R&S®RTM3000 oscilloscopes

R&S®RTM3000 oscilloscope
Ingrandisci immagine
R&S®RTM3000 oscilloscope, front view
Ingrandisci immagine
R&S®RTM3000 oscilloscope, side view
Ingrandisci immagine
R&S®RTM3000 oscilloscope
Ingrandisci immagine
R&S®RTM3000 oscilloscope
Ingrandisci immagine
The oscilloscope R&S®RTM3000
Ingrandisci immagine
R&S®RTM3000 oscilloscope R&S®RTM3000 oscilloscope, front view R&S®RTM3000 oscilloscope, side view R&S®RTM3000 oscilloscope R&S®RTM3000 oscilloscope The oscilloscope R&S®RTM3000

Key facts

  • Bandwidth: 100 MHz to 1GHz
  • Sample rate: up to 5 Gsample/s
  • Memory depth: up to 80 Msample
  • ADC resolution: 10-bit
  • Display: 10.1’’ capacitive touchscreen

A partire da EUR 3.230

See more of your signal with the power of 10

Designed as daily problem-solving tool, the R&S®RTM3000 combines the power of ten (10-bit ADC, 10 times the memory and 10.1" touchscreen) with a Rohde & Schwarz probe interface for all Rohde & Schwarz probes.

I    Four times more vertical resolution than standard 8-bit ADCs
I    Maintains fast sampling rates at all times
I    10.1" touchscreen with gesture support

Features & benefits

Signal analysis: quick results

See small signal details in the presence of large signals

The R&S®RTM3000 features a customized Rohde & Schwarz designed 10-bit A/D converter that delivers a four-fold improvement over conventional 8-bit A/D converters. The increased resolution results in sharper waveforms with more signal details that would otherwise be missed. One example is the characterization of switched-mode power supplies. The voltages across the switching device must be determined during the on/off times within the same acquisition.

RTM3000 oscilloscope
Open Lightbox

10-bit A/D converter

10-bit A/D converter uncovers even small signal details and ensures a vertical resolution four times higher than traditional oscilloscopes.

Segmented memory

40 Msample standard and 80 Msample interleaved

The R&S®RTM3000 offers a class-leading memory depth: 40 Msample per channel are available, even 80 Msample in interleaved mode. This is eight times more than similar oscilloscopes in the same instrument class. The user captures longer acquisition sequences even at high sampling rates for more analysis results, e.g. when analyzing transients of switched-mode power supplies.

RTM3000 oscilloscope
Open Lightbox

40 Msample standard memory

Capture and analyze pulsed and burst signals over a long period with up to 80 Msample standard acquisition memory

Capture more time at full bandwidth

Segmented memory: 400 Msample with history function

The R&S®RTM-K15 option with deep, segmented memory analyzes signal sequences over a long observation period. Protocol-based signals with communications gaps such as I²C or SPI can be captured over several seconds or minutes. Thanks to the variable segment size the 400 Msample memory is optimally utilized. In history mode, previous acquisitions to the maximum segmented memory depth of 400 Msample are available for further analysis.

RTM3000 oscilloscope
Open Lightbox

400 Msample segmented memory

Capture the longest time periods with class-leading 400 Msample memory

Logic analysis with the MSO option

16 additional digital channels

The R&S®RTM-B1 option turns every R&S®RTM3000 into an intuitive-to-use MSO with 16 additional digital channels. The oscilloscope captures and analyzes signals from analog and digital components of an embedded design – synchronously and timecorrelated to each other. For example, the delay between input and output of an A/D converter can conveniently be determined using the cursor measurements.

RTM3000 oscilloscope
Open Lightbox

4-bit DAC signal change

The R&S®RTM3000 captures and analyzes analog and digital signals synchronously and time-correlated with each other.

