Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
507 Results
Oscilloscope bus decoding, RTO2000, bus decoding, I2C Dive into your protocol to check for any problems with your I²C interface.
Perform interface tests during your USB design process and verify the compliance with USB test solutions from Rohde & Schwarz > Get more information!
Discover some of the key parameters of an oscilloscope and how they impact on the performance in this video series: Part 1: Bandwidth and frequency response R&S®RTO2000 Video, application videos, oscilloscope, troubleshooting, mixed signal oscilloscope R&S Talking about bandwidth Open Lightbox Talking about bandwidth
The R&S®RTO-K92 eMMC Compliance Test option offers an automated test solution for the electrical interface of an eMMC device according to the JEDEC specification, revision 5.1. Oscilloscope Application Videos, Application Video, Application Videos, Videos, eMMC Interface Compliance Test Learn how you can use the eMMC compliance test of R&S for automated testings of electrical interfaces!
RTO2000, debugging, EMI When debugging EMI problems in electronic circuits, development engineers face the challenging problem of quickly and accurately identifying and eliminating the sources of unwanted emissions. Many problems can be eliminated during development by using oscilloscopes for EMI debugging.
Oscilloscope bus triggering, RTO2000, bus triggering, history mode, break condition Use the hardware trigger to isolate break conditions. Break conditions can be corellated with their root cause one by one using the History Mode.
Discover direct hit solutions from Rohde & Schwarz for power conversion applications.
Compliance Testing, maximum output droop, RTO, Test Mode 6 A guide to carrying out a 100BASE-T1 compliance test for the MDI return loss using an R&S®ZND 2-port vector network analyser controlled by the ScopeSuite automation software.
Based on the new high-performance R&S®SMW200A vector signal generator and the R&S®RTO digital oscilloscope, the solution provides MIMO signal generation and realtime channel emulation (up to 4x4 or 8x2) as well as synchronous analysis of multiple TX antenna signals.
RTO2000, waveform display, R&S®SmartGrid, complex measurements Use the R&S®SmartGrid function to configure the display. For complex measurement tasks where several screen displays are helpful, you can superposition windows in multiple tabs. All measurement diagrams have labeled scales so you can immediately read important signal characteristics.
Oscilloscope bus debugging, RTO2000, bus debugging, UART, RS232, RS485 Let your Oscilloscope decode your UART/RS232/RS485 interfaces for you! So you can quickly understand the data and correlate the data content with the electrical signal.
Video, RTO2000, Oscilloscope, Power integrity test Today’s highly integrated electronic devices use smaller voltage levels and therefore require much smaller ripple levels on the power rails for reliable operation.
RTO2000, user interface, toolbar, display, cockpit The advanced user interface enables clear orientation thanks to colour coding, as well as having a high-resolution capacitive touchscreen with gesture support. The toolbar at the top of the screen provides access to frequently used functions such as measurements, zoom and FFT.
Webinar, RTO2000, Automotive Ethernet compliance testing This webinar presents details on the individual test cases of the compliance test and provides useful information on the required test setup.
RTO2000, toolbar, measurement functions, fast access The toolbar at the top of the screen provides access to frequently used functions such as measurements, zoom and FFT. Configure measurement in a few seconds by simply activating the measurement setup in the toolbar and choosing the desired measurement function and source channel in the sidebar.
For this video, we will be using a 2 GHz R&S®RTO oscilloscope, an 8 GHz R&S®ZND two-port VNA as well as the R&S®ScopeSuite automated test software. Webinar, Automotive, Ethernet This webinar will focus on 1000BASE-T1 automotive Ethernet compliance testing based on the Open Alliance (OA) TC8 specification for the physical layer.
The DUT operates in Test Mode 4 which is a PRBS sequence and it is exposed on a 125MHz disturber signal which comes out of theB6 signal generator which is integrated in the RTO6 oscilloscope. The ScopeSuite software provides a step by test foto guided test execution and reports the test results.
Introduction to Attribute Based Instrument Drivers
01-Dec-2012 | AN-No. 1MA170
The R&S®RTO Oscilloscope supports the acquisition and the detailed signal analysis of these signals by using the history mode. The history mode allows the user to look back to previous acquisitions and apply the wide set of analysis functions of the RTO.
03-Jun-2013 | AN-No. 1TD02
The radio unit activity versus power consumption is monitored using the R&S RTO oscilloscope to detect short power pulses or spikes. The results make it easy to evaluate energy efficiency measures such as advanced sleep modes and provide ratings for radio units based on their power consumption.
12-Nov-2020 | Press Release | Automotive
Rohde & Schwarz supports the UNH-IOL in Automotive Ethernet testing services for OPEN Alliance TC9 test specificationTest and measurement specialist Rohde & Schwarz extends its support to the University of New Hampshire Interoperability Laboratory (UNH-IOL) with an extension to their compliance test services. As a result, UNH-IOL customers can now achieve compliance for automotive Ethernet cables and connectors (link segment) based on the OPEN Alliance TC9 working group test specification supporting both unshielded (UTP) and shielded twisted pair cables and connectors (STP).
This application note introduces the working principles of a conventional trigger system and explains the advantages of the real-time capable digital trigger of the RTO oscilloscopes.
11-Apr-2012 | AN-No. 1ER04
Terrestrial air navigation systems provide safety critical service seamlessly. Learn more about constant performance monitoring & measurements for organizations.
Find out what it's like to launch a new product at Rohde & Schwarz! Our employees share their experiences.
This results in minimal trigger jitter without postprocessing correction as well as high sensitivity that can be extended up to 16 bit in HD mode. 16-bit, low noise, RTO2000, high definition, precise measurement The unique digital trigger system from Rohde & Schwarz uses the sampling point of the A/D converter in the acquisition path so that the trigger system's input data is identical to the displayed
R&S RT-Zxx High Bandwidth Probes - Specifications
This application note presents the Jitter analysis capabilities of the R&S®RTO for digital signals. It demonstrates the basic operation with an application example, and shows the associated jitter analysis.
29-Aug-2013 | AN-No. 1TD03
This application note explains the background of blind time and points out why a high acquisition rate is important. It furthermore explains the R&S RTO oscilloscope capabilities and how they help for faster debugging, measurement and analysis.
17-May-2011 | AN-No. 1ER02
Discover direct hit solutions from Rohde & Schwarz for embedded power efficiency testing applications.
Increase your knowledge with our webinars on automotive EMC and full-vehicle antenna testing covering topics from CISPR-25 to a practical approach to testing communication systems over the air and EMI debugging.