Using R&S®ELEKTRA Migration Tool
The R&S®ELEKTRA EMC test software is the successor of the R&S®EMC32 EMC measurement software. Like the R&S®EMC32 EMC measurement software, the R&S®ELEKTRA offers a solution that controls complete EMC systems and automates measurements on equipment under test (EUT) that is being tested for emissions (EMI) and immunity (EMS) compliance. It has more features and test types compared to R&S®EMC32.As both software platforms use different file formats, R&S®EMC32 users who upgrade their existing software to the R&S®ELEKTRA platform need to perform a file conversion before migrating their data to the R&S®ELEKTRA platform. This is done by using the R&S®ELEKTRA Migration Tool, which is installed automatically with each R&S®ELEKTRA installation.This Application Note describes how to use the R&S®ELEKTRA Migration Tool (version 4.4 onwards) for converting the backup data into the XML format that can be interpreted by the R&S®ELEKTRA software. It also provides recommended conversion steps (Chapter 5) and troubleshooting tips (Chapter 6). For instructions on migrating the data using R&S®ELEKTRA Migration Tool below version 4.4, refer to the R&S®ELEKTRA user manual. For better user experience, we recommend using the latest software version for migration.This Application Note does not describe the steps to backup data using the R&S®EMC32 or R&S®ES-SCAN software. For procedures on how to do so, refer to their respective manuals.
04-May-2023 | AN-No. 1SL396
3GPP TS25.141 defines conformance tests for W-CDMA base stations (including HSPA+ features). This application note describes how transmitter (Tx) tests (TS25.141 Chapter 6) can be performed quickly and easily by using signal and spectrum analyzers from Rohde & Schwarz. A few tests additionally require vector signal generators from Rohde & Schwarz. Example illustrates manual operation. A free software program enables and demonstrates remote operation. The W-CDMA base station receiver (Rx) tests (TS25.141 Chapter 7) are described in Application Note 1MA114.
21-Oct-2014 | AN-No. 1MA67
3GPP TS25.141 defines conformance tests for W-CDMA base stations (including HSPA+ features). This application note describes how all required receiver (Rx) tests (TS25.141 Chapter 7) can be performed easily and quickly by using vector signal generators and CW sources from Rohde & Schwarz. One test additionally requires a spectrum analyzer from Rohde & Schwarz.Example illustrates manual operation. A free software program enables and demonstrates remote operation. The W-CDMA base station transmitter (Tx) tests (TS25.141 Chapter 6) are described in Application Note 1MA67.
21-Oct-2014 | AN-No. 1MA114
Using option ZVR-B4 (Frequency Converting Measurements), a ZVR Vector Network Analyzer can be used for measurements on frequency converting devices such as mixers and amplifiers. Using the ZVR's ARBITRARY mode, the source and receiver frequency ranges of the ZVR's generator and receiver, plus for two external signal generators, can be defined independently. As a result, mixer and intermodulation products such as conversion loss or sampling mixers, can all be measured. Used together with option ZVR-B6 (Reference Channel Ports), group delay measurements can also be made on frequency converting devices.
19-Jan-1999 | AN-No. 1EZ47
Analysis, 5G FR1 MIMO signals, R&S®NRQ6, R&S®VSE Measurement of the phase difference between the MIMO layers is a challenging task in the design of 5G base stations. However, this measurement and its analysis can be easily accomplished using the R&S®NRQ6 frequency selective power sensor and R&S®VSE signal explorer software. Analysis of 5G FR1 MIMO signals with R&S®NRQ6 and R&S®VSE Analysis, 5G FR1
14-Jan-2022
During development of MU-MIMO antenna arrays, the beamforming algorithms undergo steady revision. Whether used in regression testing or verification of newly introduced features, fast beamforming verification helps to speed up R&D for beamforming antennas and improve performance of your product.
07-Jul-2020
Automated Solution with High Efficiency
5G New Radio (NR) presents dramatic challenges to the testing of User Equipment (UE) Power Amplifier (PA). Multiple frequency bands, flexible 5G operation mode, multiple PA performance metrics and the MIPI control interface increases the potential PA testing workload significantly. Manually repeating these tests under so many different scenarios can be costly and time consuming. An automated testing solution can help the test engineer to highly improve the testing efficiency.In this application note, it introduces an example of automated testing of 5G UE PA with R&S signal generator, signal and spectrum analyzer, vector signal explorer software, power meter along with power supply.The entire application note is organized with following structure:Chapter 2 outlines the challenges to 5G UE PA testing.Chapter 3 introduces the setup for 5G signal generation and analysis. For 5G signal generation, a batch program of converting *.CSV files with IQ vectors to ARB waveform files is introduced. For 5G signal analysis, the R&S®VSE software is recommended, which enables the separation of RF signal collection and measurement to improve testing efficiency.Chapter 4 provides the informative content about the integration of MIPI control interface for the PA ON/OFF state switching and register configuration.Chapter 5 gives a guide on the implementation of a quick power servo, in which the techniques to speed up the PA power level adjustment are discussed.Chapter 6 summarizes the automated testing procedure.
