R&S®HL046E Antenna

High Gain Log-Periodic

  • Overview

Key Facts

The High Gain Log-Periodic Antenna R&S®HL046E offers excellent broadband characteristics, a radiation pattern that is approximately rotation-symmetrical as well as high gain, making it particularly suitable for EMS immunity measurements.

Features

  • High antenna gain, i.e. low amplifier power is required
  • No change of antennas needed over wide frequency range
  • Uniform object irradiation due to optimized radiation patterns

Specifications

Model Frequency range
R&S®HL046E 80 MHz to 3 GHz

Key Facts

  • 80 MHz to 3000 MHz
  • Log-periodic antenna for EMS measurements

    The High Gain Log-Periodic Antenna R&S®HL046E offers excellent broadband characteristics, a radiation pattern that is approximately rotation-symmetrical as well as high gain, making it particularly suitable for EMS immunity measurements.

    In comparison with existing systems, the required field strengths can be achieved with a lower amplifier power. This is due to the high antenna gain.

    Its small size, wide frequency range and folding mechanism make the antenna ideal for use in test chambers.

  • Recommended extras
    • Pneumatic Polarization Control R&S®HL046-P

Features & Benefits

  • High antenna gain, i.e. low amplifier power is required
  • No change of antennas needed over wide frequency range
  • Uniform object irradiation due to optimized radiation patterns
  • Small size
  • Influence of chamber reduced
  • Antenna gain approximately constant over the whole frequency range
  • Can be wall-mounted

Specifications

R&S®HL046E
Frequency range 80 MHz to 3 GHz
Polarization linear
Input impedance 50 Ω
VSWR
   <2500 MHz <2
   ≥2500 MHz <2.5
Practical gain typ. >8  dBi
Max. input power
   80 MHz 1400 W + 100 % AM
   500 MHz 600 W + 100 % AM
   1000 MHz 400 W + 100 % AM
   2000 MHz 300 W + 100 % AM
   3000 MHz 250 W + 100 % AM
Connector N female
Operating temperature range +5 °C to +40 °C in line with MIL-STD-810E
Class of application laboratory
Dimensions (W × H × L)
   Without tripod
     Folded approx. 0.85 m × 1.50 m × 1.81 m
     Open approx. 1.50 m × 1.50 m × 1.81 m
   With tripod
     Folded approx. 0.86 m × 1.90 m × 1.89 m
     Open approx. 1.50 m × 1.90 m (variable up to 2.60 m) × 1.89 m
Weight
   Without tripod approx. 17 kg
   Tripod approx. 12.5 kg
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Get a Quote

Please enter your inquiry.
Please enter your first name.
Please enter your name.
Please enter a valid email address.
Please enter your company name.
Please enter your city name.
Please enter your postal code.
Please enter your phone number.

Please enter your location.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

"I agree that ROHDE & SCHWARZ GmbH & Co. KG and
a) ROHDE & SCHWARZ Vertriebs-GmbH (for Germany) or  
b) the ROHDE & SCHWARZ entity in the imprint of this website (for any other country) 
may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity."

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the “Statement of Privacy“.

Please enter the characters shown in the image
show captcha
The input was not correct.
Do not enter data in this field
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Get a Demo

Please enter your inquiry.
Please enter your first name.
Please enter your name.
Please enter a valid email address.
Please enter your company name.
Please enter your city name.
Please enter your postal code.

Please enter your location.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

"I agree that ROHDE & SCHWARZ GmbH & Co. KG and
a) ROHDE & SCHWARZ Vertriebs-GmbH (for Germany) or  
b) the ROHDE & SCHWARZ entity in the imprint of this website (for any other country) 
may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity."

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the “Statement of Privacy“.

Please enter the characters shown in the image
show captcha
The input was not correct.
Do not enter data in this field
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Request information

Please enter your inquiry.
Please enter your first name.
Please enter your name.
Please enter a valid email address.
Please enter your company name.
Please enter your city name.
Please enter your postal code.

Please enter your location.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

"I agree that ROHDE & SCHWARZ GmbH & Co. KG and
a) ROHDE & SCHWARZ Vertriebs-GmbH (for Germany) or  
b) the ROHDE & SCHWARZ entity in the imprint of this website (for any other country) 
may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity."

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the “Statement of Privacy“.

Please enter the characters shown in the image
show captcha
The input was not correct.
Do not enter data in this field
International Website