  • EMC32-S: Immunity level not reached - abort EMS scan

    EMC32-S: Immunity level not reached - abort EMS scan Question EMC32-S: Is it possible to abort an EMS scan when the EMC32 goes below a certain immunity level, e.g. if the amplifier fails? Answer Yes, you can do that.  In the EMS Scan Template, on the Levelin...

    FAQ - Documents & Articles
  • EMC32-S: Pulse train support in EMC32

    EMC32-S: Pulse train support in EMC32 Question: I am using EMC32. How can I configure a test template with the SMB100A (including SMB-K27) or the SMF100A (including SMF-K27) to generate pulse trains for my EMC32 application? Answer: The pulse train software ...

    FAQ - Documents & Articles
  • FSx doesn't recognize active probe RT-ZS30

    FSx doesn't recognize active probe RT-ZS30 Question: We have an issue with our FSx and the RT-ZS30 probe: the FSx does not automatically recognize the probe Could you please help us to solve this blocking issue. Answer: You can work with the RT-ZS30 connec...

    FAQ - Documents & Articles
  • EMC32-S: Amplifier properties, reverse coupling path attenuation

    EMC32-S: Amplifier properties, reverse coupling path attenuation Question: In my hardware setup, I have two power meters connected to the amplifier, one for the amplifier FWD path and one for the amplifier REV path. When I look at the amplifier properties, I can only define the att...

    FAQ - Documents & Articles
  • Improve the calibration procedure for different setups

    Improve the calibration procedure for different setups Question: I have to perform a measurement with different settings (power, bandwidth, ...). If I use the microwave prober with an on-chip calibration substrate to perform a TOSM calibration, it would take a very long time becau...

    FAQ - Documents & Articles
  • How to connect HMExplorer to the instrument

    How to connect HMExplorer to the instrument Question: My HMExplorer does not connect to the instrument Error when adding a device. The interface could not be opened. Answer: The latest version of the HMExpl...

    FAQ - Documents & Articles
  • Changing virtual COM port to use field probe with EMC32

    Changing virtual COM port to use field probe with EMC32 Question: We are using EMC32 software for EMS measurements. Currently we have difficulties integrating a field probe. We cannot change the COM port of the field probe's USB/serial adapter and therefore cannot use the field pro...

    FAQ - Documents & Articles
  • Web interface allows several users to control the HMP

    Web interface allows several users to control the HMP Question: The HMP is used by two persons at the same time. One is using channel 1 and the other is using channel 2. Are they able to remotely control their channels at the same time via the web interface? ...

    FAQ - Documents & Articles
  • RF indicator while running an EMS test

    RF indicator while running an EMS test Question: I want to be sure that RF from the generator is switched off when my notification message is displayed. In EMC32, I see two RF indicators when the message is displayed. Which of the indicators shown in EMC32 is correct? ...

    FAQ - Documents & Articles
  • FSW: Check for SYNC error via remote control

    FSW: Check for SYNC error via remote control Question: I am using the 3GPP application. When the FSW is not synchronized to the signal, there is a big red bar with 'Sync failed' at the bottom of the display. How can I check for this via remote control? Answer...

    FAQ - Documents & Articles