09-Aug-2021 | AN-No. 1SL365
New technologies and applications like 6G communications and sensing extend into sub-THz frequencies in the D band and beyond. New semiconductor technologies and processes need to be commercialized to support these efforts.
12-Dec-2023
Most of the tests specified in the 3GPP standard TS 34.121 [1] Release 6 (Rel-6) can be performed with the R&S®CMW500. This document provides a step-by-step guide on how to use a stand-alone R&S®CMW500 to take Rel-6 measurements on transmitter characteristics and execute performance tests according to TS 34.121 V9.7.0, clauses 5 and 10. Test cases that require fading simulation can also be carried out with the aid of a standalone R&S®CMW500 that has been configured with a built-in fading simulator option. That greatly reduces test setup complexity. Furthermore, the R&S®CMW500's wizard enables easy configuration of the test setup for various HSUPA subtests as specified by TS34.121 [1]. The procedure detailing how the wizard is used is also explained for each test case. The test cases mentioned in this application note are carried out using Rel-6 user equipment (UE) that supports Operating Band I and Power Class 3.
27-Nov-2013 | AN-No. 1CM97
Communication systems according to IS-136 (NADC) use Time Division Multiplex Access (TDMA) for the communication between base station and mobile stations. There are 6 time slots available. Depending on the amount of data, which have to be transmitted, the system uses full rate channels or half rate channels. A full rate channel means, that the mobile is accessed every 3rd time slot (e.g time slot 1 and 3, time slot 2 and 4 or time slot 3 and 6). With half rate channels the mobile is accessed every 6th time slot. Full rate and half rate channels may be mixed on demand. The base stations transmit continous on their frequency. Depending on the used combination of full rate and half rate channels the base station uses a different sequence of synchronisation words. The mobile stations use bursted transmission with one of the synchronisation words S1 to S6 defined in the standard. Signal Generator SME is excellently suited to generate these signals to test either base station receivers or mobile phone receivers. Together with the modulation data supplied with this application note the SME serves as a signal source for various test and measurement applications in the whole frequency range of IS-136 (NADC).
01-Jul-1999 | AN-No. 1GPAN35
Using R&S®RTP high-performance oscilloscopes and R&S®VSE-K6A phased array measurement option
12-Jul-2021
This application note describes the general setup and required equipment for EMC measurements according to the EMS standard IEC / EN 61000-4-6.
29-Mar-2007 | AN-No. 1SP31
Particle acceleration requires cavity resonators that are driven with high RF powers at defined frequencies. Rohde & Schwarz offers RF solid-state amplifiers for frequencies ranging from 9 kHz to 6 GHz, delivering CW power up to 80 kW.
27-Apr-2016
Leaving aside the microwave generators, the present line of Rohde & Schwarz products comprisessignal generators up to 1 GHz (SMX, SMG), up to 2 GHz (SMH, SMGU), up to 3 GHz (SME, SMT) and up to 4.3 GHz (SMHU). For applications at higher frequencies, all signal generators can also be operated with an external passive frequency doubler. This extends the range of possible applications up to 8.6 GHz. Some degraded specs regarding level and modulation are described below. For people using the frequency range 3 to 6 GHz, the low priced combination SMT plus frequency doubler will mainly be interesting. Signal generator SMHU is useful for the frequency range up to 8.6 GHz. Especially the phase noise performance is excellent with this instrument. the required output signal. It should also be pointed out that the residual FM and the SSB phase noise will be 6 dB poorer as a result of frequency doubling.
20-Apr-1998 | AN-No. 1GPAN03
Most of the tests specified in standard TS 34.121 for 3GPP Rel-99 can be performed with R&S®CMU200. This document provides a step by step guide on how to perform Rel-99 measurements on transmitter/receiver characteristics, and performance tests according to TS 34.121 V8.4.0 clauses 5, 6 and 7 with standalone R&S®CMU200. Test cases that require additional instuments e.g. fading simulator (R&S®SMU200A or R&S®AMU200A) or spectrum analyzer (R&S®FSQ) will be discussed in brief in this application note with recommended reference. A set of *.sav files based on R&SCMU200 firmware V5.02 for UE supporting band I with power class 3 in RMC 12.2 kbps downlink/uplink is attached to this application note.
