Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
1103 Results
The antenna patterns of automotive radars provide a wealth of information that is of vital importance during radar development and validation.
28-Oct-2020
Verify and optimize your product design under realistic fading conditions in a deterministic lab environment that allows repeatable measurements using standardized and user-defined fading profiles.
27-Oct-2020
A radar system typically operates 24 hours with minimal downtime. Maintaining the operation of such a system requires fast identification of any defects in the system components. The R&S®ZNH handheld vector network analyzer helps field engineers quickly and reliably maintain radar systems to minimize downtimes.
22-Oct-2020
PAM-4 (4-level pulse amplitude modulation) has been introduced in high-speed serial data technology to reduce the bandwidth demands of ultra-high data rates. It uses only half the bandwidth per bit that would be required of conventional NRZ (non-return to zero) modulation. But at the same time, PAM-4 signaling complicates design and test at every turn. Evaluation of channels is now just as important to system development as serializer / deserializer (SerDes) testing and the challenges presented require a higher level of test and measurement performance than ever before. This paper investigates the evaluation complexities of PAM-4 interconnects at high data rates.
22-Oct-2020 | AN-No. GFM355
The R&S®FSW signal and spectrum analyzer measures and analyzes time sidelobes to optimize compressed radar signals as well as radar hardware components and systems. Developers of radar systems can improve and immediately validate their design using automated and reproducible measurements.
22-Oct-2020
Many serial interfaces use Manchester or non-return-to-zero (NRZ) coding. Oscilloscopes typically offer dedicated software options for debugging and testing the communications interfaces for common standards such as I2C, UART or CAN. The R&S®RTx-K50 option expands the addressable range of interface standards by adding decoding capability for standardized and proprietary Manchester or NRZ coded buses. It allows customizable configuration of the protocol structure that has to be decoded.
19-Oct-2020
For automated test applications, measurement time is often as important as the quality of the measurement. As with many situations, time is money. In practice, phase noise measurements are generally not considered fast, but test engineers still desire to save as much test time as possible. The Rohde & Schwarz®FSWP (FSWP) is a modern, digital signal processing based, phase-noise test set that performs many tasks in parallel in an effort to improve measurements speed. However, several measurement settings drastically affect measurement speed. This paper will discuss these settings and provide suggestions on improving overall measurement speed.The three key instrument parameters that affect FSWP measurement speed are:1. Number of cross correlations2. Resolution bandwidth (RBW)3. Offset frequency span
08-Oct-2020 | AN-No. GFM354
Timing components such as low jitter oscillators and clocks are necessary to facilitate increasing data rates in high speed digital designs. As part of the overall system design, the components also have to perform in the system’s non-ideal power integrity environment and limit the power supply induced phase noise and jitter from power rail disturbances. Measuring the power supply noise rejection (PSNR) requires accurate generation and leveling of artificial, sinusoidal disturbances and measurement of resulting phase-noise and jitter impairments.
30-Sep-2020
Almost every switched-mode power supply (SMPS) needs an EMI (Electro Magnetic Interference) input filter to suppress any disturbances of the SMPS on the power lines. This requirement having an input filter in the design ensures that no negative effect will occur in other parts of the systems connected to the power lines. Therefore, the design and the validation of the input filter is a major task during a typical power supply design. The conducted emission (CE) test according to a specific standard is a suitable and a common validation method to release the design at the end of the development cycle. Nowadays, this conducted emission test will be performed as pre-compliance test during the development phase in the lab as well. In this case, the designer will obtain an early feedback whether the design has to be optimized regarding any disturbances present on the power lines. In most cases, the designer has to adjust the input filter to obtain a more effective suppression of disturbances generated by the SMPS. However, the designer needs to know details about the noise spectrum to optimize the input filter as effective as possible. In addition to magnitude and frequency information of the noise source, it would be very helpful to know whether the noise is generated by a common mode source or by a differential mode source. During the standard conducted emission test, common and differential mode noise is a combination in the measurement results and thus not possible to gain deeper insights. This document will describe a method to separate common-mode and differential-mode separation using two oscilloscope channels. This separation approach works without any additional hardware component like a noise separator. The designer will be able to distinguish between common-mode (CM) and differential-mode (DM) noise. This additional information about the dominant mode provides the capability to optimize input filters very efficiently.
