Trigger and decode software application bundles

For MXO oscilloscopes

Trigger and decode software application bundles
Show me more details

주요 사항

  • All trigger and decode software options in one package
  • Permanent software licenses without maintenance fees and regular SW enhancements on standard and optional features through free firmware upgrades
  • High value offering: get the software options at a significantly lower cost than buying them individually
  • Combine with 4 Ch or 8 Ch MXO oscilloscope with bandwidths ranging from 100 MHz to 2 GHz
  • MXO oscilloscopes have an update rate > 4.5 million waveforms per second and industry leading spectrum acquisition rate of 50,000 FFT/s, with up to 4 spectra

Trigger and decode software application bundle

Are you working with protocols and need an oscilloscope to decode bus activity and correlate it with system behavior? Use the Trigger and Decode Software Bundle to trigger on key protocol events and decode raw waveforms into readable packets, frames, addresses, commands, data fields, CRCs, and errors. Search long acquisitions for specific messages, errors, addresses, or transactions while measuring timing parameters such as setup/hold time, skew, bit timing, frame timing, and bus turnaround time. Correlate multiple buses and system signals to identify whether failures are caused by protocol errors, timing violations, poor signal quality, reflections, crosstalk, termination issues, or other system-level events.

The MXO trigger and decode software application bundle includes the following SW options: MXOx-K520 (Automotive protocols),, MXOx-K530 (Aerospace protocols), MXOx-K560 (Automotive ethernet protocols), MXOx-K570 (USB protocols), MXOx-K580 (MIPI high-speed protocols), MXOx-B6 (Arbitrary waveform generator), MXOx-K510 (Low-speed serial buses), MXOx-K550 (MIPI low-speed serial buses), MXOx-K500 (Bus analysis) and MXO3-B105 or MXO4-B108 or MXO5-B110 (Memory extension option, offered option depends on the oscilloscope)

기능 및 장점

Trigger on and decode on over 30 Protocols

Trigger on and decode following protocols: I2C, SPI, RS-232, RS-422, RS-485, UART, Quad-SPI, OctoSPI, NRZ clocked, NRZ unclocked, Manchester, 8b/10b*, SPMI, RFFE, I3C, CAN, CAN FD, CAN XL, LIN, SENT, ARINC 429, MIL-STD-1553, SpaceWire, 10BASE-T1S, 100BASE-T1*,1000BASE-T1*, USB 1.1, USB 2.0, MIPI D-PHY, including CSI-2 and DSI. Audio protocols (I2S, LJ, RJ and TDM) will be added in Q1 2027. (*only on MXO5/5C)

Show me more details

Benefit from deep memory

Deep memory allows longer acquisitions, making it easier to capture rare protocol events and view extended system behavior.

Show me more details

Protocol payload interpreter

Use protocol payload interpretation to translate decoded packets into user application terminology, making protocol analysis easier to understand and communicate.

Show me more details

Bus Analysis

Perform in-depth analysis of decoded bus data using timing, measurement, and search tools.

Show me more details

사용 가능한 모델

정보 요청

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.
For service/support requests, please go here to log in or register.

마케팅 동의

신청하신 내용이 제출되었습니다. 빠른 시일 내 회신 받으실 것입니다.
An error is occurred, please try it again later.
일반 정보 및 법정 정보

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.