15-Apr-2009 | AN-No. 1CM71
Most of the HSDPA tests specified in the TS 34.121 for 3GPP Release-5 / -7 and -8 can be performed with an R&S®CMW500. This document provides a step-by-step guide on how to use a stand-alone R&S®CMW500 to perform HSDPA Tests (from Rel.5 up to Rel.8 / DC-HSDPA+) measurements on transmitter characteristics and receiver characteristics in line with TS 34.121 V9.5.0, clauses 5 and 6. A set of save files based on R&S®CMW500 firmware V3.0.10 for user equipment supporting Operating Band I with Power Class 4 is attached to this application note for easy recall of important settings while performing tests in line with the relevant specifications.
17-Aug-2012 | AN-No. 1CM96
The R&S®RTO6 oscilloscope has an in-depth tool for debugging custom and commercial off-the-shelf serial buses for the avionics and aerospace industries.
20-Dec-2023
Most of the tests specified in standard TS 34.121 [1] for 3GPP Rel-6 can be performed with R&S®CMU200. This document provides a step by step guide on how to perform Rel-6 measurements on transmitter characteristics and performance tests according to TS 34.121 V8.7.0 clauses 5 and 10 with stand-alone R&S®CMU200. Test cases that require additional instruments, e.g. fading generator (R&S®SMU200A or R&S®AMU200A) will be discussed in brief in this application note with recommended reference. A set of *.sav files based on R&S®CMU200 firmware V5.03 for UE supporting operating band I and power class 3 in RMC 12.2 kbps + HSPA is attached to this application note.
07-Oct-2009 | AN-No. 1CM73
This application note shows how to configure, calibrate and perform conducted EMS (Electro Magnetic Susceptibility) measurements according to IEC / EN 61000-4-6 and EMI (Electro Magnetic Interference) measurements according to CISPR 16-2-1 with the R&S®EMC32 software tool.
19-Jul-2013 | AN-No. 1MA212
RF pulse measurements, to characterize the signal in the frequency domain, are traditionally carried out on an RF spectrum analyzer. For time related pulse parameters, oscilloscopes are widely used. However, the measurement capabilities of state of the art test and measurement equipment has evolved over time and crosses domains. With a combination of R&S®RTO digital oscilloscope and dedicated pulse analysis software R&S®VSE-K6, pulse signals can be analyzed in both domains, frequency and time.The R&S®RTO digital oscilloscopes are unique in that they allow output of I/Q data for processing. This application note focusses on signal measurement using this instrument.Analysis of an L-/S-band ATC RADAR utilizing the R&S®RTO2044 oscilloscope running Vector Signal Explorer Software R&S®VSE and Pulse Analysis personality R&S®VSE-K6 is followed by measurements on an X-band RADAR utilizing R&S®FSW, R&S®FPS, R&S®FSV or FSVA signal & spectrum analyzers with the same dedicated R&S®VSE-K6 software.
18-Oct-2016 | AN-No. 1MA249
Phase difference is the key parameter when characterizing direction finding (DF) scenarios. To analyze DF equipment, the phase difference needs to be determined before measuring other parameters such as the bearing. The R&S®VSE-K6A multichannel pulse analysis software in combination with a Rohde & Schwarz oscilloscope provides phase difference measurements even in challenging environments, utilizing the test equipment’s advanced trigger capabilities.
02-Mar-2021
FMCW radar sensors are used in vehicles for adaptive cruise control and for blind-spot, lane-change and cross traffic assistants. Radar sensors for acquisition of the surroundings are key components for future vehicles with semi-autonomous and fully autonomous driving. Autonomous driving requires radars that reliably detect objects in the surrounding area. Radar makes it possible to quickly and precisely measure the radial velocity, range and azimuth and elevation angle of multiple objects. For this reason, the automobile industry is increasingly using this technology in advanced driver assistance systems (ADAS). Rohde & Schwarz offers T&M solutions for generating, measuring and analyzing radar signals and components to ensure trouble free operation of these sensors. The high-performance oscilloscope R&S® RTP with four measurement channels is the perfect solution for multi-channel measurements on MIMO radar sensors and correlation with other signals e.g. power rails, whereas a spectrum analyzer such as the R&S® FSW85 offers highest dynamic up to 85 GHz.This application note focuses on how to measure and analyze FMCW radar signals with up to 6 GHz bandwidth with an R&S® RTP oscilloscope. On-board analysis features for pulse and chirp analysis for single- and multi-channel measurements will be addressed as well as the combination of oscilloscope and R&S® VSE software. Measurement of an FMCW radar signal in the 77 - 81GHz band with 4 GHz bandwidth is demonstrated.