17-Sep-2020 | AN-No. GFM353
R&S®AdVISE is a visual inspection software to monitor different regions of interest (ROIs) in a video for visible and audible changes. It automates the process of visually monitoring equipment under test during a test sequence and therefore eliminates human inattention, ensures reproducible results and simplifies the test documentation. R&S®AdVISE offers the possibility to monitor up to 32 ROIs in one video with 12 different specialized ROI types for different kinds of events. That allows the user to apply R&S®AdVISE to all sorts of individual test setups.This application note explains how to setup R&S®AdVISE to monitor the temperature of an EUT by using an infrared camera.
14-Sep-2020 | AN-No. 1S008
Polychrome display method with the R&S®PR100, R&S®PR200, R&S®DDF007 and R&S®MNT100
09-Sep-2020
Power consumption analysis with the Rohde & Schwarz specialty DC power supplies app card Power consumption analysis with the Rohde & Schwarz specialty DC power supplies app card Power consumption analysis with the Rohde & Schwarz specialty DC power supplies Power consumption analysis with the Rohde & Schwarz specialty DC power supplies app card Power consumption analysis with the Rohde & Schwarz specialty
09-Sep-2020
Load pull is a powerful method for characterizing RF power amplifiers through impedance variation. Load pull enables model extraction and validation as well as performance, ruggedness and efficiency testing.
02-Sep-2020
Applications requiring higher voltages or currents, or a stack of voltage sources with taps in-between, demand the combination of several DC power supply channels in series or in parallel.All channels of DC power supplies R&S®NGL200 and R&S®NGM200 are isolated against the grounding equipment conductor and against the digital ground of the instrument. Therefore, channels can be connected in parallel for increasing the current capability, or in series for achieving higher voltages or dual-voltage supplies.When a large number of power supply channels is used, it is desirable to have a tool for configuring all instruments and channels from one user interface, and for keeping an overview over the states and measurement values from all channels.The application program of this application note provides such a tool. The document contains background information and user manual for the software.
27-Aug-2020 | AN-No. 1GP127
Testing radar warning equipment in realistic scenarios is crucial to reliable field performance. This typically involved dedicated instruments or test systems. Commercial vector signal generators (VSG) such as the R&S®SMW200A from Rohde & Schwarz have become a very attractive alternative thanks to their increased available bandwidth and processing power.
13-Aug-2020
Power converter and inverter designs for higher power levels are usually based on hard switching half bridge configurations. In such setups, users must pay particular attention to proper switching operations to prevent shoot-through events. Setting up complex real-time trigger conditions using the R&S®RTE and R&S®RTO oscilloscopes increases the test coverage and robustness of converter and inverter systems.
10-Aug-2020
This application note describes how to detect even small fails in dynamic turn indicators with R&S®AdVISE.
30-Jul-2020 | AN-No. 1S006
Vector Network Analyzers of t ZNA and ZNB family are able to measure magnitude and phase of complex S-parameters of a device under test (DUT) in the frequency domain. By means of the inverse Fourier transform the measurement results can be transformed to the time domain. Thus, the impulse or step response of the DUT is obtained, which gives an especially clear form of representation of its characteristics. For instance, faults in cables can thus be directly localized. Moreover, special time domain filters, so-called gates, are used to suppress unwanted signal components such as multireflections. The measured data "gated" in the time domain are then transformed back to the frequency domain and an Sparameter representation without the unwanted signal components is obtained as a function of frequency. As usual, other complex or scalar parameters such as impedance or attenuation can then be calculated and displayed.
30-Jul-2020 | AN-No. 1EP83
This application note shows how to configure the R&S®AdVISE visual inspection software to automate the immunity testing in line with EN 55020 and CISPR 35 on TV sets and monitors.
30-Jul-2020 | AN-No. 1S007
The R&S®ELEKTRA EMC test software is a solution that controls complete EMC systems and automates measurements on equipment under test that is being tested for emissions and immunity compliance. It can be used to remotely control R&S®AdVISE, which is a visual inspection software to monitor up to 32 different Regions of Interest in one video for visible and audible changeThis Application Note describes how to set up R&S®ELEKTRA and R&S®AdVISE for remote testing.
