Key facts

  • Power measurement range: 50 µW to 12 kW
  • Frequency bandwidth: DC to 100 kHz
  • Sampling rate: 500 ksample/s
  • Supports three switchable crest factors
  • Latest R&S design featuring in-device graphical analysis and compliance evaluation

Starting at €1.620

  • R&S®Essentials

All-in-one  

the compact class, that has it all

The R&S®NPA series of single phase power analyzers comprises a comprehensive range of compact testers meticulously designed for AC/DC load or standby current characterization, boasting a fundamental accuracy of 0.05% and low current measurement capability down to 5 milliamps. Setting itself apart from competitors in the market, these analyzers:

  • Require no additional tools for graphical analysis and compliance testing.
  • Provide numerical displays of 26 critical parameters.
  • Feature an auto-range function, enhancing testing efficiency.
  • Offer a fast display update rate of 100 milliseconds, enabling engineers to achieve short tact times.
  • Incorporate frequency and adaptive filter capabilities to eliminate unnecessary noise and ensure smooth and accurate results.
The R&S®NPA seamlessly integrates all essential and remote control functionalities necessary for research and development, production line, and quality assurance testing of electric devices.

Features & benefits

Compliance in-device testing

Evaluation functions according to IEC 62301, EN 50564, or EN 61000-3-2


 

All tests conducted with our compliance testers adhere strictly to the following standards:

  • IEC62301: Standby power consumption
  • EN50564: Standby power consumption
  • EN61000-3-2: Harmonic currents for EMC, CE approval
A user-friendly step-by-step wizard will assist users throughout the measurement process, automatically configuring the necessary instrument parameters. This approach minimizes potential measurement errors and ensures rapid access to results. No prior familiarity with the aforementioned standards is required. Upon completion of testing, the system generates verification reports, eliminating the necessity for an external PC

Typical test setup with R&S®NPA-Z1 socket adapter
Open Lightbox

Typical test setup with R&S®NPA-Z1 socket adapter

Inrush measurement

Graphical view over one waveform period

Utilize a graphical representation to depict occurrences such as fast switch-on operation. This approach simplifies comprehension and facilitates the comparison between the switching on and the steady-state operation of the device. The system enables continuous recording of 8192 samples, accommodating recording durations spanning from 16 milliseconds to 67 seconds. Following a trigger event, akin to executing a single-shot capture on an oscilloscope, voltage and/or current are graphically plotted.

Inrush view showing the switch-on operations
Open Lightbox

Inrush view showing the switch-on operations

Trend chart function

Graphical display versus time

This graphical mode facilitates the plotting of up to two measured variables against time, similar to the roll mode feature found in oscilloscopes. Primarily employed for observing more extended timeframes, it accommodates data ranging from 40 seconds to 80 minutes on the display. Users can decide the variables for plotting and adjust the timebase, while the vertical trace scaling is managed automatically. During operation, the numerical representation of maximum and minimum values is provided on the screen for enhanced analysis

Simultaneous display of voltage and current versus time
Open Lightbox

Simultaneous display of voltage and current versus time

Waveform function

Oscillographic waveform chart

This function facilitates a graphical representation of voltage, current, and/or power across a single waveform period, akin to the display format on an oscilloscope. The period is automatically determined by the power analyzer R&S®NPA. An automatic hardware trigger initiates each acquisition, and the waveform is continuously refreshed. Alongside waveform visualization, the R&S®NPA furnishes numerical outputs for RMS voltage, RMS current, and power, with softkeys enabling the selection of displayed or concealed traces

Simultaneous display of voltage, current and power for one period
Open Lightbox

Simultaneous display of voltage, current and power for one period

Harmonic analysis

Harmonics as bar chart or table view

Harmonic mode enables the computation of Root Mean Square (RMS) values and phase angles for harmonics. The accompanying bar chart elegantly visualizes patterns for up to 50 harmonics of voltage and/or current, while the tabular presentation offers comprehensive insights into magnitude and phase values per harmonic. Additionally, users have the flexibility to selectively display odd or even harmonics. The intuitive interface allows seamless navigation through the data, with cursors or a rotary knob enabling users to focus on individual harmonics, highlighted in a distinctive yellow hue.

Harmonics visualized as bar chart
Open Lightbox

Harmonics visualized as bar chart

Energy consumption meter

Real-time integrator

The integrator function serves a specialized purpose in the context of unstable power measurements. It is designed to compute and present the cumulative power or energy consumption of a DUT across a designated time span during both active and standby states. Users retain the flexibility to select their preferred acquisition mode, choosing between manual, time-based, or event-based options. All models of R&S®NPA deliver results in various formats, including positive, negative, and total watt-hours, with continuous updates in real time.

