R&S®PAM-N analysis oscilloscope software

General Analysis

R&S®PAM-N analysis oscilloscope software
Open Lightbox
R&S®PAM-N analysis oscilloscope software
Open Lightbox
R&S®PAM-N analysis oscilloscope software, Software R&S®PAM-N analysis oscilloscope software, Screenshot

Key facts

  • Selectable PAM order from 2 to 8
  • Automatic PAM level detection
  • PAM enabled eye analysis, incl. HW-CDR
  • PAM enabled jitter & noise decomposition

Brief description

The PAM-N analysis option enables measurements on signals up to PAM-8 order. With the option installed, the R&S®RTP and RTO6 oscilloscopes offer additional PAM-N analysis capabilities within automated measurements, advanced eye as well as jitter and noise analysis.

Features & benefits

Easy signal configuration

Up to PAM-8 

The PAM-N analysis option enables measurements on signals up to PAM-8 order.  For easy signal configuration, select a respective interface standard in the Signal Configurator. For advanced customization, use the full control for the definition of signal levels and reference levels for all PAM levels and transitions.
 

Signal configurator: full control of signal and reference levels for PAM signals up to PAM-8
Open Lightbox

Signal configurator: full control of signal and reference levels for PAM signals up to PAM-8

Jitter and noise decomposition on dedicated PAM levels

Verify specific transitions and levels

The PAM option enables additional functionality for jitter
and noise analysis. With the PAM enabled SW-CDR, jitter
and noise decomposition becomes available for the various
PAM signal components. For in-depth analysis dedicated
jitter and noise components can be selected for
defined base and target PAM levels.

PAM level specific Jitter result selection
Open Lightbox

PAM level specific Jitter result selection

Advance Eye Analysis on PAM Signals

Define the focus

With activated PAM option, also PAM-N eye mask tests and eye measurements become available. Dedicated transitions and eye levels can be defined for the individual eye measurements. For the actual eye diagram, the user can choose between "whole eye", "specific eye" and "selected eye" filter mode.

PAM eye diagram displays with different filters on: "Whole eye", "Specific eye", "Selected eye".
Open Lightbox

PAM eye diagram displays with different filters on: "Whole eye", "Specific eye", "Selected eye".

Configurable HW-based CDR

"Live Eye" on PAM signals

For live-eye analysis, the R&S®RTP features a unique
HW-CDR that supports also PAM signals with a maximum
symbol rate of 3.8 GBaud/s. Benefit from the fast acquisition rate and contiously running CDR to validate signal quality over a long time or capture rare signal faults reliable.

Open Lightbox

"Live Eye" of 5GBase-T1 PAM4 signal, triggered by the RTP's configurable HW-CDR

Available models

Available models
Models
PAM order
HW-CDR
Base unit

R&S®RTP-K135

Order number 1803.6861.02

PAM order
2-8
HW-CDR
up to 3.8 Gbaud/s
Base unit

R&S®RTO6-K135

Order number 1801.8050.02

PAM order
2-8
HW-CDR
not supported
Base unit

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing permission

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.