R&S®NRPxxP Pulse power sensor

R&S®NRPxxP Pulse power sensor
Ingrandisci immagine
R&S®NRPxxP Pulse power sensor
Ingrandisci immagine
R&S®NRPxxP Pulse power sensor
Ingrandisci immagine
R&S®NRPxxP Pulse power sensor
Ingrandisci immagine
R&S®NRPxxP Pulse power sensor
Ingrandisci immagine
R&S®NRPxxP Pulse power sensor, Application Image R&S®NRPxxP Pulse power sensor, Application Image R&S®NRPxxP Pulse power sensor, Front view R&S®NRPxxP Pulse power sensor, Front view R&S®NRPxxP Pulse power sensor, Front view

Key Facts

  • Outstanding dynamic range and accuracy
  • High resolution mode
  • Highest measurement speed
  • Automatic pulse analysis
  • Statistical analysis

Ideal power sensor for radar applications

The R&S®NRPxxP pulse power sensors are ideal for radar applications. Pulse characteristics and output power have to be measured in the development process or during installation and maintenance. Similar measurements are required in the production of radar systems and radar components. A maximum video bandwidth of 30 MHz and a rise/fall time of < 13 ns mean the sensors can measure pulse widths that are as short as 50 ns. Key pulse parameters are determined automatically for simpler measurements and to help prevent operating errors. By increasing the sampling rate, the high-resolution mode for repetitive signals can display strongly magnified signal sections.

Features & benefits

High resolution mode

Time resolution of up to 100 ps

Some applications require the display of strongly magnified signal sections such as the rising edge of a pulse. The trace mode has a resolution of 12.5 ns and requires high sample density to improve the graphical display. Equivalent time sampling with repetitive signals enables a time resolution of up to 100 ps.

Test setup with R&S®NRP18P and R&S®NRX
Ingrandisci immagine

Test setup with R&S®NRP18P and R&S®NRX

Automatic pulse analysis

Ideal with R&S®NRX

Automatic pulse analysis helps measure important pulse parameters, eliminating the need for complex measurements with markers. Changes in the pulse shape are immediately taken into account in the measurement results.

  • Time parameters: rise/fall time, start/stop time, pulse width, duty cycle, pulse period, pulse-off time
  • Level parameters: pulse top, pulse base, peak, average, minimum, overshoot (positive and negative)

Time parameters
Ingrandisci immagine

Time parameters

Ideal for radar applications

Analyze pulsed and modulated signals

The R&S®NRPxxP pulse power sensors are perfect for analyzing pulsed and/or modulated signals. The high sampling rate of 80 Msample/s allows the power envelope of radar pulses to be reconstructed with a time resolution of 12.5 ns. The automatic pulse analysis function can measure 15 important pulse parameters automatically to simplify and speed up testing.

Radar application measurement with NRPxxP
Ingrandisci immagine

Radar application measurement with NRPxxP

Statistical analysis

Statistical analysis of the amplitude distribution

The R&S®NRPxxP pulse power sensors permit statistical analysis of the amplitude distribution of noise-like signals to determine key parameters such as peak envelope power, average power and peak-to-average power ratio. A measurement of the CCDF, CDF or PDF using one million samples can be performed by the R&S®NRPxxP pulse power sensors in less than 25 ms at full video bandwidth.

Trigger sender mode

with base unit or R&S®NRP-Z5;

Combined with the R&S®NRX base unit or the R&S®NRP-Z5 sensor hub, an R&S®NRPxxP pulse power sensor can be used as a trigger source. In trigger sender mode, a trigger signal is derived from the measured signal inside the power sensor and forwarded to the base unit or sensor hub for further use. All other connected sensors can be externally triggered using this trigger signal.

Operation with R&S®NRP-Z5
Ingrandisci immagine

Operation with R&S®NRP-Z5

Available models

Available models
Modelli
Frequency range
Level range
Connector type

R&S®NRP18P

Order Number 1444.1190.02

Frequency range
50 MHz - 18 GHz
Level range
-60 dBm - 20 dBm
Connector type
N (m)

R&S®NRP40P

Order Number 1444.1290.02

Frequency range
50 MHz - 40 GHz
Level range
-60 dBm - +20 dBm
Connector type
2.92 mm (m)

R&S®NRP50P

Order Number 1444.1390.02

Frequency range
50 MHz - 50 GHz
Level range
-60 dBm - 20 dBm
Connector type
2.4 mm (m)

Available options

Interface cables
Product
Descrizione
R&S®NRP-ZKU

Order Number 1419.0658.02

Descrizione

USB-A interface cable, length: 0.75 m

R&S®NRP-ZKU

Order Number 1419.0658.03

Descrizione

USB-A interface cable, length: 1.5 m

R&S®NRP-ZKU

Order Number 1419.0658.04

Descrizione

USB-A interface cable, length: 3 m

R&S®NRP-ZKU

Order Number 1419.0658.05

Descrizione

USB-A interface cable, length: 5 m

R&S®NRP-ZKC

Order Number 1425.2442.02

Descrizione

USB-C interface cable, length: 0.75 m

R&S®NRP-ZKC

Order Number 1425.2442.03

Descrizione

USB-C interface cable, length: 1.5 m

R&S®NRP-ZKC

Order Number 1425.2442.04

Descrizione

USB-C interface cable, length: 3.0 m

R&S®NRP-ZK6

Order Number 1419.0664.03

Descrizione

6-pole interface cable, length: 3 m

R&S®NRP-ZK8

Order Number 1424.9408.02

Descrizione

8-pole interface cable, length: 1.50 m

For connection to R&S®NRX

R&S®NRP-ZK8

Order Number 1424.9408.03

Descrizione

8-pole interface cable, length: 3.00 m

For connection to R&S®NRX

R&S®NRP-ZK8

Order Number 1424.9408.04

Descrizione

8-pole interface cable, length: 5.00 m

For connection to R&S®NRX

General
Product
Descrizione
R&S®NRP-Z5

Order Number 1146.7740.02

Descrizione

USB sensor hub

R&S®NRP-Z5 can host up to 4 R&S®NRPxxS(N), R&S®NRPxxT(N), R&S®NRPxxA(N) or R&S®NRP-Z sensors. A professional trigger solution allows simultaneous internal and external triggering of all connected sensors.

R&S®DCV-ZP

Order Number 1173.6506.02

Descrizione

Printout of DCV

Documentation
Product
Descrizione
R&S®DCV-1

Order Number 0240.2187.06

Descrizione

Documentation of calibration values

Interface cables
Product
Descrizione
R&S®NRP-ZK6

Order Number 1419.0664.02

Descrizione

6-pole interface cable, length: 1.5 m

R&S®NRP-ZK6

Order Number 1419.0664.04

Descrizione

6-pole interface cable, length: 5 m

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Autorizzazione al marketing

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.