Waveform and pattern generator

Generate analog and digital stimuli

The R&S®RTM-B6 waveform and pattern generator up to 50 Mbit/s is useful for educational purposes and for implementing prototype hardware. Apart from the common sine, square/pulse, ramp and noise waveforms, it outputs arbitrary waveforms and 4-bit signal patterns. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. Predefined patterns for e.g. I2C, SPI, UART and CAN/LIN can be used.

RTM3000 oscilloscope
Open Lightbox

Waveform and pattern generator

In addition to common sine, square/pulse, ramp and noise waveforms, it outputs user-defined waveforms and 4-bit signal patterns.

Digital voltmeter

Measure and display electrical potential

The R&S®RTM3000 features a 3-digit voltmeter (DVM) and 6-digit frequency counter on each channel for simultaneous measurements. Measurement functions include DC, AC+DC (RMS) and AC (RMS) – included as standard.

RTM3000 oscilloscope
Open Lightbox

Digital voltmeter

The 3-digit voltmeter measures and displays the electrical potential difference between two points in an electric circuit.

Frequency analysis mode

Difficult-to-find faults often result from the interaction between time and frequency signals. The FFT function of the R&S®RTM3000 is activated at the push of a button and by simpling entering the center frequency and span. Thanks to the R&S®RTM3000 oscilloscopes’ high-performance FFT functionality, signals can be analyzed with up to 128k points. Other practical tools include cursor measurements and autoset in frequency domain.

RTM3000 oscilloscope
Open Lightbox

FFT of a square wave

The high-performance FFT functionality analyzes signals up to 128k points.

Mask test mode

Mask tests quickly reveal whether a specific signal lies within defined tolerance limits. Masks assess the quality and stability of a DUT based on statistical pass/fail evaluation. Signal anomalies and unexpected results are quickly identified. When the mask is violated, the measurement stops. Each violation can generate a pulse output at the AUX-OUT connector on the R&S®RTM3000. This pulse output can be used to trigger actions in the measurement setup.

RTM3000 oscilloscope
Open Lightbox

Mask test with result statistics

The pass/fail evaluation assesses the quality and stability of the DUT

The best choice for power

See power signal details with up to 10-bit resolution

Even the smallest signal details of a high dynamic signal matter for power measurements. Verification of RDS(on) of a MOSFET is one example. The high ADC resolution of the R&S®RTM3000 oscilloscopes increases the vertical resolution up to 10 bit. Previously unseen signal details become visible and measurable. In the example of RDS(on), it makes it possible to measure the slope of the drain-to-source-voltage while the switch is closed.

RTM3000 oscilloscope
Open Lightbox

Power analysis

Analyze the input, output and transfer function of switched-mode power supplies

Available models
Product Name
Bandwidth
Channels
Sample Rate
Max. Memory Depth
Optional MSO
Starting at
R&S®RTM3002

Order number 1335.8794.02

Bandwidth
100 MHz
Channels
2
Sample Rate
5 Gsample/s
Max. Memory Depth
80 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTM3004

Order number 1335.8794.04

Bandwidth
100 MHz
Channels
4
Sample Rate
5 Gsample/s
Max. Memory Depth
80 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTM3002 + RTM-B222

Order number 1335.8794P22

Bandwidth
200 MHz
Channels
2
Sample Rate
5 Gsample/s
Max. Memory Depth
80 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTM3004 + RTM-B242

Order number 1335.8794P24

Bandwidth
200 MHz
Channels
4
Sample Rate
5 Gsample/s
Max. Memory Depth
80 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTM3002 + RTM-B223

Order number 1335.8794P32

Bandwidth
350 MHz
Channels
2
Sample Rate
5 Gsample/s
Max. Memory Depth
80 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTM3004 + RTM-B243

Order number 1335.8794P34

Bandwidth
350 MHz
Channels
4
Sample Rate
5 Gsample/s
Max. Memory Depth
80 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTM3002 + RTM-B225

Order number 1335.8794P52

Bandwidth
500 MHz
Channels
2
Sample Rate
5 Gsample/s
Max. Memory Depth
80 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTM3004 + RTM-B245

