Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
735 Results
It is frequently desired to process the results stored on the floppy on a PC, eg for the generation of customer-specific test reports by means of a word processing system. To enable processing on an external PC, the binary data usually need conversion into an ASCII format. This is possible by means of the ESXS2ASC.EXE program. The program is available free of charge from your Rohde & Schwarz representative.
18-Jan-2002 | AN-No. 1EE21
This application note shows how to determine the quality of a video streamed by an LTE mobile with R&S®CMW500 Radio Communication Tester and R&S®VTE Video Analyzer. The R&S®CMWrun Test Software with CMW-KT051 General Purpose and CMW-KT105 AV Difference Analysis option allows the user to easily automate these tests.
08-Sep-2014 | AN-No. 1MA253
A major US East Coast broadcast network was looking for a solution that would enable them to orchestrate multiple business units to handle the increased demand to deliver content with a very fast turnaround.
18-Nov-2014
Broadcasting transmitters are subject to particularly stringent standards with respect to broadcast signal quality, because even small faults can lead to service disruptions for many viewers. A single instrument, the R&S®ETL TV analyzer, performs all required DVB-T / DVB-H transmitter measurements, from the initial acceptance testing for the transmitter, to measurements performed during commissioning and preventive maintenance.
13-May-2013 | AN-No. 7BM101
1SP01 Production Produktionstestsysteme- Funktionstest von Businesstelefonen Produktionstestsysteme- Funktionstest von Businesstelefonen 1SP01 Production Produktionstestsysteme- Funktionstest von Businesstelefonen Related products
08-Apr-2002 | AN-No. 1SP01
Version 1.3.1 of the DVB-T2 standard ETSI 302 755 introduced the T2-Lite profile to ease the implementation of mobile TV services. This was achieved by minimizing the complexity of the required receiver and allowing side-by-side integration into existing conventional (T2-Base) DVB-T2 channels. For the purposes of testing the compatibility and performance of receiver modules, this application note describes how this type of composite T2-Base/T2-Lite RF signal can be simulated using one R&S®BTC or alternatively two instruments from the family of broadcast signal generators comprised of the R&S®SFU, R&S®SFE, R&S®SFE100 and R&S®SFC. Only one corresponding multiple profile T2-MI stream is required, either in the form of a file or via an external gateway.
03-Feb-2014 | AN-No. 7BM81
This Application Note describes the differences in intermodulation distortion measurements between traditional spectrum analyzers with analog narrow-band IF signal path and modern spectrum analyzers using a wide-band IF signal path and digital RBW filters.
02-Jul-2012 | AN-No. 1EF79
The Radiocommunication Tester CRTx can be used to test various aspects of GSM based mobile telephones. For this, a large number of testcases written in accordance with the GSM Rec. 11.10-1 are available. These tests are written in Borland C programming language, are supplied as source code, may also be modified by the user and are normally performed manually.
07-Mar-2002 | AN-No. 1CMAN30E
- not available -
20-Jul-2001 | AN-No. 7BM21
The R&S EX-IQ-Box serves as a digital baseband interface between a device under test (DUT) and Rohde & Schwarz generators, analyzers and radio communication testers. The DigIConf software supplied with the device controls up to four R&S EX-IQ-Boxes in a test setup and can thus output IQ data for feeding into a DUT while simultaneously receiving IQ output from a DUT.To work together smoothly, the DUT, the R&S EX-IQ-Box and the R&S test instruments have to be configured properly. The purpose of Application Note 1MA168 is to introduce the right 'initial steps' required to get started successfully.
23-May-2012 | AN-No. 1MA168
This application note describes how to configure a Rohde & Schwarz Network Analyzer to make spectral measurements directly on a device under test.
16-Mar-2012 | AN-No. 1EZ62
Emergency Call (eCall) is a service provided in Europe with the goal of reducing response times for accidents or other emergencies on the roadways. This application note briefly describes the technology behind eCall and presents conformance tests for eCall using the R&S®CMW500 RF tester and the R&S®SMBV100A vector signal generator. A Test software for eCall makes it quick and easy to perform these tests with the GSM or WCDMA wireless communications standard. It also shows a test solution for GNSS performance tests for eCall using the R&S®SMBV100A vector signal generator and the option R&S®SMBV-K361 together with CMWrun.This application note is outdated. We therefore refer to the newer application note .
24-Jan-2018 | AN-No. 1MA241
This application note describes how to connect and use the highly popular R&S®NRP-Z family of USB SMART power sensors with the Android application (app): R&S®Power Viewer Mobile for mobile devices running on Android 4.0 operating systems. Multi-path diode and wideband power sensors as well as thermal R&S®NRP-Z sensors are supported. The app "R&S®Power Viewer Mobile" is available on .
04-Jun-2013 | AN-No. 1MA215
This application note describes an effective method for generating test setups, performing measurements and producing test reports with the hand-held Spectrum Analyzer R&S FSH3
31-Jan-2003 | AN-No. 1EF50
A simple concept with Azure IoT
Cloud development, microservice architectures and container virtualization are becoming more and more standard. Software components are repacked into containers, networked with each other and then brought into the cloud. The topic is also becoming increasingly interesting for test & measurement.But how do you connect your existing measurement equipment to the cloud, with instruments in some cases not even having an internet connection?This document describes an approach how to establish a remote connection between the instrument and the cloud using an IoT broker. The implementation is done using an Azure IoT Hub and software in .NET Core.
