Key Facts

  • High gain with low noise figure of  ≤4 dB
  • Bias unit eliminates the need for a power adapter at test sites
  • Hardened to withstand unintended pulses and ESD at the R&S®ESCU input
  • Compact and easy to mount on the R&S®UAS antenna stand

The evolution of preamplifiers

R&S®ESCU enhanced signal conditioning units cover the frequency range from 100 MHz to 18 GHz. The high performance preamplifier improves overall system sensitivity and is ideal for testing low-power signals.  A bias unit in the control room to power the R&S®ESCU significantly reduces potential power supply noise at test sites. Since preamplifiers are highly susceptible to ESD, the R&S®ESCU input is hardened to withstand high discharge levels for increased survivability, especially when connected to an antenna.

Features & benefits

Low noise figure suitable for EMI and RSE testing

R&S®ESCU preamplifiers lower the overall measurement noise floor by more than 10 dB for the limit lines specified in the EMI measurement standards .

Removal of potential noise emitter at test site

The R&S®ESCU comes with a bias unit that puts the power adapter outside the anechoic chamber. The bias unit carries DC power over an RF cable connected directly to the preamplifier.

Designed to withstand pulses, ESD
 

Low noise amplifiers or preamplifiers clearly reveal weak signals of interest. However, preamplifiers are extremely sensitive and susceptible to sudden incoming power surges. The R&S®ESCU helps counter the occasional pulse signals from equipment under test (EUT) during EMI testing. The R&S®ESCU input is hardened to withstand an ESD of over 8 KV.

Available models

Available models
Modelli
Frequency range
Minimum gain
Gain flatness
Noise figure
Maximum input level

R&S®ESCU08

Order Number 5602.9825.20

Frequency range
(30 MHz) 0.1 to 8 GHz
Minimum gain
≥ 33 dB
Gain flatness
≤ ±2 dB
Noise figure
≤ 3.5 dB
Maximum input level
+15 dBm

R&S®ESCU08

Order Number 5602.9825.30

Frequency range
(30 MHz) 0.1 to 8 GHz
Minimum gain
≥ 41 dB
Gain flatness
≤ ±2 dB
Noise figure
≤ 3.5 dB
Maximum input level
+15 dBm

R&S®ESCU18

Order Number 5602.9825.40

Frequency range
1 GHz to 18 GHz
Minimum gain
≥ 41 dB
Gain flatness
≤ ±2 dB
Noise figure
≤ 4 dB
Maximum input level
+15 dBm

R&S®ESCU08

Order Number 5602.9825.21

Frequency range
(30 MHz) 0.1 to 8 GHz
Minimum gain
≥ 31 dB
Gain flatness
≤ ±3 dB
Noise figure
≤ 3.5 dB
Maximum input level
+15 dBm

R&S®ESCU08

Order Number 5602.9825.31

Frequency range
(30 MHz) 0.1 to 8 GHz
Minimum gain
≥ 39 dB
Gain flatness
≤ ±3 dB
Noise figure
≤ 3.5 dB
Maximum input level
+15 dBm

R&S®ESCU18

Order Number 5602.9825.41

Frequency range
1 GHz to 18 GHz
Minimum gain
≥ 39 dB
Gain flatness
≤ ±3 dB
Noise figure
≤ 4 dB
Maximum input level
+15 dBm

Available options

Extras
Product
Descrizione
R&S®ESCU-Z10

Order Number 5602.9760.00

Descrizione

Mounting bracket for attaching the R&S®ESCU to the R&S®UAS antenna stand with the R&S®HF907 horn antenna. 

Rackmount kit
Product
Descrizione
R&S®ESCU-ZZA

Order Number 5602.9060.00

Descrizione

19" rackmount adapter 1 HU, for a single R&S®ESCU-Z01 

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Autorizzazione al marketing

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.