Order number 1335.8794P54

Bandwidth
500 MHz
Channels
4
Sample Rate
5 Gsample/s
Max. Memory Depth
80 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTM3002 + RTM-B2210

Order number 1335.8794P62

Bandwidth
1 GHz
Channels
2
Sample Rate
5 Gsample/s
Max. Memory Depth
80 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTM3004 + RTM-B2410

Order number 1335.8794P64

Bandwidth
1 GHz
Channels
4
Sample Rate
5 Gsample/s
Max. Memory Depth
80 Msample
Optional MSO
16 digital channels
Starting at
Specifications
Vertical system
Number of channels R&S®RTM3002; R&S®RTM3004 2; 4
Bandwidth (–3 dB) at 50 Ω R&S®RTM3002/3004 (with R&S®RTM-B2x2/-B2x3/-B2x5/-B2x10 options) 100 MHz, 200 MHz, 350 MHz, 500 MHz, 1 GHz
Rise time (calculated) R&S®RTM3002/3004 (with R&S®RTM-B2x2/-B2x3/-B2x5/-B2x10 options) 3.5 ns, 1.75 ns, 1 ns, 700 ps, 350 ps
Input impedance   50 Ω ± 1,5% (meas.), 1 MΩ ± 1 % (meas.) || 14 pF ± 1 pF (meas.)
Input sensitivity max. bandwidth in all ranges  
  at 1 MΩ 500 μV/div to 10 V/div
  at 50 Ω 500 μV/div to 1 V/div
DC gain accuracy offset and position = 0, maximum operating temperature change of ±5°C after self-alignment
  input sensitivity > 5 mV/div ±1.5 % of full scale
  input sensitivity > 5 mV/div ±2 % of full scale
ADC resolution   10-bit, up to 16-bit with high resolution decimation
Acquisition system
Maximum realtime sampling rate   2.5 Gsample/s; 5 Gsample/s, interleaved
Acquisition memory standard; 40 Msample (80 Msample interleaved)
  with R&S®RTM-K15 option 400 Msample segmented memory
Horizontal system
Timebase range   selectable between 0.5 ns/div and 500 s/div
Trigger system
Trigger types standard edge, width, video (PAL, NTSC, SECAM, PAL-M, SDTV 576i, HDTV 720p, HDTV 1080i, HDTV 1080p), pattern, line, serial bus, timeout
  option I2C, SPI, UART/RS-232/RS-422/RS-485, CAN/LIN,ARINC 429, MIL-STD-1553
MSO option
Digital channels   16 (2 logic probe)
Sampling rate   2.5 Gsample/s
Acquisition memory standard; 40 Msample (80 Msample interleaved)
  with R&S®RTM-K15 option 400 Msample segmented memory
Waveform generator option
Resolution, sample rate   14-bit, 250 Msample/s
Amplitude high Z; 50 Ω 20 mV to 5 V (Vpp); 10 mV to 2.5 V (Vpp)
DC offset high Z; 50 Ω ±5 V; ±2.5 V
Signal forms frequency ranges sine 0.1 Hz to 25 MHz
  pulse/rectangle 0.1 Hz to 10 MHz
  ramp/triangle 0.1 Hz to 1 MHz
  noise max. 25 MHz
Arbitrary sampling rate; memory depth max. 10 Msample/s; 32k points
General data
Screen   10.1" WXGA TFT color display (1280 × 800 pixel)
Interfaces   USB host with MTP, USB device, LAN, powerful web server for remote display and operation
Audible noise maximum sound pressure level at a distance of 1.0 m 28.3 dB(A)
Dimensions W × H × D 390 mm × 220 mm × 152 mm
(15.4 in × 8.66 in × 5.98 in)
Weight   3.3 kg (7.27 lb)

Available options

General
Product
Description
RTM-B1 Mixed signal option, 400 MHz

Order number 1335.8988.02

Description
Mixed signal option, 400 MHz
Turns the R&S®RTM3000 oscilloscope into fast, precise and easy-to-use mixed signal oscilloscopes (MSO)
Waveform generator
R&S®RTM-B6

