Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
73 Results
Useful tips and tricks for your first measurement experience
Resistors, capacitors and inductors are the most basic components in electric circuits. It must be ensured that they work properly and accurately. Therefore, they need to be tested thoroughly during circuit design. This is usually done using LCR meters, which have become indispensable in the lab and in production. This application note looks at how to perform basic capacitor and inductor measurements accurately and reliably.
22-Feb-2024 | AN-No. 1GP142
Batteries are used in a variety of applications, and their quality can be affected by cycling. This tool provides an easy way to determine battery performance over time.
17-Dec-2021 | AN-No. 1GP130
The LCR meters R&S®LCX100 and R&S®LCX200 precisely measure the complex impedance and the resulting components values over a wide frequency range.
14-Mar-2022 | AN-No. 1GP132
Logging and charting tool for DC power supplies.
14-Nov-2019 | AN-No. 1GP122
This application note describes how to connect and configure DC power supplies R&S®NGL200 and R&S®NGM200 for synchronized on and off switching of all channels across multiple power supplies.
15-Jun-2020 | AN-No. 1GP126
This application note proposes a digital level shifter for connecting the I2S interfaces R&S®UPP-B2 and R&S®UPV-B41 to devices under test with a logic voltage different from 3.3 V.
27-Mar-2020 | AN-No. 1GA71
This application note applies to DC power supplies R&S®NGL200, R&S®NGM200, R&S®NGP800, R&S®NGU201 and R&S®NGU401, as well as LCR meters R&S®LCX100 and R&S®LCX200.
19-May-2022 | AN-No. 1GP135
This application note provides a tool which generates a voltage or current sweep using the arbitrary function of the instruments. A fast log captures voltage and current values during the sweep.
15-Feb-2021 | AN-No. 1GP129
remote control user interface for multiple DC power supplies
27-Aug-2020 | AN-No. 1GP127
Easy power sequencing and ripple noise analysis with MXO oscilloscopes
22-Apr-2024
Rohde & Schwarz supports O2 Telefónica in the Gigabit Innovation Track (GINT) Project with 5G network quality measurements
Measuring the power supply noise rejection (PSNR) requires accurate generation and leveling of artificial, sinusoidal disturbances and measurement of resulting phase-noise and jitter impairments.
30-Sep-2020
By making the simulation of fading scenarios easy and flexible, the R&S®SMW200A is the perfect tool to verify that your MIMO receiver can meet performance requirements.
27-Oct-2020
Discover the easy-to-use test solution for high speed multichannel acquisition for 5G NR signals from Rohde & Schwarz.
25-Feb-2020
This application note shows how to measure the phase accurately between several signals using vector network analyzers of the R&S®ZNA, R&S®ZNB and R&S®ZNBT families.
11-Jul-2019 | AN-No. 1EZ82
Binary transfer with remote instruments, like the KPI-1200 Series of remote instruments. Learn about the various methods of remote binary transfer, like the KPI-1200, X-20 Series and KPI-2100 Series of instruments in this article.
31-Mar-2022 | AN-No. 1SL381
Combining a low-noise oscilloscope with a power rail probe, developed uniquely for measuring power rails, provides a measurement system that delivers measurements that are more accurate.
09-Jul-2020
RF system noise contributions define receiver capabilities and sensitivity. The noise figure measures how the critical components affect the signal.
28-Jan-2022
Use R&S®RTP high-performance oscilloscopes and the R&S®VSE-K6A phased array measurement option for analyzing deceptive jamming techniques and automating jamer testing.
12-Jul-2021
Obtain fast data reading for realtime filter tuning with the R&S®ZNB vector network analyzer from Rohde & Schwarz.
27-Nov-2019
Define the exact current profile to minimize your electronics device´s power consumption with the R&S®NGM200 power supply series.
10-Dec-2020
The R&S®RTH-K38 user scripting software option makes the R&S®ScopeRider RTH handheld oscilloscope a powerful tool for maintenance and service applications.
06-May-2020
The R&S®ZNB measures the signal integrity on the PCB, taking the needed test fixtures and probes into consideration – a complete solution in a compact format.
25-Mar-2020
R&S®Server-Based Testing helps reduce test times for 5G New Radio multicarrier signals - each component carrier can be analyzed independently and in parallel.
13-Sep-2021
Fault identification in single elements of antenna arrays is possible by scanning in near-field range and applying the near-field to far-field transformation method.
24-Mar-2020
This application note describes a method using the R&S®ZNA analyzer family to measure group delay of mixers and frequency converters with an embedded local oscillator very accurately.
11-Jul-2019 | AN-No. 1EZ81
Load pull is a powerful method to characterize RF power amplifiers and enablse model extraction and validation and performance, ruggedness and efficiency testing.
02-Sep-2020
The R&S®ZNL is able to characterize a broad range of impedances with the lowest uncertainty among its competitors in the same class.
02-Oct-2019
In order to make it easier to monitor the use and status of instruments, some devices offer the software option Health and Utilization Monitoring Service (HUMS). HUMS provides all necessary information about the health status and utilization over time in many details.
11-Jan-2021 | AN-No. GFM336
Software tool for fast and repeatable optimization of signal analyzer RF front-end settings
The signal conditioning in the RF front-end of signal analyzers is crucial to achieve the best performance with respect to image-suppression, noise-floor, dynamic range and other RF-key parameters.Precise signal levelling is especially important for complex measurements like Error-Vector-Magnitude (EVM). To minimize the measurement uncertainty from test system contributions over a wide range of different levels, the RF front-end needs to be adapted continuously according to the signal characteristics, signal power and frequency - ideally using an automatic levelling algorithm.This document describes the approach of a waveform specific, on-site characterization of the signal analyzer: For each waveform and frequency of interest, the instrument is evaluated in a first step. With this additional data, a fast and repeatable auto-levelling can be performed during the actual measurement.
24-Jan-2022 | AN-No. 1EF111