R&S®ZN-Z15x network analyzer calibration units

With 2, 4 or 6 ports fixed, or up to 24 ports configurable

R&S®ZN-Z15x network analyzer calibration units
Open Lightbox
R&S®ZN-Z15x network analyzer calibration units
Open Lightbox
R&S®ZN-Z15x network analyzer calibration units
Open Lightbox
R&S®ZN-Z15x network analyzer calibration units
Open Lightbox
R&S®ZN-Z15x network analyzer calibration units
Open Lightbox
R&S®ZN-Z15x network analyzer calibration units
Open Lightbox
R&S®ZN-Z15x network analyzer calibration units
Open Lightbox
R&S®ZN-Z15x network analyzer calibration units
Open Lightbox
R&S®ZN-Z15x network analyzer calibration units
Open Lightbox
R&S®ZN-Z15x network analyzer calibration units
Open Lightbox
R&S®ZN-Z15x network analyzer calibration units
Open Lightbox
R&S®ZN-Z15x network analyzer calibration units
Open Lightbox
R&S®ZN-Z15x network analyzer calibration units, economy, Front High R&S®ZN-Z15x network analyzer calibration units, economy, Side view R&S®ZN-Z15x network analyzer calibration units, economy, Front view R&S®ZN-Z15x network analyzer calibration units, economy, Front view R&S®ZN-Z15x network analyzer calibration units, economy, Side view R&S®ZN-Z15x network analyzer calibration units, economy, Side view R&S®ZN-Z15x network analyzer calibration units, economy, Back view R&S®ZN-Z15x network analyzer calibration units, economy, Side view R&S®ZN-Z15x network analyzer calibration units, economy, Back view R&S®ZN-Z15x network analyzer calibration units, economy, Side view R&S®ZN-Z15x network analyzer calibration units, economy, Front Low R&S®ZN-Z15x network analyzer calibration units, economy, Front view

Key facts

  • Automatic calibration units with 2, 4 or 6 ports, 8.5 GHz
  • R&S®ZN-Z154 multiport calibration unit configurable with up to 24 ports
  • Easy calibration of multiport setups of up to 24 ports without multiple reconnections
  • R&S®ZN-Z156 2-port calibration unit up to 67 GHz

Smart calibration equipment tailored to your DUT

1 port to 24 ports calibrated - flexibly and conveniently

The R&S®ZN-Z15x calibration units make error-prone and time-consuming calibration procedures a thing of the past. Connect all the test cables once, use auto-detection and calibrate up to 24 ports at the stroke of a key. Even multiport systems (R&S®ZNB plus switch matrices or the R&S®ZNBT multiport units) are quickly and reliably calibrated. When using different Calibration Units for different applications, you can expect full flexibility: even a 2-port unit can calibrate any port number. 

  • Units with 2, 4 and 6 ports (fixed) up to 8.5 GHz, SMA (f) - Type N, 2 port, 8.5 GHz.
  • R&S®ZN-Z154 configurable for 6, 12, 18, 24 ports, 8.5 GHz, SMA(f)
  • R&S®ZN-Z156 with 2 ports 1.85 mm(f), 67 GHz   
  • Auto-configuration, user characterization supported

Features & benefits

Wide range of port numbers

Units with 2, 4, 6, 12, 18, 24 ports tailored to your application

Connect all cables at once (no repeat connection required) to the port numbers corresponding to your DUT port count and start calibrating with a keystroke.

Flexible configuration and use

Calibrate all port counts with every unit

It is no problem to calibrate more ports than the R&S®ZN-Z15x offers. A step-by-step guide helps users calibrate every port number using a 2-port calibration unit, resulting in full n-port calibration.

User recharacterization

Get your R&S®ZN-Z15x ready for special test port connector type combinations

If standard connector types are not suitable for your setup, the R&S®ZNB/ZVA/ZNA FW allows recharacterization of your CalU: Connect an adapter to the CalU for characterizing the combination, making the adapter part of the CalU (requires a VNA calibrated with the desired connector types).

Auto configuration and detection

Plug and play calibration

The R&S®ZN-Z15x calibration units are automatically detected via the USB connection. All required data is transferred to the VNA. When starting the calibration, the connected test cables and port assignment can be found with a keystroke. The calibration can be launched with minimum effort, time and highest reliability.

Available models

Available models
Models
Type
Frequency range
Connector type
Number of ports
Description

R&S®ZN-Z152

Order number 1319.6003.36

Type
Calibration unit
Frequency range
100 kHz to 8.5 GHz
Connector type
SMA (f)
Number of ports
6 ports
Description
-

R&S®ZN-Z153

Order number 1319.6178.34

Type
Calibration unit
Frequency range
100 kHz to 8.5 GHz
Connector type
SMA (f)
Number of ports
4 ports
Description
-

R&S®ZN-Z154

Order number 1319.5120.02

Type
Calibration unit
Frequency range
100 kHz to 8.5 GHz
Connector type
SMA (f)
Number of ports
6 ports
Description
Number of ports can be increased to up to 24 with Options R&S®ZNZ154-B22, R&S®ZNZ154-B32 and R&S®ZNZ154-B42.

R&S®ZN-Z156

Order number 1332.7239.03

Type
Calibration unit
Frequency range
10 MHz to 67 GHz
Connector type
1.85 mm (f)
Number of ports
2 ports
Description

Available options

General
Product
Description
R&S®ZNZ154-B22

Order number 1319.5136.22

Description

Additional port 7 to 12

(only with R&S®ZN-Z154 Calibration Unit)

R&S®ZNZ154-B32

Order number 1319.5136.32

Description

Additional port 13 to 18

(only with R&S®ZNZ154-B22)

R&S®ZNZ154-B42

Order number 1319.5136.42

Description

Additional port 19 to 24

(only with R&S®ZNZ154-B32)

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.