15-Dec-2020 | AN-No. GFM319
This program applies to SFQs which are equipped with the first generation of noise generators (Var 02) and with FW version 1.24 or higher. [[ br /> One of the most important measurements of DVB systems concern noise margins. The C/N signal produced by the SFQ needs to be as accurate as possible. [[ br /> The present application note is intended to this purpose, with a special calibration process.
20-Jul-2001 | AN-No. 7BM08
This application note discusses WLAN standard IEEE 802.11n. It first describes the most important amendments to previous releases and the ambitious new measurement tasks. Then, it describes how to deal with these tasks using Rohde & Schwarz instruments. The main focus here is on transmission over several TX and RX antennas (MIMO). Building multistandard signals using Rohde & Schwarz generators is also described. Screenshots from the analyzer taken on 802.11n signals complete the document.
26-Apr-2013 | AN-No. 1MA179
The duration of a measurement in multi evaluation list mode is sensitive to the test setup. This document describes various methods to achieve optimized performance for such measurements. The availability of the methods depends on the CMW500 version.
17-Jul-2012 | AN-No. 1CM100
This application note describes how to configure the signal source analyzer R&S FSUP for highest dynamic range phase noise measurement in the microwave frequency range up to 50 GHz. It compares performance in terms of phase noise sensitivity using an additional internal down converter versus an external down converter or a frequency divider. Both methods are described and differences are shown.
18-Feb-2009 | AN-No. 1EF68
The MHL standard specifies the transmission of high-definition audio and video data on five individual lines, as well as the exchange of bidirectional control information and the supply of power from the sink to the source. Over 200 million portable CE devices - such as mobile phones, tablet PCs and cameras - already use this interface to present content onto larger screens. To ensure functionality and interoperability, every new MHL-capable device must, before entering the market, undergo thorough tests at an authorized test center (ATC) in line with the compliance test specification (CTS) issued by the MHL Consortium. This application note provides an overview of the MHL technology and also describes the Rohde & Schwarz compliance test solution for the system part of the current MHL2.0 standard version.
14-May-2013 | AN-No. 7BM83
3GPP TS25.141 defines conformance tests for UTRA base stations (NodeB). This application note describes how performance tests (TS25.141 Chapter 8) can be performed quickly and easily by using vector signal generators from Rohde & Schwarz. Examples illustrate the manual operation. A free software program enables and demonstrates remote operation.
04-Mar-2015 | AN-No. 1MA78
Especially with test receivers not comprising a built-in disk drive (ESHS10, ESVS10, ESVD, ESVB and ESPC) it is necessary to store instrument settings before a firmware update or before changing the battery of the static memory to be able to restore the settings later on. Frequently it is desirable to exchange settings or comprehensive data like transducer sets between receivers, or receivers have to be set up to suit different applications.
18-Jan-2002 | AN-No. 1EE20
This white paper describes the interaction between intermodulation products generated by a device under test (DUT) and intermodulation products generated internally in a spectrum analyzer. The overall intermodulation distortion may be too optimistic or pessimistic. Examples demonstrating cancelling IM products and necessary steps to avoid an influence of the spectrum analyzer on the measurement results are outlined.
29-Nov-2012 | AN-No. 1MA219
Due to today’s worldwide highly competitive communications market, achieving shorter product design cycles, quicker response to customer requests and high-volume product runs at low costs is vital for manufacturers of wireless devices and components. These requirements inevitably lead to demands for improving the throughput of Automated Test Equipment (ATE) by increasing its speed. This application note describes in detail how the special features of the R&S® SMATE200A can be used to optimize speed and throughput in an automated test environment.
17-Apr-2007 | AN-No. 1GP63
Broadcasting transmitters are subject to particularly stringent standards with respect to broadcast signal quality, because even small faults can lead to service disruptions for many listeners. A single instrument, the R&S®ETL TV analyzer, performs all required DAB transmitter measurements, from the initial acceptance testing for the transmitter, to measurements performed during commissioning and preventive maintenance.
24-Jul-2013 | AN-No. 7BM104
This application note is a programming guide. It briefly summarizes basic tips and information about SCPI programming for remote-controlling Rohde & Schwarz signal generators.
26-Apr-2013 | AN-No. 1GP79
1TD04 1TD04, DC/DC, Oscilloscopes The objective of this paper is to evaluate the performance of a power supply using an oscilloscope. The main measurements taken are the input frequency, output voltage, output current, and the switching frequency. Initial Evaluation of a DC/DC Switch Mode Power Supply 1TD04 1TD04, DC/DC, Oscilloscopes The objective of this paper is to evaluate the performance of a
26-Nov-2013 | AN-No. 1TD04
Performing a multi-port calibration of a vector network analyzer (VNA) is straight forward by using either a calibration unit with the corresponding numbers of ports or single calibration standards. This paper shows how to perform a n-port multi-port calibration by using calibration unit with a lower number of ports than available of the vector network analyzer.
06-Feb-2013 | AN-No. 1EZ70
The R&S® IQ File Cutter can load IQ data from supported IQ file formats and export part of the signal to another file. This is helpful when dealing with long measurement recordings, of which only parts are of interest and should be extracted for further analysis.
11-May-2020 | AN-No. GFM338