Order number 1335.8994.02

Description
Arbitrary waveform generator
Adds a 25 MHz signal generator and a 4-bit pattern generator to your R&S®RTM3000 oscilloscope.
Bandwidth upgrade
Product
Description
Bandwidth upgrade
R&S®RTM-B222

Order number 1335.9003.02

Description
Bandwidth upgrade of the R&S®RTM3002 to 200 MHz bandwidth
Bandwidth upgrade
R&S®RTM-B223

Order number 1335.9010.02

Description
Bandwidth upgrade of the R&S®RTM3002 to 350 MHz bandwidth
Bandwidth upgrade
R&S®RTM-B225

Order number 1335.9026.02

Description
Bandwidth upgrade of the R&S®RTM3002 to 500 MHz bandwidth
Bandwidth upgrade
R&S®RTM-B2210

Order number 1335.9032.02

Description
Bandwidth upgrade of the R&S®RTM3002 to 1GHz bandwidth
Bandwidth upgrade
R&S®RTM-B242

Order number 1335.9049.02

Description
Bandwidth upgrade of the R&S®RTM3004 to 200 MHz bandwidth
Bandwidth upgrade
R&S®RTM-B243

Order number 1335.9055.02

Description
Bandwidth upgrade of the R&S®RTM3004 to 350 MHz bandwidth
Bandwidth upgrade
R&S®RTM-B245

Order number 1335.9061.02

Description
Bandwidth upgrade of the R&S®RTM3004 to 500 MHz bandwidth
Bandwidth upgrade
R&S®RTM-B2410

Order number 1335.9078.02

Description
Bandwidth upgrade of the R&S®RTM3004 to 1 GHz bandwidth
Serial triggering and decoding
Product
Description
I²C/SPI serial triggering and decoding

Order number 1335.8807.02

Description
I²C/SPI serial triggering and decoding
Triggering and decoding of I²C and 2-wire, 3-wire or 4-wire SPI buses
serial triggering and decoding

Order number 1335.8813.02

Description
UART/RS-232/RS-422/RS-485 serial triggering and decoding
Triggering and decoding of UART based protocols and RS-232, RS-422 as well as RS-485 buses
serial triggering and decoding

Order number 1335.8820.02

Description
CAN/LIN serial triggering and decoding
Triggering and decoding of CAN and LIN interfaces
serial triggering and decoding

Order number 1335.8842.02

Description
I²S/LJ/RJ/TDM triggering and decoding
Triggering and decoding of I²S buses
serial triggering and decoding

Order number 1335.8859.02

Description
MIL-1553 serial triggering and decoding
Triggering and decoding of MIL-STD-1553 buses
serial triggering and decoding

Order number 1335.8865.02

Description
ARINC 429 serial triggering and decoding
Triggering and decoding of ARINC 429 buses
General analysis
Product
Description
History and segmented memory

Order number 1335.8907.02

Description
History and segmented memory
History and 400 Msample segmented memory.
Power analysis

Order number 1335.8920.02

Description
Power analysis
When analyzing power electronics, the input and output and the internal transfer function of the component have to be characterized. The power analysis option provides the necessary measurement functions, including inrush current, output spectrum and safe operating area (SOA).
Oscilloscope-Software-RTx-K36-Frequency-Response-Analysis-Bode-plot.png

Order number 1335.9178.02

Description
Frequency Response Analysis (Bode plot)
The R&S®RTM-K36 frequency response analysis (Bode plot) option lets you perform low-frequency response analysis on your oscilloscope easily and quickly. It characterizes the frequency response of a variety of electronic devices, including passive filters and amplifier circuits. For switch mode power supplies, it measures the control loop response and power supply rejection ratio.
Spectrum analysis and spectrogram

Order number 1335.9184.02

Description
Spectrum analysis and spectrogram
The spectrum analysis option enhances the powerful FFT capability of R&S®RTM3000 oscilloscopes with spectrogram display
General accessories
Product
Description
Front Cover
R&S®RTB-Z1