Integrator mode selection
Open Lightbox

Integrator mode selection

Available models

Available models
Models
Description
Frequency range
Power measurement range
Measurement functions
Starting at

R&S®NPA101

Order number 3657.0562.02

Description
Power meter
 
Frequency range
DC to 100 kHz
 
Power measurement range
50 µW - 12 kW
Measurement functions
Basic
Starting at
€1.620

R&S®NPA501

Order number 3657.0562.03

Description
Power analyzer
 
Frequency range
DC to 100 kHz
 
Power measurement range
50 µW - 12 kW
Measurement functions
Basic, advanced, graphical
Starting at
€2.910

R&S®NPA701

Order number 3657.0562.04

Description
Compliance tester
 
Frequency range
DC to 100 kHz

 
Power measurement range
50 µW - 12 kW
Measurement functions
Basic, advanced, graphical, in-device compliance evaluation
Starting at
€3.470

R&S®NPA501-G

Order number 3657.0562.05

Description
Power analyzer, inc. IEEE-488 (GPIB)

 
Frequency range
DC to 100 kHz
 
Power measurement range
50 µW - 12 kW
Measurement functions
Basic, advanced, graphical
Starting at
€3.360

R&S®NPA701-G

Order number 3657.0562.06

Description
Compliance tester, inc. IEEE-488 (GPIB)
 
Frequency range
DC to 100 kHz
 
Power measurement range
50 µW - 12 kW
Measurement functions
Basic, advanced, graphical, in-device compliance evaluation
Starting at
€3.920
Specifications
Electrical specifications
Analog bandwidth DC to 100 kHz
Frequency accuracy 0.1 % of reading
Basic accuracy 0.05 % of reading
Sampling frequency 500 kHz
Input impedance 2 MΩ
Current measurement range  1 mA to 20 A 
Voltage measurement range  1 mV to 600 V 
Power measurement range  dependent on combination of voltage and current ranges  50 µW to 12 kW
Display and interfaces
Display resolution 5 digits, 10 updates/s
Remote control interfaces: standard all models USB-TMC, USB-CDC (virtual COM), LAN
Remote control interfaces: optional R&S®NPA501-G, R&S®NPA701-G IEEE-488 (GPIB)
Display 320 × 240 pixel (QVGA-color)
Special functions
Basic  all models active power, apparent power, reactive power, lambda power factor, phase shift, frequency, voltage (RMS and average), current (RMS and average), total harmonic distortion, energy, data logging
Graphical  R&S®NPA501(-G), R&S®NPA701(-G) trend chart mode, inrush mode, harmonics mode, waveform mode
Advanced  R&S®NPA501(-G), R&S®NPA701(-G) limit testing, input for external probe and shunt, analog input and output, digital input and output, minimum & maximum voltage, current, and power
Compliance evaluation R&S®NPA701(-G) Standards: IEC62301, EN 50564, EN 61000-3-2
General data
Rated mains voltage and frequency range AC 100 V to 115 V/230 V at 50 Hz to 60 Hz
Rated power 35 W (meas.)
Operating temperature range +5 °C to +40 °C
Dimensions 222 mm × 97 mm × 291 mm
(8.74 in × 3.82 in × 11.5 in)
Weight approx. 3.25 kg (7.16 lb)

Available options

Socket adapter
Product
Description
R&S®NPA-Z1

Order number 3657.8911.02

Description

Mains adapter, EU version

R&S®NPA-Z2

Order number 3657.8911.03

Description

Mains adapter, UK version

R&S®NPA-Z3

Order number 3657.8911.04

Description

Mains adapter, US version

R&S®NPA-Z4

Order number 3657.8911.05

Description

Mains adapter, CHN/AUS version

Current probes
Product
Description
R&S®HZC50

Order number 3622.4690.02

Description

AC/DC current probe, 30 A, 4 mm connectors

R&S®HZC51

Order number 3622.4684.02

Description

AC/DC current probe, 1000 A, 4 mm connectors

Rackmount kit
Product
Description
R&S®HZC95

Order number 5800.2054.02

Description

19" rack adapter, 2HU, for R&S®NGE100B/NGC100/NPA and R&S®HMC series

Related videos

Conformance assessment of standby power consumption

Experience seamless in-device testing with the R&S NPA701 through an intuitive, step-by-step user-friendly wizard.

05-Apr-2024

Basic and advanced power measurement functions

Elevate your testing standards with the R&S NPA family, where precision meets simplicity.

05-Apr-2024

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.