R&S®NRP-Z8x wideband power sensors

R&S®NRP-Z8x wideband power sensors
Ingrandisci immagine
R&S®NRP-Z8x wideband power sensors
Ingrandisci immagine
R&S®NRP-Z8x wideband power sensors
Ingrandisci immagine
R&S®NRP-Z8x wideband power sensors, Side view R&S®NRP-Z8x wideband power sensors, Application Image R&S®NRP-Z8x wideband power sensors, Application Image

Key Facts

  • Outstanding dynamic range and accuracy
  • High resolution mode
  • Highest measurement speed
  • Automatic pulse analysis
  • Statistical analysis
  • 3 year warranty extension

Ideal power sensor for radar applications

The R&S®NRP-Z81 wideband power sensors are ideal for radar applications. In development or during installation and maintenance, pulse characteristics as well as output power have to be measured. Similar measurements are required in the production of radar systems and radar components. Thanks to a maximum video bandwidth of 30 MHz and a rise/fall time of < 13 ns, the sensors can measure pulses with a pulse width as small as 50 ns. Key pulse parameters are determined automatically to simplify the measurement and prevent operating errors. By increasing the sampling rate, the high-resolution mode for repetitive signals permits the display of strongly magnified signal sections.

Features & benefits

High resolution mode

Achieve a time resolution of up to 100 ps

Some applications require the display of strongly magnified signal sections such as the rising edge of a pulse. To improve the graphical display in the trace mode, which has a resolution of 12.5 ns, a high density of samples is required. Equivalent time sampling with repetitive signals can achieve a time resolution of up to 100 ps.

Test setup with NRP-Z8x and NRX
Ingrandisci immagine

Test setup with NRP-Z8x and NRX

Automatic pulse analysis

Ideal with R&S NRX

Automatic pulse analysis supports users in measuring important pulse parameters, eliminating the need for complex measurements using markers. Changes in the pulse shape are immediately taken into account in the measurement results.

  • Time parameters: rise/fall time, start/stop time, pulse width, duty cycle, pulse period, pulse-off time
  • Level parameters: pulse top, pulse base, peak, average, minimum, overshoot (positive and negative)

Time parameters
Ingrandisci immagine

Time parameters

Ideal for radar applications

Analyze pulsed and modulated signals

The R&S®NRP-Z8x wideband power sensors are perfect for analyzing pulsed and/or modulated signals. Due to their high sampling rate of 80 Msample/s, the power envelope of radar pulses can be reconstructed with a time resolution of 12.5 ns. The sensors' automatic pulse analysis function makes it possible to measure 15 important pulse parameters automatically, which significantly simplifies and speeds up testing.

Radar application measurement with NRP-Z81
Ingrandisci immagine

Radar application measurement with NRP-Z81

Statistical analysis

Statistical analysis of the amplitude distribution

The R&S®NRP-Z8x wideband power sensors permit statistical analysis of the amplitude distribution of noise-like signals to determine key parameters such as peak envelope power, average power and peak-to-average power ratio. A measurement of the CCDF, CDF or PDF using one million samples can be performed by the R&S®NRP-Z8x wideband power sensors in less than 25 ms at full video bandwidth.

Trigger master mode

with base unit or R&S®NRP-Z5

Combined with the R&S®NRX base unit or the R&S®NRP-Z5 sensor hub, an R&S®NRP-Z8x wideband power sensor can be used as a trigger source. In the trigger master mode, a trigger signal is derived from the measured signal inside the power sensor and forwarded to the base unit or sensor hub for further use. All other connected sensors can be externally triggered using this trigger signal.

Operation with R&S®NRP-Z5
Ingrandisci immagine

Operation with R&S®NRP-Z5

Available models

Available models
Modelli
Frequency range
Level range
Connector type

R&S®NRP-Z81

Order Number 1137.9009.02

Frequency range
50 MHz - 18 GHz
Level range
-60 dBm - +20 dBm
Connector type
N (m)

R&S®NRP-Z85

Order Number 1411.7501.02

Frequency range
50 MHz - 40 GHz
Level range
-60 dBm - +20 dBm
Connector type
2.92 mm (m)

R&S®NRP-Z86

Order Number 1417.0109.40

Frequency range
50 MHz - 40 GHz
Level range
-60 dBm - +20 dBm
Connector type
2.4 mm (m)

R&S®NRP-Z86

Order Number 1417.0109.44

Frequency range
50 MHz - 44 GHz
Level range
-60 dBm - +20 dBm
Connector type
2.4 mm (m)

Available options

Cables and adapters
Product
Descrizione
R&S®NRP-Z2

Order Number 1146.6750.03

Descrizione

Sensor extension cable

Sensor extension cable to 3 meters.

R&S®NRP-Z2

Order Number 1146.6750.05

Descrizione

Sensor extension cable

Sensor extension cable to 5 meters.

R&S®NRP-Z2

Order Number 1146.6750.10

Descrizione

Sensor extension cable

Sensor extension cable to 10 meters.

R&S®NRP-Z2

Order Number 1146.6750.15

Descrizione

Sensor extension cable

Sensor extension cable to 5m, with bulkhead jack.

R&S®NRP-Z4

Order Number 1146.8001.02

Descrizione

USB adapter cable (passive), length: 2 m

R&S®NRP-Z4

Order Number 1146.8001.04

Descrizione

USB adapter cable (passive), length: 0.5 m

R&S®NRP-Z4

Order Number 1146.8001.06

Descrizione

USB adapter cable (passive), length: 0.15 m

R&S®NRP-Z4

Order Number 1146.8001.11

Descrizione

USB adapter cable (passive), length: 1 m, for panel mounting

Interface accessories
Product
Descrizione
R&S®NRP-Z5

Order Number 1146.7740.02

Descrizione

USB sensor hub

R&S®NRP-Z5 can host up to 4 R&S®NRPxxS(N), R&S®NRPxxT(N), R&S®NRPxxA(N) or R&S®NRP-Z sensors. A professional trigger solution allows simultaneous internal and external triggering of all connected sensors.

Documentation
Product
Descrizione
R&S®DCV-1

Order Number 0240.2187.06

Descrizione

Documentation of calibration values

R&S®DCV-ZP

Order Number 1173.6506.02

Descrizione

Printout of DCV

Richiedi informazioni

Hai qualche domanda o ti servono altre informazioni? Compila il modulo e ti ricontatteremo al più presto.

Desidero ricevere informazioni da Rohde & Schwarz tramite

Autorizzazione al marketing

Cosa significa nello specifico?

Accetto che ROHDE & SCHWARZ GmbH & Co. KG e l’entità ROHDE & SCHWARZ o l’azienda controllata riportata nelle note legali di questo sito web, potrà contattarmi tramite il canale prescelto (e-mail o posta) per scopi di marketing e pubblicità (ad es., informazioni su offerte speciali e sconti) in relazione a, in via non limitativa, prodotti e soluzioni del settore di collaudo e misurazione, comunicazioni sicure, monitoraggio e collaudo di rete, trasmissione, media e sicurezza informatica.

I tuoi diritti

La presente dichiarazione di consenso può essere revocata in qualsiasi momento inviando una e-mail con oggetto “Annulla iscrizione" all’indirizzo news@rohde-schwarz.com. In più, in ciascuna e-mail pubblicitaria inviata sarà allegato un link per annullare l’iscrizione. Nella ”Dichiarazione di riservatezza” vengono definiti ulteriori dettagli sull’utilizzo dei dati personali e sulla procedura di ritiro.

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.