Order number 1333.1728.02

Description
Front cover
Protects the front of the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000
Transit-Case
R&S®RTB-Z4

Order number 1335.9290.02

Description
Transit case with wheels for R&S®RTB
Soft Bag
R&S®RTB-Z3

Order number 1333.1734.02

Description
Soft bag
Stores the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 oscilloscope and accessories
RT-ZA19 Accessory case
R&S®RT-ZA19

Order number 1335.7875.02

Description
Accessory case for probes and small parts for all Rohde and Schwarz oscilloscopes
ZZA-RTB2K
R&S®ZZA-RTB2K

Order number 1333.1711.02

Description
19" rackmount adapter for R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 with 5HU
R&S®Z2T Probe adapter
R&S®RT-Z2T

Order number 1338.0007.02

Description
Probe adapter
Enables Tek’s TekProbe-BNC level 2 probes to connect to Rohde & Schwarz probe interface
Passive probes
Product
Description
Passive-Probes_RT-ZP05

Order number 1333.2401.02

Description
Passive probe, 500 MHz, 10:1
 RTM-ZP10 Passive probe

Order number 1409.7708.02

Description
Passive probe, 500 MHz, 10:1
RT-ZP1x Passive probe

Order number 1333.1370.02

Description
Passive probe, 38 MHz, 1:1
Active single-ended probes
Product
Description
Active single-ended probe, 1 GHz, BNC interface

Order number 1333.0815.02

Description
Active single-ended probe, 1 GHz, BNC interface
RT-ZS10E Active single-ended probe

Order number 1418.7007.02

Description
Active single-ended probe, 1 GHz, Rohde & Schwarz probe interface
RT-ZS10 Active single-ended probe

Order number 1410.4080.02

Description
Active single-ended probe, 1 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
RT-ZS20 Active single-ended probe

Order number 1410.3502.02

Description
Active single-ended probe, 1.5 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Active differential probes
Product
Description
RT-ZD10 Active differential probe

Order number 1410.4715.02

Description
Active differential probe, 1 GHz, Rohde & Schwarz probe interface
Active differential probe, 1 GHz, Rohde & Schwarz probe interface
R&S®RT-ZD20 Active differential probe

Order number 1410.4409.02

Description
Active differential probe, 1.5 GHz, Rohde & Schwarz probe interface
Power rail probes
Product
Description
RT-ZPR20 Power rail probes

Order number 1800.5006.02

Description
Power rail probe, 2 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
High voltage probes
Product
Description
RT-ZH03 - 250 MHz Passive high voltage probe

Order number 1333.0873.02

Description
250 MHz passive high voltage probe
RT-ZH10 High voltage probe

Order number 1409.7720.02

Description
400 MHz passive high voltage probe
RTZH10_front.jpg

Order number 1409.7737.02

Description
400 MHz passive high voltage probe
25 MHz High voltage differential probe

Order number 1337.9700.02

Description
25 MHz high voltage differential probe
25 MHz High voltage differential probe

Order number 1337.9800.02

Description
25 MHz high voltage differential probe
RT-ZD01 High voltage probe

Order number 1422.0703.02

Description
100 MHz high voltage differential probe
RT-ZD02 Active differential probe, 200 MHz, BNC interface

Order number 1333.0821.02

Description
Active differential probe, 200 MHz, BNC interface
RTZD08 Active differential probe, 800 GHz, BNC interface

Order number 1333.0838.02

Description
Active differential probe, 800 GHz, BNC interface
RT-ZHD07 High voltage probe

Order number 1800.2307.02

Description
200 MHz high voltage differential probe
RT-ZHD15 High voltage probe

Order number 1800.2107.02

Description
100 MHz high voltage differential probe
RT-ZHD16 200 MHz High voltage differential probe