07-Aug-2019 | AN-No. GFM318
3GPP TS36.141 defines conformance tests for EUTRA base stations (eNodeB). Release 14 added several tests, especially for enhanced License Assisted Access (eLAA).This application note describes how all required receiver (Rx) tests (TS36.141 Chapter 7) can be performed quickly and easily by using vector signal generators from Rohde & Schwarz. A few tests additionally require spectrum analyzers from Rohde & Schwarz.Examples illustrate the manual operation. A free software program enables and demonstrates remote operation.The LTE base station transmitter (Tx) tests (TS36.141 Chapter 6) are described in Application Note 1MA154.The LTE base station performance (Px) tests (TS36.141 Chapter 8) are described in Application Note 1MA162.
11-May-2016 | AN-No. 1MA195
Simulation can be a big time-saver when designing EMI filters for DC/DC converters. Power supply control chip vendors offer various filter design tools that provide reasonable design choices for filter simulation before any hardware prototype is available. However, simulated results can differ significantly for different tools if simulated models are not accurate or do not cover all the relevant components. Performing a hardware measurement to evaluate the effectiveness of a simulated EMI filter is therefore indispensable.
21-Sep-2021
3GPP TS36.141 defines conformance tests for EUTRA base stations (eNodeB). Release 14 (LTEAdvanced Pro) added several tests, such as those for enhanced Licensed Assisted Access (eLAA).This application note describes how all required performance tests (TS36.141 Chapter 8) can be performed quickly and easily by using vector signal generators from Rohde & Schwarz.Examples illustrate the manual operation. A free software program enables and demonstrates remote operation.The LTE base station transmitter (Tx) tests (TS36.141 Chapter 6) are described in Application Note 1MA154.The LTE base station receiver (Rx) tests (TS36.141 Chapter 7) are described in Application Note 1MA195.
11-May-2016 | AN-No. 1MA162
Rohde & Schwarz mobile network testing solutions enable operators to efficiently increase network capacity via hardware-related, capacity-enhancing features such as antenna tilt optimization, carrier aggregation, 4x4 MIMO and 6-sector sites.
09-Aug-2016
conducted conformance testing according to TS 38.141-1, Rel. 16
3GPP defines the Radio Frequency (RF) conformance test methods and requirements for 5G NR Base Stations (BS) in the technical specifications TS 38.141. This application note describes how all mandatory RF transmitter tests (TS 38.141-1, chapter 6), according to Release 16, can be performed quickly and conveniently with signal or spectrum analyzers from Rohde & Schwarz by either choosing manual operation or a remote control approach. Moreover, some test cases require additional signal generation equipment from Rohde & Schwarz.In Addition, a new Python software library comes with this application note to enable the remote control approach of base station testing. This example requires the RsInstrument module which can be found on pypi.org or installed via 'pip' and is provided as is.
27-Jan-2021 | AN-No. GFM313
Most of the tests specified in standard TS 34.121 for 3GPP Rel-99 can be performed with R&S®CMW500. This document provides a step by step guide on how to perform Rel-99 measurements on transmitter/receiver characteristics, and performance tests according to TS 34.121 V9.5.0 clauses 5 and 6 with standalone R&S®CMW500. A set of *.sav files based on R&SCMW500 firmware V2.1.20 for UE supporting band I with power class 3 in RMC 12.2 kbps downlink/uplink is attached to this application note.
16-Dec-2011 | AN-No. 1CM95
Comprehensive test solutions guide for production and R&D
Small cell is a compact base station with smaller form factor and lower transmission power in comparison to the conventional macro base station. It covers relatively small area and serves less users. Usually, small cell can be integrated into the existing mobile network. By the evolution of radio access technology, the role of small cell has been changing through the evolution path. In the 2G/3G time, its role was to provide coverage in corner cases. Later during LTE, networks are not just providing coverage but capacity too. Small cells were then used to provide the addition capacity where required without adding additional spectrum. Now in 5G era, network operators use densification as an important strategy to provide seamless 5G services which demand coverage, capacity and performance too. With use cases requiring the 5G millimeter wave (mmW) rollouts, it makes sense to use small cells for densification due to the propagation characteristics of mmW.In this application note, we will shed light on the testing aspects of a small cell throughout the product life cycle with particular focus on the production test solution for the small cell device under test (DUT) in FR2 (frequency range 2, mmW frequency band) in Over the Air (OTA) environment for option 6 split based on radio communication tester R&S®CMP200 and OTA chamber R&S®CMQ200. The document is complemented with more insights into test solutions used in typical R&D test applications towards the second half of the application note.
19-Jun-2023 | AN-No. 1SL395
The R&S®FSW signal and spectrum analyzer with the R&S®FSW-K160R realtime option and the R&S®FSW-K6 pulse measurement option is ideal for testing modern radars.
04-Jul-2013