23-Jul-2020 | AN-No. 1S005
The R&S®SMW-K546 software option aids the optimum design of multiple path amplifiers, including Doherty Amplifiers.This application note provides guidance on the use of the software option, both for direct control and programming via the touchscreen, and for remote control using SCPI.The software and associated techniques may similarly be used to develop other quasi-linear, multi-path amplifiers; including Balanced, Anti-Phase (so-called Push-Pull), Distributed, Spatially Combined, Load Modulated Balanced and many more.
13-Jul-2020 | AN-No. GFM345
Make more accurate power rail measurements.
09-Jul-2020
During development of MU-MIMO antenna arrays, the beamforming algorithms undergo steady revision. Whether used in regression testing or verification of newly introduced features, fast beamforming verification helps to speed up R&D for beamforming antennas and improve performance of your product.
07-Jul-2020
Today’s cars are highly integrated and interconnected. Up to 150 embedded electronic control units (ECUs) in a car secure a convenient and safe driving experience. Examples of ECUs include transmission control modules, ECUs for air conditioning systems, and even self-updating 5G-ready telematics control units.
06-Jul-2020
radiated conformance testing according to TS 38.141-2, Rel. 16
3GPP defines the Radio Frequency (RF) conformance test methods and requirements for 5G NR Base Stations (BS) in the technical specifications TS 38.141. This application note describes all mandatory RF receiver tests (TS 38.141-2, chapter 7), according to Release 16.Furthermore, this document provides a brief introduction about the different R&S OTA antenna test solutions and how they are applicable for base station conformance testing. Rohde & Schwarz offers suitable solutions for any test case that is mentioned in this application note.
30-Jun-2020 | AN-No. GFM325
5G New Radio (NR) FR1 MIMO or beamforming downlink signal analysis especially the phase measurement of each MIMO layer and the determination of the phase difference between the MIMO layers are essential for the 5G base station product design.In this application note, it describes two test solutions from R&S® to cope with the 5G FR1 downlink MIMO signal analysis challenges either using R&S®RTP/RTO oscilloscope or R&S®NRQ6 frequency selective power sensor as RF frontend to capture the signal and together with R&S®VSE as post-processing tool for the IQ analysis.The aim of this application note is to walk the user through the necessary steps on both test solutions to enable the 5G FR1 downlink MIMO signal analysis.It is assumed that the reader has certain pre-knowledge of 5G NR physical layer. In case a refreshment is needed, please refer to the for further reading.
26-Jun-2020 | AN-No. GFM343
Measurements of very high noise figure components are performed for a number of reasons. For instance, in a wide range of applications, devices under test (DUT) are characterized within a complex test setup that includes high losses before or after the low noise DUT. In case of high frequencies, the switch matrix with complex signal routing and cables might have a very high loss. In other cases, the device might be embedded in a test setup where direct access is physically impossible, on-wafer probing is one example for this case. Using conventional measurement equipment, the noise figure measurement of such a device is very unstable if not impossible at all.
24-Jun-2020 | AN-No. 1EF110
This application note describes how to use the generic interface in R&S®AdVISE for remote operation.
19-Jun-2020 | AN-No. 1S002
The R&S®FSW offers a variety of different bandwidth options and makes it possible to combine these with external harmonic mixers to enlarge the analyzer’s frequency range up to 325 GHz. This application card will give some guidance as to the possible combinations of bandwidth options and mixers in conjunction with the needed IF frequencies.
16-Jun-2020
All channels of DC power supplies R&S®NGL200 and R&S®NGM200 are isolated against the grounding equipment conductor and against the digital ground of the instrument. Therefore, channels can be connected in parallel for increasing the current capability, or in series for achieving higher voltages or dual-voltage supplies. In the case of parallel and serial connections it is usually desired to switch all channels simultaneously on and off for protecting the supplied circuitry and for avoiding overcurrent on other power supply channels.This application note describes how to connect and configure DC power supplies R&S®NGL200 and R&S®NGM200 for synchronized on and off switching of all channels across multiple power supplies.
15-Jun-2020 | AN-No. 1GP126