Order number 1800.2207.02

Description
200 MHz high voltage differential probe
RT-ZHD60 High voltage probe

Order number 1800.2007.02

Description
100 MHz high voltage differential probe
Current probes
Product
Description
RT-ZC02 AC/DC 20 KHZ Current probe

Order number 1333.0850.02

Description
AC/DC 20 kHz current probe
RT-ZC03 100 KHZ Current probe

Order number 1333.0844.02

Description
100 kHz current probe
RT-ZC05B 2 MHz Current probe

Order number 1409.8204.02

Description
2 MHz current probe
RT-ZC10 10 MHz Current probe

Order number 1409.7750K02

Description
10 MHz current probe
RT-ZC10B 10 MHz Current probe

Order number 1409.8210.02

Description
10 MHz current probe
RT-ZC15B 50 MHz Current probe

Order number 1409.8227.02

Description
50 MHz current probe
RT-ZC20 20 MHz Current probe

Order number 1409.7766K02

Description
100 MHz current probe
RT-ZC20B 100 MHz Current probe

Order number 1409.8233.02

Description
100 MHz current probe
RT-ZC30 120 MHz Current probe

Order number 1409.7772K02

Description
120 MHz current probe
R&S®RT-ZC31

Order number 1801.4932.02

Description
120 MHz current probe
EMC near-field probes
Product
Description
HZ15_front.jpg

Order number 1147.2736.02

Description
E and H near-field probe set
Logic probes
Product
Description
RT-ZL04 400 MHz logic probe
R&S®RT-ZL04

Order number 1333.0721.02

Description
400 MHz logic probe
Probe accessories
Product
Description
RT-ZA13 Power supply for probes
R&S®RT-ZA13

Order number 1409.7789.02

Description
Power supply for probes
Power supply for R&S®RT-ZC10/20/30 probes, +/-12V DC, +/-2.5A
RT-ZA15 External Attenuator
R&S®RT-ZA15

Order number 1410.4744.02

Description
External attenuator
10:1, 2.0 GHz, 1.3 pF, 60 V DC, 42 V AC (peak) for R&S®RT-ZD20/30 probes. Included in R&S®RT-ZD10.
Application bundles
Product
Description
Application bundle
R&S®RTM-PK1

Order number 1335.8942.02

Description
Application bundle (R&S®RTM-K1, -K2, -K3, -K5, -K6, -K7, -K15, -K31, -K36, -K37 and -B6)
Application bundle contains triggering and decoding I²C/SPI (R&S®RTM-K1), UART/RS-232/RS-422/RS-485 (R&S®RTM-K2) and CAN/LIN (R&S®RTM-K3), I²S (R&S®RTM-K5), MIL-1553 (R&S®RTM-K6), ARINC429 (R&S®RTM-K7) history and segmented memory (R&S®RTM-K15), spectrum analysis and spectrogram (R&S®RTM-K37), power analysis (R&S®RTM-K31), frequency response analysis (R&S®RTM-K36), arbitrary generator (R&S®RTM-B6) for R&S®RTM3000 models
Application bundle
R&S®RTM-PK1US*

Order number 1335.9190.02

Description
Application bundle (R&S®RTM-K1, -K2, -K3, -K5, -K6, -K7, -K15, -K31, -K36, -K37 and -B6)
Application bundle contains triggering and decoding I²C/SPI (R&S®RTM-K1), UART/RS-232/RS-422/RS-485 (R&S®RTM-K2) and CAN/LIN (R&S®RTM-K3), I²S (R&S®RTM-K5), MIL-1553 (R&S®RTM-K6), ARINC429 (R&S®RTM-K7) history and segmented memory (R&S®RTM-K15), power analysis (R&S®RTM-K31), frequency response analysis (R&S®RTM-K36), spectrum analysis and spectrogram (R&S®RTM-K37), arbitrary generator (R&S®RTM-B6) for R&S®RTM3000 models
* ONLY distributed in North America
Application packages
Product
Description
Application package
R&S®RTM3K-LSSB

