120 Results
I would like to connect a controller with EMC32 program and measure the disturbance field strength with at a certain distance in sync with motorised rail. I would like to setup the communication between my controller and EMC32. Can you send me some instructions for communication between EMC32 and external hardware?
We are performing EMS Tests and we need live data of frequency and level. The two values are to be read out from EMC32 and transferred to Vector CANoe, the intention is to synchronize with the corresponding values for frequency and level. Are there any ready to use tools available, to read the required data from EMC32?
FAQ; EMC32 and CANoe Application
I am existing EMC32 customer. It is possible to migrate my EMC32 templates to ELEKTRA?
We have installed our test system with EMC32 and all devices, but NRP2 can not be set to physical from EMC32 using LAN interface.
EMC32 does not start - found Error 2113 in the logfile
error message EMC32: EMC32.ini is missing
EMC32, import Result Table from another PC for comparison
Configuring Maturo Type Antenna Controllers and Similar Devices in EMC32
EMC32 file access control, synchronize network server contents automatically
EMC32, add CDNE Coupling-/ Decoupling Network for EMI measurements
FAQ, Creating Scan Tables with up to four detectors using EMC32
Initialize RF Generator, change start level for immunity testing using EMC32
EMC32: EUT Monitoring, use of the Device "Evaluation"
FAQ; Answer of External Monitoring Software does not Appear in EMC32 Window. What may be the problem ?
EMC32 with Angle Offset for the second Antenna Mast
EMC32 Generic Amplifier, different ways to send SCPI commands in sequence
Learn how to solve the issue in case you get the error message "Application will be closed" from EMC32 Main Startup.
Add Limit Line to existing EMC32 Test to create a new list of critical frequencies
EMCAN32 (up to EMC32 V10.35) no connection to CANoe 9
FAQ; Why do I see only one Result Table in the EMC32 Explorer although I set two Detectors?
FAQ; Every time when I start my EMC32, a strange error appears: "ikey for AMS32 could not be found". What to do ?
After calibration I received updated attenuation and transducer tables. How do I enter these values into the EMC32 Explorer to continue new Tests with these values?
EMC32: Interactive data reduction, difference between "After data reduction" and "Before final measurements".
EMC32: How does the Standard Report refer to measurements in the semi-anechoic chambers?
FAQ: Check EMC32 Expansions
EMC32, Download Transducer Factor to Test Receiver
Immunity level not reached - abort EMS scan
EMC32 measurements with more than 1000000 points
What can I do to set up a valid transducer?