radiation, frequency spectrum, Automatic monitoring of radio signals interfering with sensitive
04-Sep-2006
The FLO in MediaFLO stands for 'forward link only'. MediaFLO technology covers transmission of files and multimedia content to handheld devices. The FLO device minimum performance specification (MPS) was created to ensure that FLO receivers can receive a FLO service that fulfils the compatibility guidelines of the FLO air interface specification. This Application Note shows how the Broadcast Test System R&S SFU from Rohde & Schwarz can be used to generate all test scenarios required by the minimum performance specification.
31-Aug-2006 | AN-No. 7BM62
The fact that cable TV networks are generally located in densely populated areas or extend over large geographical regions makes the presence of line extenders at regular intervals a necessity. Cascading large numbers of amplifiers however calls for excellent noise, SWR and intermodulation distortion specifications for the integrated amplifiers in order to avoid quality of service dropping below minimum acceptable levels. Composite second order, composite triple beat & cross modulation are commonly used figures to specify the performance of CATV equipment. In this application note we describe how to determine these figures with the aid of R&S SMU200A or AFQ100A and SMV vector signal generators.
11-Aug-2006 | AN-No. RAC-0605-016
combination test, optocouplers, compliance test, DUT, coupling factor, Combination test Expanded test method for optocouplers Combination test Expanded test method for optocouplers combination test, optocouplers, compliance test, DUT, coupling factor, Combination test Expanded test method for optocouplers Combination test Expanded test method for optocouplers combination test, optocouplers, compliance
17-Jul-2006
This document presents a simple procedure for network analysis that is more cost-effective than the use of scalar network analyzers. It allows the accurate measurement of the transmission characteristics of filters, amplifiers and frequency converters over a large frequency and dynamic range. In order to reach very high measurement speeds, Rohde & Schwarz signal generators are operated in 'List Mode', and Rohde & Schwarz power meters are operated in 'Buffered Mode.' The required programming for the signal generator and the power meter is illustrated by excerpts from a Visual Basic program which is available, free of charge, upon request.
14-Jul-2006 | AN-No. 1MA101
The new WiMAX radio technology - worldwide interoperability for microwave access - is based on wireless transmission methods defined by the IEEE 802.16 standard. WiMAX has been developed to replace broadband cable networks such as DSL and to enable mobile broadband wireless access. Rohde & Schwarz offers a complete test solution for WiMAX applications by combining its Signal Generator R&S SMU200A and Signal Analyzer R&S FSQ plus the appropriate options.RuS_WiMAX_OFDM is a 10 minutes video on WiMAX OFDM measurements.Please see also 1MA96 for General information about the WiMAX standard and 1MA97 for Generating and analyzing 802.16-2004 and 802.16e-2005 signals.
11-Jul-2006 | AN-No. 1EF57
This Application Note gives an introduction to measurements of WiMAX signals according to standards 80216-2004 and 802.16e-2005. It describes all kind of signal generation from simple signals to multiple-zone signals, also under multipath environment (fading), and covers all signal measurements from power and spectrum analysis, crest factor and CCDF measurement down to bit pattern analysis and modulation measurements.Please see also 1MA96 for General information about the WiMAX standard and 1EF57 for an introduction to the WiMAX standard.
10-Jul-2006 | AN-No. 1MA97
The DVB-H standard is a specification for bringing television broadcast services to handheld receivers. In order to save battery power, data for a specific service is transmitted in short bursts. This type of transmission utilizes special techniques within the transport stream. The R&S DVM offers a wide range of functions to analyze the characteristics of the DVB-H transport stream. This document describes the characteristics of the DVB-H transport stream and shows how the R&S DVM can be used for efficient analysis in research and development, production, and broadcasting.
04-Jul-2006 | AN-No. 7BM59
For customers who have already used automated R&S SFQ setups in development and production, the implementation of the successor instrument results in a need to adjust the SCPI commands formerly used.This document provides an overview on how SCPI commands that are used with the R&S SFQ change with the new test transmitter as well as a cross-reference list in the form of an EXCEL sheet.
23-Jun-2006 | AN-No. 7BM56
The Rohde & Schwarz SFU supports several modes of level setting. This Application Note describes the differences between these modes and especially describes a method to achieve a seamless transition without any impact to the output signal during a change of settings on an Rohde & Schwarz SFU (Firmware version > 1.30).
23-Jun-2006 | AN-No. 7BM54
This application note is one of three papers dealing with the WiMAX standard, covering the theoretical aspects of WiMAX. It gives a detailed overview of the basic concepts of WiMAX (FFT, OFDM, frame structures, etc) and explains the physical standard parts of IEEE 802.16 standards 802.16-2004, corr1 and 802.16e.Please see also 1MA97 for Generating and analyzing 802.16-2004 and 802.16e-2005 signals and 1EF57 for an introduction to the WiMAX standard.
13-Jun-2006 | AN-No. 1MA96
When MPEG-2 transport streams are transmitted, the program clock reference PCR is transmitted as a time reference in the receiver. A sufficiently accurate and correctly received PCR is a precondition for correct data display in the receiver. This Application Note provides an overview of definitions, functions and use of the PCR. It also explains the recommended measurements of the current measurement guidelines and offers detailed instructions on how to use the PCR measurement functions of the R&S DVM family.
01-Jun-2006 | AN-No. 7BM55
This application note describes how to generate test signals for 13.56 MHz RFID modules according to ISO 15693 with R&S Signal Generators and analyze them with R&S Signal Analyzers using software R&S WinIQSIM™.
17-May-2006 | AN-No. RSI01
CompactTSVP, monitoring systems, tire pressure, RF signal, microcontroller, ISM, wireless transmission Function Test of Tire Pressure Monitoring Systems Function Test of Tire Pressure Monitoring Systems CompactTSVP, monitoring systems, tire pressure, RF signal, microcontroller, ISM, wireless transmission Function Test of Tire Pressure Monitoring Systems Function Test of Tire Pressure Monitoring Systems