Order number 1335.9149P02

Description
Low-speed serial bus package (R&S®RTM3004, -K1, -K2, -K15, -B1)
Low-speed serial bus package, contains base unit of R&S®RTM3004, trigger and decoding I2C/SPI (R&S®RTM-K1), UART/RS-232/RS-422/RS-485 (R&S®RTM-K2), History and Segmented Memory (R&S®RTM-K15) and Mixed Signal Option (R&S®RTM-B1)
Application package
R&S®RTM3K-HVP2

Order number 1335.9132P02

Description
High voltage power package (R&S®RTM3002, R&S®RT-ZHD60)
High voltage power package, contains base unit of R&S®RTM3002 and high voltage differential probe R&S®RT-ZHD60
Application package
R&S®RTM3K-HVP4

Order number 1335.9132P04

Description
High voltage power package (R&S®RTM3004, R&S®RT-ZHD60)
High voltage power package, contains base unit of R&S®RTM3004 and high voltage differential probe R&S®RT-ZHD60
Application package
R&S®RTM3K-PS

Order number 1335.9126P02

Description
Power supply package (R&S®RTM3004, -K31, R&S®RT-ZHD07, R&S®RT-ZC15B)
Power supply package, contains base unit of R&S®RTM3004, Power Analysis Option (R&S®RTM-K31), high voltage differential probe R&S®RT-ZHD07, and current probe R&S®RT-ZC15B

R&S®RTM3000 - Media center

R&S®RTM3000 - Media center

Vedi di più

Video applicativi degli oscilloscopi - Media Center

Vedi di più

Altri temi di interesse

10 anni di innovazioni per gli oscilloscopi Rohde & Schwarz

Maggiori informazioni

Promozione sugli oscilloscopi

Scegliete la promozione Rohde & Schwarz più adatta alle vostre esigenze e risparmiate

Maggiori informazioni

Webinar su oscilloscopi per applicazioni di elettronica di potenza e progettazione digitale

Maggiori informazioni

Software per laboratori didattici multiutente

Il software R&S®CDS campus dashboard semplifica l'insegnamento a gruppi di studenti in laboratori con banchi di lavoro multipli.

Informazioni sul prodotto

Solutions for

Analog/digital design and test

Check out Rohde & Schwarz solutions for signal and power integrity, measurement of small signals and EMI debugging.

More information

Power electronics testing

Let our test und measurement solutions assist you to create low power consuming and reliable product.

More information

Famiglie di oscilloscopi

Software per oscilloscopi

Espandi le capacità del tuo oscilloscopio con il software applicativo Rohde & Schwarz.

Maggiori informazioni

Sonde per oscilloscopi

Personalizza il tuo oscilloscopio con le sonde e gli accessori più adatti per la tua applicazione.

Maggiori informazioni

Richiedi informazioni

Hai qualche domanda o ti servono altre informazioni? Compila il modulo e ti ricontatteremo al più presto.

Desidero ricevere informazioni da Rohde & Schwarz tramite

Autorizzazione al marketing

Cosa significa nello specifico?

Accetto che ROHDE & SCHWARZ GmbH & Co. KG e l’entità ROHDE & SCHWARZ o l’azienda controllata riportata nelle note legali di questo sito web, potrà contattarmi tramite il canale prescelto (e-mail o posta) per scopi di marketing e pubblicità (ad es., informazioni su offerte speciali e sconti) in relazione a, in via non limitativa, prodotti e soluzioni del settore di collaudo e misurazione, comunicazioni sicure, monitoraggio e collaudo di rete, trasmissione, media e sicurezza informatica.

I tuoi diritti

La presente dichiarazione di consenso può essere revocata in qualsiasi momento inviando una e-mail con oggetto “Annulla iscrizione" all’indirizzo news@rohde-schwarz.com. In più, in ciascuna e-mail pubblicitaria inviata sarà allegato un link per annullare l’iscrizione. Nella ”Dichiarazione di riservatezza” vengono definiti ulteriori dettagli sull’utilizzo dei dati personali e sulla procedura di ritiro.

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.